Page 1¶
Product Information¶
| Product name | Product number |
|---|---|
| Basic Software Package for ND-5000 ES Systems | 380799B |
Description of Product¶
Basic Software Package for ND-5000 ES (ND 380799) is a part of the Basic System Package for ND-5000 ES (ND 211731), which is a prepackaged system for the ND-5000 ES with menu-oriented operation routines for easy operation. It is also part of the Basic System Upgrade Kit (upgrading from version A to version B of the System Package), ND 211730.
Reason(s) for New Product or Version¶
This product is meant to be used together with one of the platform kits. All the software in this product is prepacked and ready for installation. This product will be installed and prepared by ND on all deliveries of the ND-5000 ES models.
Table of Contents¶
| Page | |
|---|---|
| 1 Prerequisites | 2 |
| 2 Dependencies | 3 |
| 3 Documentation | 3 |
| 4 Read this first | 4 |
| 5 Manual installation procedure | 5 |
| 6 Errors corrected | 12 |
| 7 Errors known but not corrected | 12 |
| 8 Limitations | 13 |
| 9 Products included | 14 |
| 10 General Information | 15 |
| 11 Creating and customising a NOTIS-DS version E archive | 20 |
| 12 Products using Software Key | 25 |
Page 2¶
Product Information¶
Product Name
Basic Software Package for ND-5000 ES Systems
Product Number
380799B
1 Prerequisites¶
The following are required in order to use this product.
Hardware Prerequisites:¶
- One of the following platform kits:
- ND 110966: Platform Kit 1 for ND-5000 Large Cabinet
- ND 110967: Platform Kit 2 for ND-5000 Large Cabinet
- ND 111194: Platform Kit for ND-5000 ES Compact
- ND 111195: Platform Kit for ND-5000 ES Satellite
- ND 111196: Platform Kit for ND-5000 Compact models A and B
- Or one of the ND-5000 ES basic models:
- ND 111178: ND-5400 ES (model S11)
- ND 111179: ND-5500 ES (model S11)
- ND 111180: ND-5700 ES (model S11)
- ND 111347: ND-5700 ES (model S11-II)
- ND 111280: ND-5830 ES (model S11)
- ND 111281: ND-5830 ES (model S11)
- ND 111283: ND-5400 ES (model C11)
- ND 111184: ND-5500 ES (model C11)
- ND 111185: ND-5700 ES (model C11)
- ND 111348: ND-5700 ES (model C11-II)
- ND 111186: ND-5800 ES (model C11)
- ND 111282: ND-5830 ES (model C11)
- ND 111283: ND-5850 ES (model C11)
- ND 111298: ND-5700 ES (model L11)
- ND 111349: ND-5700 ES (model L11-II)
- ND 111188: ND-5800 ES (model L11)
- ND 111284: ND-5830 ES (model L11)
- ND 111285: ND-5850 ES (model L11)
- ND 111189: ND-5900 ES (model L12)
- ND 111190: ND-5900 ES (model L13)
- ND 111191: ND-5900 ES (model L14)
- ND 111286: ND-5950 ES (model L12)
- ND 111287: ND-5950 ES (model L13)
- ND 111288: ND-5950 ES (model L14)
- Three empty Streamer Cassettes for use during installation. In addition, you should take an extra backup of the old version of the system disk (PACK-BASIC and PACK-MAIN-SW) before starting installation.
Software Prerequisites:¶
- If upgrading from an old version of the System Package:
Basic Software Package for ND-5000 ES Systems version A (ND 211731A)
ND-895560 EN 2
Page 3¶
Product Information¶
Product Name
Basic Software Package for ND-5000 ES Systems
Product Number
380799B
Space Requirements¶
- If upgrading from an old version of the System Package:
User area SYSTEM must have free space for 10 files using 200 pages during installation.
Dependencies¶
The system disk must be divided into four subunits (DISC-4-SCSI-1), each with the directory size 77 Mbyte.
Documentation¶
There is one manual for the ND-5000 ES which describes different operation parts supported by a menu system, and how to maintain these operation parts. Other relevant documentation for the product elements is included in the total delivery of the product (ND-870217 Basic Documentation Package for ND-5000 ES).
The most important operation documentation:
| Document | Number |
|---|---|
| ND-5000 ES System Administrator Guide | ND-830147.2 |
| DOMINO SCSI Operator Guide | ND-814009.1 EN |
| COSMOS Operator Guide | ND-830025.2 EN |
| OEM User Guide | ND-830101.1 EN |
| SINTRAN III Commands Reference Manual | ND-860128.7 EN |
| COSMOS User Guide | ND-860163.4 |
| User Environment Reference Manual | ND-860194.4 EN |
| File Manager Introduction | ND-860215.1 |
| Backup User Guide | ND-860250.2 |
| SPRINT User Guide | ND-860252.2 |
| Backup Manager User Guide | ND-860276.2 EN |
| ND-LINKER User Guide and Reference Manual | ND-860289.2 EN |
| File System Verification User Guide | ND-860354.1 |
| User Area Manager User Guide | ND-860357.1 |
| COSMOS User Card | ND-899001.2 EN |
| COSMOS Operator Card | ND-899002.2 EN |
| SINTRAN III Quick Reference Card | ND-899020.2 EN |
ND-895560 EN 2
Scanned by Jonny Oddene for Sintran Data © 2023
Page 4¶
Product Information¶
Product name
Basic Software Package for ND-5000 ES Systems
Product number
380799B
4 Read This First¶
The ES platform consists of four directories, all placed on the system disk:
PACK-BASIC -----> DISC-4-SCSI-1,0,0
PACK-MAIN-SW -----> DISC-4-SCSI-1,0,1
PACK-EXTENSION -----> DISC-4-SCSI-1,0,2
PACK-APPLICATION -----> DISC-4-SCSI-1,0,3
a) PACK-BASIC contains system files and must remain as it is when delivered from NORSK DATA A.S. Some few exceptions exist.
