Page 1¶
Product Information¶
| Product name | Product number |
|---|---|
| Test programs for ND-100/110/120 | 210523H |
Description of product¶
The product contains the following test programs for the ND-100/110/120 CPUs, memory systems, and ND-100 type interfaces and peripherals:
| File Name | Type | Containing |
|---|---|---|
| TPE-MON-100-B |
BPUN | Test program monitor |
| CACHE-1X0-A |
TEST | Cache test for ND-1x0 CPUs |
| COLOUR-TERM- |
TEST | NCT / TCTI test program |
| CONFIGURATIO-D |
TEST | Checks HW configuration |
| DISC-TEMA-1 |
TEST | Disk utility and test program |
| DISK-MM-B |
TEST | Disk media maintenance program |
| FLOPPY-STREA-C |
TEST | Floppy and streamer test |
| GRAPHIC-TERM-B |
TEST | Verify TDV 2200S graphic functions |
| HDLC-MEGALIN-D |
TEST | HDLC and megalink test program |
| INSTRUCTION-C |
TEST | Verify ND-1x0 CPUs instruction set |
| LP-TEST-E |
TEST | Line printer test program |
| MAGTAPE-B |
TEST | Cipher / Pertec magtape test |
| MEMORY-D |
TEST | Memory test program |
| NET-ONE-A |
TEST | Net/One test program |
| OCTOBUS-B |
TEST | Octobus test program |
| PAGING-C |
TEST | Memory Management test for ND-1x0 |
| PIOC-ETHER-B |
TEST | Pioc / Ethernet test program |
| POWER-FAIL-A |
TEST | Power fail and restart test |
| PRINTERS-B |
TEST | Printer test for ND printers |
| SCSI-TV-C |
TEST | SCSI Test and Verification |
| SYNC-MODEM-B |
TEST | Sync modem interface test program |
| TERMINAL-ASY-F |
TEST | Terminal interface test program |
| UNIVERS-DMA-C |
TEST | Universal dma / Vicom test program |
NOTE:
Reason(s) for new product or version¶
- New product
- Change/addition
-
- Error correction
-
- Different environment
-
Page 2¶
Product Information¶
| Product name | Product number |
|---|---|
| Test programs for ND-100/110/120 | 210523H |
Table of Contents¶
| Page | |
|---|---|
| Prerequisites | 2 |
| Documentation | 3 |
| Installation procedure | 3 |
| Modifications and errors corrected | 6 |
| Errors known but not corrected | 7 |
| Where to find the different programs | 8 |
1 Prerequisites¶
The following are required in order to use this product.
1.1 Hardware prerequisites¶
The following hardware must be present for this product to be used:
CPU type (any of the following):
- 100 Standard
- 100 CX
- 110 Standard
- 110 CX
- 120 Standard
- 120 CX
Floating format: Any
1.2 Software prerequisites¶
The following software must be installed on the system for this product to be used:
Operating system:
Name
- Stand-alone programs, or
- SINTRAN III VSE/VSX
Page 3¶
Page 3 of 8
+-----------------+------------------------------------+
| | |
| .. .. .. .. | Product Information |
| .. .. .. .. | |
| .. .. .. .. |------------------------------------|
| .. .. .. .. | Product name | Product |
| .. .. .. .. | | number |
| .. .. .. .. | Test programs for | 210523H |
| .. .. .. .. | ND-100/110/120 | |
| | |
+-----------------+------------------------------------+
| Norsk Data |
+-----------------------------------------------------+
2 Documentation¶
Included (distributed free with product)
| Title | Number |
|---|---|
| Test Program Description for ND-100/ND-110 | 830005.3 EN |
| Test Program Description for ND-100/ND-110 - | 899159.1 EN |
| Addendum |
3 Installation procedure¶
3.1 Loading procedure – stand alone¶
The machine must be in STOP. Press MASTER CLEAR and type 1560& on the console.
If autoload is not disabled (see description of FLOPPY-MON-H), TPE-MONITOR will start up and give the prompt:
TPE>
Manual loading:
FLOPPY-MON-H02
*LOAD TPE-MON-100
When TPE-MONITOR is started, use the command LOAD-PROGRAM to load the desired program:
TPE>LOAD-PROGRAM <program name>
or just:
TPE><program name>
The program is loaded if no error messages appear.
To list the programs available on diskette, use the command LIST-FILES:
TPE>LIST-FILES <file-name>
Scanned by Jonny Oddene for Sintran Data © 2024
Page 4¶
.##.
#..#
.#.#
..#.
###.
.#.
#
Product Information¶
| Product name | Product number |
|---|---|
| Test programs for ND-100/110/120 | 210523H |
3.2 Online installation¶
The TPE-MONITOR can execute under SINTRAN in different modes.
Installation on-line:
- Log in under the user where you want to execute the programs.
- Place the floppy diskette in floppy controller 1 unit 0.
