Page 1¶
Product Information¶
| Product name | Product number |
|---|---|
| SIBAS Manager for ND-500/5000 | 380862A |
| Patch File |
Description of Product¶
This product contains a patch file for SIBAS Manager version A05.
Reason(s) for New Release¶
+---------------------------------------------+
| - Error corrections in SIBAS Manager |
+---------------------------------------------+
Table of Contents¶
| Contents | Page |
|---|---|
| Prerequisites | 2 |
| Dependencies | 4 |
| Documentation | 4 |
| Installation procedure | 5 |
| Modifications | 6 |
| Errors corrected | 6 |
| Errors known but not corrected | 6 |
ND-895617.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 2¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.10.15 | 2 of 6 |
| Product name | Product number |
|---|---|
| SIBAS Manager for ND-500/5000 Patch File | 380862A |
1 Prerequisites¶
The following is required in order to use this product.
1.1 Hardware Prerequisites¶
The following hardware must be present for this product to be used:
CPU type (any of the following): - 500 - 5000
Floating format: Any
Other hardware:
| Product name | Product number |
|---|---|
| None | None |
1.2 Software Prerequisites¶
The following software must be available on the system before the product is installed:
Operating system:
| Name | Version/Revision |
|---|---|
| SINTRAN-III >= L Workmode 7 | >=4000 |
ND-895617.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 3¶
Product Information¶
Date: 90.10.15
Norsk Data
Page: 3 of 6
Product Name¶
SIBAS Manager for ND-500/5000 Patch File
Product Number: 380862A
Other Software¶
Product Name¶
| Product Name | Product Number |
|---|---|
| SIBAS Manager A05 | ND-211455 A |
1.3 Other Prerequisites¶
Minimum Permanent Mass Storage:
| User | Space (pages) | Number of files |
|---|---|---|
| SIBR-B | 6 | 1 |
Minimum |
Maximum |
Number of segments (ND-100) | 0 | 0
Number of RT descriptions | 0 | 0
Space required on segment files: 0 pages
Requirements regarding internal devices:
None
Requirements regarding batch processors:
None
ND-895617.1 EN
Scanned by Jonny Oddenee for Sintran Data © 2011
Page 4¶
Product Information¶
| Date | Norsk Data | Page 4 of 6 |
|---|---|---|
| Product name | Product number | |
| SIBAS Manager for ND-500/5000 Patch File | 380862A |
2 Dependencies¶
In addition, the following dependencies exist between this and other products. The hardware and software listed here, may for example be necessary to make full use of the product.
2.1 Hardware Dependencies¶
| Product name | Product number |
|---|---|
| None | None |
2.2 Software Dependencies¶
None
2.3 Other Dependencies¶
You should also be aware of the following dependencies:
| Product name | Product number |
|---|---|
| None | None |
3 Documentation¶
Included with the product
None
Optional (must be purchased)
None
ND-895617.1 EN
Page 5¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.10.15 | 5 of 6 |
Product Name¶
SIBAS Manager for ND-500/5000 Patch File
Product Number¶
380862A
4 Installation Procedure¶
4.1 Automatic Installation¶
None
4.2 Non-Automatic Installation¶
- Before you start installing the patch file, check that SIBAS Manager A05 is installed and passive, and not defined as standard domain.
Log in as user: SYSTEM
@ND-
LIST-STANDARD-DOMAINS-
DELETE-STANDARD-DOMAIN SIBAS-MANAGER-A05-
EXIT-
- Log in as user:
SIBR-B
- Insert the floppy 380862A05-XX-01D in floppy drive 0
@ENTER-DIRECTORY 380862A05-XX-01D,F-D,1,O-
- Run the mode file:
@MODE (380862:FLOPPY-USER)SM-PATCH-A05:PATC "SM-PATCH-A05:POUT"-
- Check the output file for errors
@RELEASE-DIRECTORY 380862A05-XX-01D-
- Define the standard domain again.
Log in as user:
SYSTEM
@ND-
DEFINE-STANDARD-DOMAIN SIBAS-MANAGER-A05 (SIBR-B)SM-OPERATOR-A05-
EXIT-
- The installation of this product is now completed.
ND-895617.1 EN
Page 6¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.10.15 | 6 of 6 |
| Product name | Product number |
|---|---|
| SIBAS Manager for ND-500/5000 Patch File | 380862A |
5 Modifications¶
5.1 New Functions/Commands¶
None
5.2 Changed Functions/Commands¶
None
5.3 Removed Functions/Commands¶
None
5.4 Other Modifications¶
The SW-Config command CHECKPOINT-INTERVAL = 0 means checkpoint-interval off.
6 Errors Corrected¶
The patch file contains patches from the CSI (Customer-Support-Information) database for SIBAS Manager (ND-211455A).
Patch number: 2, 3, 6, 8, 9
7 Errors Known But Not Corrected¶
None
ND-895617.1 EN