b) PACK-MAIN-SW contains configuration files for the system and customer-defined users.
c) PACK-EXTENSION contains your additional ND applications not included as standard on the platform.
d) PACK-APPLICATION is reserved for the different business units belonging to NORSK DATA, and their application packages.
NOTE!
The Basic Software Package for ND-5000 ES Systems is delivered as an
integrated suite of products in versions not supported separately.
Copying products separately from the Basic Software Package onto other
systems is therefore not permitted.
Likewise, installing new versions of this software separately
(except SINTRAN III as described in chapter 10), is not permitted and
is not supported by Norsk Data.
ND-895560 EN 2
Page 5¶
Product Information¶
| Date | Page |
|---|---|
| 90.11.28 | 5 of 25 |
| Norsk Data | |
Product Name¶
Basic Software Package for ND-5000 ES Systems
| Product Number |
|---|
| 380799B |
5 Manual Installation Procedure¶
This procedure should be followed when a new version of the Basic System Package is to be installed as part of upgrading from an older version.
CAUTION!
All software located on PACK-BASIC will be destroyed and a new version of PACK-BASIC will be restored from the streamer. On user area SYSTEM there may be files belonging to products other than those listed in chapter 10 (libraries, init files etc.). Backup of these files must be taken before the disk is restored.
1. Preparations Before Stopping the ND-5000 ES:¶
a. Perform a controlled shutdown of the ND-5000 ES:
Log in to user area SYSTEM and execute the command:
@MODE (MODE-FILES)SYSTEM-SHUTDOWN:MODE
All configuration-dependent system files located on PACK-BASIC will be copied to user CONFIG-FILES on PACK-MAIN-SW.
b. Execute the command @LIST-TITLE,... and note the CPU number and type. You may be asked for it later in the installation procedure.
c. Check that the file (MODE-FILES)DEF-PERIPHERALS:MODE corresponds to your system.
ND-895560 EN 2
Page 6¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.11.28 | 6 of 25 |
Product name Basic Software Package for ND-5000 ES Systems
Product number 380799B
Instructions¶
d. Take a complete backup of PACK-BASIC and PACK-MAIN-SW using the Backup Manager:¶
-
Insert streamer cassette number one into the drive.
- Log in as user area SYSTEM and start the BACKUP-MANAGER from the ND-5000 ES System Administrator menu option 3.0 (backup) or from SINTRAN by giving the command
@BM-OPERATOR-.
BmOp: BACKUP START Give set name: BACK-PACK-BASIC - Log in as user area SYSTEM and start the BACKUP-MANAGER from the ND-5000 ES System Administrator menu option 3.0 (backup) or from SINTRAN by giving the command
-
Insert streamer cassette number two into the streamer drive.
- Log in as user area SYSTEM and start the BACKUP-MANAGER from the ND-5000 ES System Administrator menu option 3.0 (backup) or from SINTRAN by giving the command
@BM-OPERATOR-.
BmOp: BACKUP START Give set name: BACK-PACK-MAIN - Log in as user area SYSTEM and start the BACKUP-MANAGER from the ND-5000 ES System Administrator menu option 3.0 (backup) or from SINTRAN by giving the command
e. Install the auxiliary files supplied with the Software Package:¶
Insert the diskette in the floppy drive and enter the directory on the floppy. Copy all the files to user area SYSTEM and release the floppy:
@ENTER-DIRECTORY_FLOPPY-DISC-<controller-no.>,<floppy-unit>~
@BACKUP-SYSTEM~
Ba-sy: COPY~
Destination type: DIRECTORY~
Destination directory name: ~
Destination user name 'SYSTEM': ~
Source type: DIRECTORY~
Source directory name: 380941~
Source user name 'SYSTEM?': ~
Source file name '': ~
Manual selection: N~
Ba-sy: EXIT~
@RELEASE-DIRECTORY,ND~
f. Run the program COPY-USERS:¶
@COPY-USERS~
ND-895560 EN 2
Page 7¶
Product Information¶
| Date | Page |
|---|---|
| 90.11.28 | 7 of 25 |
| Norsk Data |
|---|
| Product Information |
| Product Name | Product Number |
|---|---|
| Basic Software Package for ND-5000 ES Systems | 380799B |
Verification¶
g. Run the mode file to verify the old User Environment database:
@MODE UE-VERIFY:MODE,_
Backup Manager Instructions¶
h. Save user files to 3 empty streamer cassettes using the BACKUP MANAGER:
-
Insert streamer cassette number one into the drive.
- Log in as user area SYSTEM and start the BACKUP-MANAGER from the ND-5000 ES System Administrator menu option 3.0 (backup) or from SINTRAN by giving the command
@BM-OPERATOR.