-
Type the command:
@ENTER-DIRECTORY 210523H FLOPPY-DISC-1 0 -
Start the TPE-MONITOR with the command:
@LOAD-BINARY {210523H:FLOPPY-USER}TPE-MON-100-B↵
The TPE-MONITOR now starts and you can load the different test programs by using the command LOAD-PROGRAM.
TPE>LOAD-PROGRAM {210523H:FLOPPY-USER}<program name>
Page 5¶
Product Information¶
| Product name | Product number |
|---|---|
| Test programs for ND-100/110/120 | 210523H |
Permanent installation in the system can be done like this:
-
Log in as user SYSTEM.
-
Place the floppy diskette in floppy controller 1 unit 0.
-
Type the command:
@ENTER-DIRECTORY 210523H FLOPPY-DISC-1 0 -
Copy the TPE-MONITOR to the disk by the command COPY-FILE
@COPY-FILE DESTINATION FILE: "TPE-MON-100-B<rev.>:BPUN" SOURCE FILE: (210523H:FLOPPY-USER)TPE-MON-100-B<rev.>:BPUN -
Dump the TPE-MONITOR by the command DUMP-REENTRANT
@DUMP-REENTRANT NAME: TPE-MON-100-B<rev.> START ADDRESS: 0 RESTART ADDRESS: 20 FILE-NAME:TPE-MON-100-B<rev.>:BPUN
The TPE-MONITOR is now installed. You can start it by typing:
@TPE-MON-100
The test programs can now be started by using the LOAD-PROGRAM command in the TPE-MONITOR.
@TPE-MON-100 <program name>
Page 6¶
Product Information¶
| Product name | Product number |
|---|---|
| Test programs for ND-100/110/120 | 210523H |
4 Modifications and errors corrected¶
4.1 TPE-MON-100-B¶
Errors corrected:
- After power down - power up, the software clock did not start in several minutes.
- Error in the UPDAT command's leap year calculation.
- Reading of panel clock sometimes failed because of insufficient testing of the panel-processor status bits.
4.2 DISK-MM-B¶
Errors corrected:
It is now possible to run the program with 32MB memory available for the ND-1X0 (including MPM5 memory).
4.3 CONFIGURATIO-D¶
Modifications:
Implemented Floppy/SCSI card 3205.
4.4 FLOPPY-STREA-C¶
Modifications:
- Implemented Floppy/SCSI card 3205.
- The filemark test is removed from the program (the test does not work properly because of an interface-controller error).
Page 7¶
Product Information¶
| Product name | Product number |
|---|---|
| Test programs for ND-100/110/120 | 210523H |
4.5 POWER-FAIL-A¶
Errors corrected:
- Because of the errors in TPE B00 listed above, clock inconsistency was sometimes detected by the power fail test program. This resulted in a fatal error message (error code 100000B) and program abortion.
- In this revision, clock inconsistency will not result in program abortion.
4.6 SCSI-TV-C¶
Errors corrected:
It is now possible to run the program with 32MB memory available for the ND-1X0 (including MPM5 memory).
Modifications:
-
New products supported by this version:
Product Model Description NCDCDC 94171-9 WREN IV, 5 1/4" fixed disk Exabyte 8200 Gigatape system HP 88780 Magtape
- Runs under SINTRAN (ver. L) / user SYSTEM.
- Media tests for optical disk are implemented.
5 Errors known but not corrected¶
See the manual Test Program Description for ND-100/ND-110 - Addendum (ND-899159.1 EN) for details.
Page 8¶
ND Product Information¶
| Product name | Product number |
|---|---|
| Test programs for ND-100/110/120 | 210523H |
6 Where to find the different programs¶
| Programs | Diskette |
|---|---|
| CACHE-1XO-A |
01D/02S |
| COLOUR-TERM-A |
01D/04S |
| CONFIGURATIO-D |
01D/01S |
| DISC-TEMA-1 |
01D/01S |
| DISK-MM-B |
02D/05S |
| FLOPPY-STREA-C |
01D/05S |
| GRAPHIC-TERM-B |
01D/04S |
| HDLC-MEGALIN-D |
01D/03S |
| INSTRUCTION-C |
01D/02S |
| LP-TEST-E |
01D/04S |
| MAGTAPE-B |
01D/05S |
| MEMORY-D |
01D/01S |
| NET-ONE-A |
01D/02S |
| OCTOBUS-B |
01D/03S |
| PAGING-C |
01D/02S |
| PIOC-ETHER-B |
01D/03S |
| POWER-FAIL-A |
01D/01S |
| PRINTERS-B |
01D/04S |
| SCSI-TV-C |
02D/--- |
| SYNC-MODEM-B |
01D/03S |
| TERMINAL-ASY-F |
01D/01S |
| UNIVERS-DMA-C |
01D/02S |
Note:
SCSI-TV is only available on double sided diskette.