BmOp: COPY Object Copy method Incremental SINTRAN SELECTION FILE NO From Computer name Directory name User area Control DIRECTORY PACK-BASIC To Volume name Computer name Device name Ü S Mode VOLUME EXCL-PACK-BASIC STREAMER-1 0 Nc.Ov Selection Selection file name EXCLUDE (SYSTEM)ES-EXCLUDE-FILES:SYMB Select execution mode (Manual/Stop-on-Error/Automatic): Stop-on-Err- All files and users NOT listed in the (SYSTEM)EXCLUDE-FILES:SYMB file, will be copied to the streamer cassette.
- Log in as user area SYSTEM and start the BACKUP-MANAGER from the ND-5000 ES System Administrator menu option 3.0 (backup) or from SINTRAN by giving the command
-
Insert streamer cassette number two into the streamer drive.
- Log in as user area SYSTEM and start the BACKUP-MANAGER from the ND-5000 ES System Administrator menu option 3.0 (backup) or from SINTRAN by giving the command
@BM-OPERATOR.
BmOp: COPY Object Copy method Incremental SINTRAN SELECTION FILE NO From Computer name Directory name User area Control DIRECTORY PACK-MAIN-SW To Volume name Computer name Device name Ü S Mode VOLUME INCL-PACK-MAIN STREAMER-1 0 Nc.Ov Selection Selection file name INCLUDE SYSTEM)ES-IN-PA-MA:SYMB Select execution mode (Manual/Stop-on-Error/Automatic): Stop-on-Err - Log in as user area SYSTEM and start the BACKUP-MANAGER from the ND-5000 ES System Administrator menu option 3.0 (backup) or from SINTRAN by giving the command
ND-895560 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2023.]
Page 8¶
Product Information¶
Product name: Basic Software Package for ND-5000 ES Systems
Product number: 380799B
- Insert streamer cassette number three into the streamer drive.
- Log in as user area SYSTEM and start the BACKUP-MANAGER from the ND-5000 ES System Administrator menu option 3.0 (backup) or from SINTRAN by giving the command
@BM-OPERATOR-.
BmOp: COPY
Object Copy method Incremental
SINTRAN SELECTION FILE NO
From Computer name Directory name User area Control
DIRECTORY PACK-MAIN-SW
To Volume name Computer name Device name S Mode
VOLUME EXCL-PACK-MAIN STREAMER-1 0 - Nc.Ov
Selection Selection file name
EXCLUDE (SYSTEM)ES-EX-PA-MA:SYMB
Select execution mode (Manual/Stop-on-Error/Automatic): Stop-on-Err
i. Passwords
Write down the following passwords:
- SYSTEM (SINTRAN password)
- SIBAS-MANAGER (User-Environment password)
2. Stop the ND-5000 ES¶
Press the STOP and MACL (Master Clear) buttons from the operator panel.
ND-895560 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2023]
Page 9¶
Product Information¶
| Date | Page |
|---|---|
| 90.11.28 | 9 of 25 |
| Product name | Product number |
|---|---|
| Basic Software Package for ND-5000 ES Systems | 380799B |
3. Install the New Platform¶
Insert the Disk Restore (ND 211187B) diskette number 1 in the main floppy driver and type I560& (without pressing carriage return). Follow the instructions given to read diskettes nos. 2 and 3.
Insert the ND 380799B streamer cassette in the streamer drive.
Copy the streamer cassette to the system disk (device: DISC-4-SCSI-1 unit: 0 subunit: 0).
- Di-Re: RESTORE-DISK
From (Directory/Volume) : VOLUME
Source device name : STREAMER-1
Source device unit : 0
Retension (Yes/No) : YES
Compare (Yes/No) : YES
Destination device name : DISC-4-SCSI-1
Destination device unit : 0
Destination device subunit : 0
Retension
Mounted volume is: ES-PLATFORM on device: STREAMER-1,0
Give command (Continue/Retry/Cancel) : CONTINUE
Searching
---------------- Image found -------------------------
Volume : ES-PLATFORM
Reel : 1
Index : 1
Computer :
Directory : PACK-BASIC-B
Device : DISC-4-SCSI-1,0,0
Pages : 37685
Backed up : 90-11-23
Control : RdFc
------------------------------------------------------
Confirm start of restore (Start/Next-Image/Cancel) : START
Directory: PACK-BASIC-A
detected on the device: DISC-4-SCSI-1,0,0
Give command (Retry/Overwrite/Cancel): OVERWRITE
Copying (DMA)
Rewinding
Comparing
This takes about 22 minutes with compare.
When this operation has finished, continue with next point.
ND-895560 EN 2
Page 10¶
Product Information¶
Date: 90.11.28
Company: Norsk Data
Page: 10 of 25
Product Details¶
| Product Name | Product Number |
|---|---|
| Basic Software Package for ND-5000 ES Systems | 380799B |
Instructions¶
-
Di-Re:
RESTORE-DISK- From (Directory/Volume):
VOLUME - Source device name:
STREAMER-1 - Source device unit:
0 - Retension (Yes/No):
YES - Compare (Yes/No):
YES - Destination device name:
DISC-4-SCSI-1 - Destination device unit:
0 - Destination device subunit:
1 - Retension
- Mounted volume is:
ES-PLATFORMon device:STREAMER-1,0 - Give command (Continue/Retry/Cancel):
CONTINUE
Searching
---------------- Image found ----------------
Attribute Value Volume ES-PLATFORM Reel 1 Index 1 Computer Directory PACK-BASIC-B Device DISC-4-SCSI-1,0,0 Pages 37685 Backed up 90-11-23 Control RdFc
Confirm start of restore (Start/Next-Image/Cancel):
NEXT-IMAGESearching
---------------- Image found ----------------
Attribute Value Volume ES-PLATFORM Reel 1 Index 1 Computer Directory PACK-MAIN-SW Device DISC-4-SCSI-1,0,1 Pages 37685 Backed up 90-11-23 Control RdFc
Confirm start of restore (Start/Next-Image/Cancel):
STARTDirectory:
PACK-MAIN-SW
Detected on the device:DISC-4-SCSI-1,0,1
Give command (Retry/Overwrite/Cancel):OVERWRITE- Copying (DMA)
- Rewinding
- Comparing
- From (Directory/Volume):
This takes about 22 minutes with compare.
When this operation has finished, remove the streamer cassette and continue with the next point.
ND-895560 EN 2
Page 11¶
Product Information¶
| Date | Norsk Data | Page 11 of 25 |
|---|---|---|
| Product name | Product number | |
| Basic Software Package for ND-5000 ES Systems | 380799B |
4. Initialising the New Platform:¶
Press the MCL (Master Clear) and the LOAD buttons on the Operator panel.
The system will then start (this takes about 5 minutes) and the following text will appear on the terminal:
--------------------------------------------------
! All configuration-dependent files are now reinstalled !
! !
! Please continue with next point in the installation !
! procedure in the PI sheet. !
--------------------------------------------------
Customise the new platform:
a) Platform Preparations¶
Log in as user area SYSTEM and start the installation program @PLATFORM-INST~
Answer the questions according to the software and hardware configuration on your system.
The installation program will now prepare the system according to your specifications.
b) Do a Warm Start: @RESTART-SYSTEM~¶
The system is now running through a complete cold start and warm start (this takes about 15 minutes).
When the system has been restarted, the following text is displayed on the console printer and on the console:
>> The ND-5000 ES is available
c) Swap File Configuration¶
This system has only one swap file with a size of 2000 pages. This means that before the system is taken into use you must define a swap file on a "non-platform" directory.
-
@CREATE-FILE (<directory name>:<user name>)swap-file-1:swap,<size>~ -
@ND~DELETE-SWAP-FILE (<directory name>:<user name>)SWAP-FILE-1:SWAP~DEFINE-SWAP-FILE (<directory name>:<user name>)SWAP-FILE-1:SWAP~EXIT~
Point 2. above must also be put into the file USER-DISKS:MODE
@PED-E (MODE-FILES)USER-DISKS:MODE~
ND-895560 EN 2
Page 12¶
Product Information¶
| Date | Norsk Data | Page 12 of 25 |
|---|---|---|
| 90.11.28 | PRODUCT INFORMATION |
| Product name | Product number |
|---|---|
| Basic Software Package for ND-5000 ES Systems | 380799B |
The installation of the basic platform is now complete and ready to operate with a new version of the basic software.
CAUTION!¶
Remember to take a complete backup of the System disk PACK-BASIC, PACK-MAIN-SW, PACK-EXTENSION and PACK-APPLICATION (PACK-APPLICATION is optional).
This is for security reasons in case of disk problems later on.
6 Errors Corrected¶
All reported errors have been corrected.
7 Errors Known But Not Corrected¶
-
SPRINT SINTRAN Spooling System (ND 211056 A05)
If on startup of SPRINT, device numbers 1032-1039 (and maybe others) are being used, SPRINT will not be able to stop the SPRT programs which have reserved these device numbers. Consequently, SPRINT will not be able to use the associated printers.
-
BACKUP Manager (ND 211226 B04)
- RESTART-USER in the menu has not been fully corrected. It is not possible to do this against a remote server.
- Problems with treating EOF-status as OK after 'space-EOF' function. This is a problem for non-SCSI magnetic-tape drives when listing volumes spanning more than one tape.
ND-895560 EN 2
Scanned by Jonny Oddene for Sintran Data © 2023
Page 13¶
Product Information¶
| Date | Norsk Data | Page 13 of 25 |
|---|---|---|
| 90.11.28 |
| Product name | Product number |
|---|---|
| Basic Software Package for ND-5000 ES Systems | 380799B |
8 Limitations¶
- BACKUP Manager (ND 211226 B04)
- Indexed files larger than 65000 pages cannot be copied by Backup Manager (contiguous files can be copied when logged in as user area SYSTEM!)
- When performing image copying in batch mode (for example, via BM-scheduler), you cannot copy the directory where the input and output batch files for this job are located (normally the directory where user areas SYSTEM and ND-OPERATIONS are located).
- You cannot copy TO a DOMINO/SCSI tape device from a remote computer.
- Image backup from ND-100 disks to tape/GTS devices connected to DSS is not possible.
ND-895560 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2023]
Page 14¶
Product Information¶
| Date | Norsk Data |
|---|---|
| 90.11.28 | Page 14 of 25 |
Product Name¶
Basic Software Package for ND-5000 ES Systems
| Product Number |
|---|
| 380799B |
9 Products Included¶
| NDno./Version | Software Module | SINTRAN User |
|---|---|---|
| 250304 M06 | SINTRAN III/VSX-500 Standard system A | SYSTEM |
| 250360 M06 | SINTRAN III/VSX Patch File 4200 | SYSTEM |
| 210124 E01 | SINTRAN III Configuration program | SYSTEM |
| 210913 C00 | SINTRAN III Monitor Call Package | SYSTEM |
| 211846 A02 | SOFTICE for SINTRAN Systems | SYSTEM |
| 211305 C03 | ND-500/5000 System Package for SINTRAN III/VSX version M | BASIC-FILES |
| K01 ND-500/5000 Background Monitor | BASIC-FILES | |
| L02 ND-500/5000 Swapper | SYSTEM | |
| C01 ND-500/5000 Place Library | SYSTEM | |
| 210534 B00 | JEC | SYSTEM |
| 210721 C01 | BRF-Linker | BASIC-FILES |
| 210375 C05 | TELEFIX files for user sites | BASIC-FILES |
| 210337 I05 | Backup-System | BASIC-FILES |
| 210455 G06 | VTM Tables | SYSTEM |
| 210139 H02 | ND-500 Linkage-Loader | BASIC-FILES |
| 210511 D02 | ND-500 Exception Library | SYSTEM |
| 210080 J00 | PED for ND-100 (English) | SYSTEM |
| 210530 K02 | PED for ND-500 (English) | BASIC-FILES |
| 211224 B01 | ND Linker for ND-500/5000 | BASIC-FILES |
| 211229 A03 | Convert-Domain | BASIC-FILES |
| 211322 C03 | DOMINO Maintenance kit | TEST-USER |
| 211321 C03 | NUCLEUS Maintenance kit | TEST-USER |
| 211479 A09 | DSS Basic System | SCSI-DOMINO |
| 211480 A09 | DSS Libraries | SCSI-DOMINO |
| 211481 A06 | DSS Test programs | TEST-USER |
| 210335 H00 | Symbolic Debugger for ND-500/5000 | SYSTEM |
| 210336 F01 | Symbolic Debugger for ND-100 | SYSTEM |
| 211226 B04 | Backup Manager | BACKUP-MANAGER |
| 210374 G02 | COSMOS Basic Module | BASIC-FILES |
| 210580 B04 | COSMOS Ethernet option | BASIC-FILES |
| 211075 C03 | File Manager | OE-USER |
| 211073 A05 | File System Verification | OE-USER |
| 211070 A01 | User Area Manager | OE-USER |
| 211078 A01 | Multi-Machine Operator Environment | OE-USER |
| 211074 B01 | Performance Monitor for ND-100/500/5000 | OE-USER |
| 211056 A05A | SPRINT Spooling System | SPRINT-USER |
ND-895560 EN 2
Page 15¶
Product Information¶
| Date | Norsk Data | Page 15 of 25 |
|---|---|---|
| Product Information |
| Product name | Product number |
|---|---|
| Basic Software Package for ND-5000 ES Systems | 380799B |
10 General Information¶
-
DSS Basic System (ND 211479 A09)
-
Device parameters should be set with DP-SERVICE for some devices.
Command: CHANGE-PARAMETERS
These are:
- CDC disks: Device settle time = 10 seconds
- Device power uptime = 90 seconds
- GTS, STC tapes: No synchronous transfer
- GTS tapes: No. of retries on aborted command = 0
- GTS tapes: Abort command allowed = NO
Remember also when defining the device GTS that the device code = 1.
-
-
SINTRAN III patches
When it is necessary to install SINTRAN from floppies.
In addition to the patch file 4200, the file (SYSTEM)SINTRAN-PATCHES:MODE must be run as a mode job after the standard patch file.
This file includes additional patches for SINTRAN that are NOT included in the patch file 4200.
When a new SINTRAN with patches is installed, do the following:
- @COLD-START
-
Log in and enter the main directory by typing:
@ENTER-DIRECTORY,,DISC-4-SCSI-1,0,0
- Log out and log in as user area SYSTEM
@SINTRAN-SERVICE @SET-COLDSTART-MODE-FILE PACK-BASIC-B,DISC-4-SCSI-1,0,0 @HENT-MODE:MODE @HENT-OUTPUT:LIST @EXIT @S3-CONFIG GENERATE @COLD-START
ND-895560 EN 2
Page 16¶
Product Information¶
| Date | Norsk Data | Page 16 of 25 |
|---|---|---|
| Date 90.11.28 | Product Information | |
| Product name | Basic Software Package for ND-5000 ES Systems | Product number |
| 380799B |
Special Modification Patches (SM-patches)¶
SM-patches are patches for customers with special needs (the different SM-patches for SINTRAN version M are listed below).
How to Implement¶
-
Edit in the right patch number in the file
PF-MODIF-M:FADMon user area SYSTEM. -
Run the mode job
(SPEC-MODIF-PATCH)SM-START-PATCH-FILE:MODE @MODE (SPEC-MODIF-PATCH)SM-START-PATCH-FILE:MODE -
Run through a SHUTDOWN procedure and do a
@COLD-START
Example of what a PF-MODIF:FADM file looks like¶
PN032 %Here the SM-patch 032 is implemented
@
List of SM-patches available on SINTRAN III/VSX version M:¶
PN032
PN034
PN035
PN036
PN043
PN067
PN068
PN069
PN070
PN072
PN073
PN074
PN075
PN076
PN077
PN078
PN079
ND-895560 EN 2
Page 17¶
Product Information¶
| Date | Norsk Data | Page 17 of 25 |
|---|---|---|
| 90.11.28 |
Product Name¶
Basic Software Package for ND-5000 ES Systems
Product Number¶
380799B
- SPRINT SINTRAN Spooling System (ND 211056 A05)
- SPRINT will not accept documents stored under NOTIS-DS. Such documents must be moved to SINTRAN if they are to be printed.
- If remote printing is to be successful, the SSYOPEN routine in the SSYLIB library requires that the local system name corresponds to the first system name defined on the remote machine.
Installation of a New Printer Driver in SPRINT¶
The following SPRINT drivers could be installed from the disk:
Not Handling Open Lan¶
- PHILIPS-300
- DP-55
- EPSON-MX80
- EPSON-RX80
- DIABLO-1650
- DIABLO-1610
- DIABLO-630
- TEC-F10
- OLIVETTI
- GEN-3024
- EPSON-LX80
- ELPHO-20
- LINE-PRINTER
- TELEX
- CANON-LBP8
Handling Open Lan¶
- EPSON-MX80
- EPSON-RX80
- EPSON-LX80
- ND-616cn
- ND-720PP
- ND-460TTP
- ND-PSCRIPT
- PHILIPS-300
- CANON-LBP8
- LINE-PRINTER
- VISION SERVER
To start the installation program, log into user area SYSTEM and give the command:
@(SPRINT-USER)IN-PRM
The rest of the procedure is self-explanatory.
If a printer driver is going to be installed from a diskette, the installation program has to be started from the diskette containing the printer driver and the installation program.
When you are asked where to put the new printer driver(s), the user name must be SPRINT-USER (default answer is ND-OPERATIONS).
ND-895560 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2023]
Page 18¶
Product Information¶
Product Name:
Basic Software Package for ND-5000 ES Systems
Product Number:
380799B
Redefining OpenLAN-Printers¶
When you have installed a new platform on your system:
-
From user area SYSTEM, use an editor to read the file:
SYMBOL-2-LIST:SYMB- Find the text string FI731
- Write down the value corresponding to FI731 (on most systems the address will be 072162)
-
@ABORT COSPO -
Exit the editor and type the following underlined text after the SINTRAN prompt:
SINTRAN-SERVICE-PROGRAM~
*INSERT-IN-LOGICAL-UNIT-TABLE~
LOGICAL UNIT NUMBER (OCT):23xx~
(23xx is the SINTRAN logical device number in octal from S3-CONFIG)
INPUT OR OUTPUT? OUT~
DATAFIELD ADDRESS (OCT):fffff~
(fffff is the data field address from step 1. above)
MEMORY? YES~
IMAGE? YES~
SAVE-AREA? YES~
*EXIT~
- Type the following underlined text:
@SET-PERIPHERAL-FILE "<name>" <23xx>~
@SET-FILE-ACCESS <name> WA RWA RWA~
@CREATE-NEW-VERSION <name>:;x,0~
(x is the number of spooling files)
@SET-FILE-ACCESS <NAME>:;1..,RWACD~
Remember to include these four lines in your DEFINE-PERIPHERALS file as well.
-
Steps 3. and 4. must be executed for each OpenLAN-printer on your system.
-
@SPRINT /START-SPRINT -
@START-SPOOLING COSMOS-SPOOLING
ND-895560 EN 2
Page 19¶
Product Information¶
| Date | Norsk Data | Page 19 of 25 |
|---|---|---|
| Product name | Product number | 380799B |
Basic Software Package for ND-5000 ES Systems
ND-5000 ES System Administrator Menu System¶
On this platform, you may have the ND-5000 ES System Administrator Menu System in either English or Norwegian. To change from Norwegian to English, or the other way around, you should do as follows:
- Log into UE-user SYSTEM.
- Start the User Environment profile manager by typing
@UE-PMAN. - Type SYSTEM when you are asked for user name.
- Further down in the same menu, you are asked for language.
- You then type either Norwegian or English (this may be abbreviated).
- The name of the menu-system is (SYSTEM)ES-MENU.
- To get out of the menu, press the EXIT button.
Defining Extra Swap-Files and Segment-Files¶
- If you need more swap-files or segment-files, you must update two different files:
(ND-OPERATIONS)BM-PARAMETER-B:DATA(MODE-FILES)USER-DISKS:MODE
-
@PED (ND-OPERATIONS)BM-PARAMETER-B:DATAHere you insert the following:
IMAGE-NO-COMPARE-FILE = (SWAP-USER)SWAP-FILE-<x>:SWAP for extra swap file, or IMAGE-NO-COMPARE-FILE = (SWAP-USER)SEGFIL<x>:DATA for extra segment file.(SWAP-USER) = Name of the user containing the SWAP or SEGMENT file<x> = SWAP or SEGMENT file number -
@PED (MODE-FILES)USER-DISKS:MODEAt the end of this file, you insert the following:
@ND DELETE-SWAP-FILE (SWAP-USER)SWAP-FILE-<x>:SWAP DEFINE-SWAP-FILE (SWAP-USER)SWAP-FILE-<x>:SWAP EXIT
ND-895560 EN 2
Page 20¶
Product Information¶
| Date | 90.11.28 | Norsk Data | Page 20 of 25 |
|---|---|---|---|
| Product name | Basic Software Package for ND-5000 ES Systems | Product number | 380799B |
11 Creating and Customising a NOTIS-DS Version E Archive¶
If you have previously installed NOTIS-DS version D on your ND-5000 ES, you should now upgrade to the E-version.
You must then create a new (E-version) database and convert your old database using the program DS-CONVERT. The conversion takes time (6-8 Mbytes per hour). Until the conversion is completed, you need disk space to keep both databases. This chapter contains a detailed description of how to create a NOTIS-DS version E database and convert the database from version D to version E.
This chapter consists of four parts:
- Creating the NOTIS-DS version E archive
- Defining NOTIS-DS access from frontend computers
- Converting an existing NOTIS-DS version D database to NOTIS-DS version E
- After successful conversion to NOTIS-DS version E
1. Creating the NOTIS-DS Version E Database¶
NOTE!
____________________________________
| |
| This chapter does not apply if |
| you are using NOTIS-DS version E |
| already. |
| |
| It is important that you follow |
| the procedure in the order shown. |
|____________________________________|
a) Before you create your database, you must make sufficient contiguous space available for the user areas designated to hold the database files (DSBASE) and R-log file(s) (DSLOGG).
Refer to chapter 2.3 Estimating the space you need in the NOTIS-DS Supervisor Guide before you start. It gives you hints for estimating the size of the new database and a description of the program DS-DEFINE.
b) Log in as SINTRAN user area DSBASE.
Copy the file DS-DEFINE-E02:DRL from user area DS-PROGRAMS. Run the program to define the database:
@N0 (DS-PROGRAMS)DS-DEFINE-E02~
A database file should be smaller than 65000 SINTRAN pages, as this is handled by the file-as-segment method.
The program will create all database files and log files, and produce a schema file (DS-FORM:DRL) for initiation of the database.
ND-895560 EN 2
Page 21¶
Product Information¶
| Date | Norsk Data | Page 21 of 25 |
|---|---|---|
| 90.11.28 |
Product name
Basic Software Package for ND-5000 ES Systems
| Product number |
|---|
| 380799B |
c) When DS-DEFINE has run successfully, you must initiate the database for SIBAS using SIBR-DRL.
Enter SINTRAN user DSBASE and give the following commands:
@SIBR-DRL
N
N
DS-FORM:DRL
DS-FORM:LIST
Check the output on the file DS-FORM:LIST.
d) Update the file (ND-OPERATIONS)SW-CONFIG:SYMB with parameters for the NOTIS-DS database:
DATABASE-NAME = DSBASE -l % 2 spaces before -l
USER-AREA = DSBASE
DATABASE-ADMINISTRATOR = SIBAS-MANAGER
DATABASE-ADMINISTRATOR = <UE user name>
SIBAS-PROCESS = 23
AUTO-START = ON
R-LOG-LIMITS = 80,95,99.5
R-LOG-MONITORING = 5
B-LOG = YES
B-LOG-FILE-SIZE = 1000
R-LOG = DIRECT
NUMBER-OF-R-LOGS = <number of files>
R-LOG-FILE-SIZE = <file size>
R-LOG-USER-AREA = <directory>:DSLOGG % Maximum 8 characters
R-LOG-USER-AREA-n = <directory>:DSLOGG % Maximum 8 characters
HOLD-IF-FULL-R-LOG = YES
AUTO-RECOVERY = YES
HEADING = NOTIS-DS database
Documentation of SW-CONFIG:
- NOTIS-DS Supervisor Guide (ND-830059.5)
- DIALOGUE Operations (ND-830072.2)
ND-895560 EN 2
Page 22¶
Product Information¶
| Date | Norsk Data | Page 22 of 25 |
|---|---|---|
| Product name | Product number | |
| Basic Software Package for ND-5000 ES Systems | 380799B |
e) Next, the database must be prepared for use by NOTIS-DS.
Log in as SINTRAN user area DSBASE and do the following:
@LOOK-FILE←
OPEN DSBASE:DATA...←
PATCH 0 30←
IOD←
←
EXIT←
f) Log in as SINTRAN user area DSBASE and start the NOTIS-DS database using the START command in SIBAS-Service.
The first time you start the database you must use SIBAS-Service and not SIBAS-Manager because only SIBAS-Service will initialize the log files. Check that the database is running properly. To do this, use the command STATUS/One database in SIBAS-Service.
g) After the database has been started, the NOTIS-DS-hierarchy must be initialized.
Log in as SINTRAN user area DS-PROGRAMS to edit the file DS-MAKE-DB-E02:MODE.
Substitute <CPU number> with the CPU-number of your ND-5000 ES.
Log in as SINTRAN user area SYSTEM to run the job:
@MODE (DS-PROGRAMS)DS-MAKE-DB-E02:MODE...←
Then stop the database using the STOP command in SIBAS-Service.
Now, take a backup of your new database.
ND-895560 EN 2
Page 23¶
Product Information¶
| Date | Norsk Data | Page 23 of 25 |
|---|---|---|
| 90.11.28 |
| Product name | Product number |
|---|---|
| Basic Software Package for ND-5000 ES Systems | 380799B |
h) The NOTIS-DS archive must have a database password. This password should not be confused with the password of the UE user called Database administrator.
To define the database password, you must do the following BEFORE starting the database again:
Log in as SINTRAN user area DSBASE.
@SIBR-DBM~
DSBASE~
DSBASE~
~
PRIVACY/DEFINE/DBA-PASSWORD <password>~
EXIT~
i) Having been defined in the database, the database password must also be defined in NOTIS-DS.
Log in as SINTRAN user area SYSTEM and start NOTIS-DS.
Use the command ADMINISTRATION/CHANGE PASSWORD and give the same password as with SIBR-DBM.
j) To enable SIBAS-MANAGER to handle the database, you must enter information about the database and password in the file (SYSTEM)SM-DBINFO:SYMB:
k) Finally you must start the NOTIS-DS Emulator server to enable other NOTIS products (ID, WP etc.) to access the DS-archive.
Log in as SINTRAN user area SYSTEM and run the job
@MODE (DS-PROGRAMS)DS-EMSTART-EO2:MODE.,~
Your NOTIS-DS E-version archive is now available.
ND-895560 EN 2
[Scanned by Jonny Oddene for Sintran Data © 2023]
Page 24¶
Product Information¶
| Product name | Product number |
|---|---|
| Basic Software Package for ND-5000 ES Systems | 380799B |
2. Defining NOTIS-DS Access from Frontend Computers¶
a) Frontend computer with NOTIS-DS version E installed:
Log in as SINTRAN user area SYSTEM and start the NOTIS-DS.
Use the command ADMINISTRATION/CHANGE PASSWORD and give the database password as defined on the database computer.
b) Frontend computer without NOTIS-DS version E:
If a computer with NOTIS products (but not NOTIS-DS/E) needs access to a remote NOTIS-DS version E database, copy the program DS-EMSERVICE-E02:PROG manually from the ND-5000 ES to a SINTRAN user area on the computer that needs access.
Define the password using the command DEFINE-DS-SYSTEM in DS-EMSERVICE.
The command is described in the NOTIS-DS Supervisor Guide, section 6.8.
3. Converting an Existing Version D Database to Version E¶
The program DS-CONVERT converts data from a database for NOTIS-DS version D to an E-version database. You have two options:
a) Converting the whole database in one operation.
To do this nobody must be allowed to use NOTIS-DS or NOTIS-ID until the conversion is completed.
b) Converting the database in two phases.
This enables you to leave the NOTIS-DS version D archive available during most of the operation, but the conversion will take longer.
Before you start converting, you must stop the Emulator server by running:
@MODE (DS-PROGRAMS)DS-EMSTOP-E02:MODE.l
and load and start the D-version document server by running:
@MODE (NOTIS)DS-LOAD:MODE.l
@(NOTIS)DS-SERVICE
START-SERVER
SELECT-SERVER BS
START-SERVER
EXIT
The D-version document server (DsDs) and the new database must be running while you convert your database. Make sure that the E-version database is not opened by any users, and that the R-log(s) are turned OFF before the conversion is run.
The different conversion procedures are described in the NOTIS-DS Supervisor Guide, chapter 3.
Page 25¶
Product Information¶
| Date | 90.11.28 |
| Norsk Data | |
| Page | Page 25 of 25 |
| Product name | Basic Software Package for ND-5000 ES Systems |
| Product number | 380799B |
4. After Successful Conversion to NOTIS-DS Version E¶
a) Check the output from the conversion to see if the operation has been successful.
b) Stop the D-version document server(s) and the E-version database. Take a full backup of your new database. (You should also back up your old database if you have not already done so.)
c) Delete the standard domain NOTIS-DS (D-version) and define the E-version:
@ND
DEFINE-STANDARD-DOMAIN NOTIS-DS (DS-PROGRAMS)NOTIS-DS-<lan>-E
EXIT
d) You may now delete the D-version program files and domains.
e) Start the E-version database (answer Y when asked if you want to connect the R-log and Y if you want to reset the log).
f) Start the NOTIS-DS Emulator server.
g) Your NOTIS-DS archive is converted and ready for use!
12 Products Using Software Key¶
If you are installing software products using software activation keys or upgrading to a new version of such software, you must install the software activation keys required. The procedure is as follows:
@ND SOFTICE~
STORE-SOFTWARE-KEY~
Product number: nnnnnn~
Software key: xxxxxxxx~
Expiry date: yyyy.mm.dd~
Product name: ttttttt~
EXIT~
Information about product number, software key, product name, and expiry date (if any) is found on the Software Activation Key Certificates included in the delivery. Expiry date is only given if the certificate states a limited license, otherwise, it is empty.
Some relevant products are:
| Product | Certificate number |
|---|---|
| ND 220002 SIBAS/R | ND-891095EN1 |
| ND 220004 SIBAS/R Backend | ND-891096EN1 |
| ND 220005 SIBAS/R Development Access | ND-891097EN1 |
ND-895560 EN 2