Page 1¶
Product Information¶
| Product name | Product number |
|---|---|
| Y for ND-500/5000 | 300001A |
Description of Product¶
Y is a powerful screen utility program which will clear your screen and move the cursor to its HOME position.
Reason(s) for New Product or Version¶
New product.
Table of Contents¶
| No | Content | Page |
|---|---|---|
| 1 | List of files | 2 |
| 2 | Prerequisites | 3 |
| 3 | Dependencies | 5 |
| 4 | Documentation | 5 |
| 5 | Installation procedure | 6 |
| 6 | Information | 7 |
| 7 | Limitations | 7 |
| 8 | Modifications | 7 |
| 9 | Errors corrected | 7 |
| 10 | Errors known but not corrected | 7 |
Page 2¶
Norsk Data¶
Product Information¶
| Product name | Product number |
| Y for ND-500/5000 | 300001A |
1 List of files¶
Directory name: 300001A00-XX-01D
User name: FLOPPY-USER
| No. | File name | Type | T | Public | Friend | Own | Pages | Bytes |
|---|---|---|---|---|---|---|---|---|
| 0 | Y-XX-A00 | DOM | I | R | R | RWACD | 5 | 8192 |
1 file using 5 pages. 610 pages reserved out of 616.
Norsk Data A/S - Software Library
Scanned by Jonny Oddene for Sintran Data © 2011
Page 3¶
Norsk Data Product Information¶
| Product name | Product number |
|---|---|
| Y for ND-500/5000 | 300001A |
2 Prerequisites¶
The following are required in order to use this product.
2.1 Hardware prerequisites¶
The following hardware must be present in the computer for this product to be used:
| CPU type | Std/CE/CX | Floating format |
|---|---|---|
| ND-500 | All | All |
| or ND-5000 | All | All |
Other hardware: Number/Print/ECO
None
2.2 Software prerequisites¶
The following software must be installed on the computer for this product to be used:
| Operating system | Version/Revision |
|---|---|
| SINTRAN III VSX/500 | >= K workmode 500 |
Other software: Number/Version/Rev.
None
Norsk Data A/S - Software Library
Scanned by Jonny Oddene for Sintran Data © 2011
Page 4¶
Norsk Data¶
Product Information¶
| Product name | Product number |
|---|---|
| Y for ND-500/5000 | 300001A |
2.3 Other prerequisites¶
The following are necessary for this product to be used:
Minimum permanent mass storage required¶
| SINTRAN user | Space (pages) | Number of files |
|---|---|---|
| DOMAIN-USER | 5 | 1 |
Temporary mass storage required for installation¶
| SINTRAN user | Space (pages) | Number of files |
|---|---|---|
| None |
| Minimum | Maximum | |
|---|---|---|
| Number of segments (ND-100) | 0 | 0 |
| Number of RT descriptions | 0 | 0 |
Space required on segment files: 0 pages
Norsk Data A/S - Software Library
Scanned by Jonny Oddene for Sintran Data © 2011
Page 5¶
Product Information¶
| Product name | Product number |
|---|---|
| Y for ND-500/5000 | 300001A |
3 Dependencies¶
In addition to the above listed hardware and/or software prerequisites, the following dependencies exist between this and other products. The hardware and software listed here may, for example, be necessary to use the product's full functionality.
3.1 Hardware dependencies¶
| Product name | Number/Print/ECO |
|---|---|
| None |
3.2 Software dependencies¶
| Product name | Number/Version/Rev. |
|---|---|
| None |
3.3 Other dependencies¶
None
4 Documentation¶
One copy included (distributed free with product).
| Title | Number |
|---|---|
| Y - Reference Manual | 880001.02 EN |
Norsk Data A/S - Software Library
Scanned by Jonny Oddene for Sintran Data © 2011
Page 6¶
Product Information¶
| Product name | Product number |
|---|---|
| Y for ND-500/5000 | 300001A |
5 Installation procedure¶
5.1 Automatic installation¶
None
5.2 Non-automatic installation¶
- Check prerequisites listed in chapter 2.
- Log in as user DOMAIN-USER.
- Insert the floppy 300001A00-XX-01D into a vacant floppy unit.
- Enter the directory and do as follows:
@COPY-FILE
DESTINATION FILE: "Y-XX-A00:DOM"
SOURCE FILE: (300001A00-XX-01D:FLOPPY-USER)Y-XX-A00:DOM
- Release the directory and remove the floppy.
- Log in as user SYSTEM and do as follows:
@ND-500-MONITOR
N500: DEFINE-STANDARD-DOMAIN
Standard domain name: Y-XX-A00
Domain name: (DOMAIN-USER)Y-XX-A00
N500: EXIT
5.3 Updates to the system operation files¶
- Remember to update the (SYSTEM)ND500-HENT-MODE:MODE file (or corresponding) with the following commands:
@ND-500-MONITOR
DELETE-STANDARD-DOMAIN Y-XX-A00
DEFINE-STANDARD-DOMAIN Y-XX-A00 (DOMAIN-USER)Y-XX-A00
EXIT
••• Norsk Data A/S - Software Library •••
Scanned by Jonny Oddene for Sintran Data © 2011
Page 7¶
Norsk Data¶
Product Information
| Product name | Product number |
|---|---|
| Y for ND-500/5000 | 300001A |
6 Information¶
Y will clear the screen on the following terminals (and all terminals that use CTRL-Y as "clear screen").
- TDV-21xx
- TDV-22xx
- TDV-12xx (in 2115 mode only)
7 Limitations¶
Y does not work on TDV-1200 terminals if the terminal is in Native mode.
8 Modifications¶
None
9 Errors corrected¶
None
10 Errors known but not corrected¶
None
Norsk Data A/S - Software Library
Scanned by Jonny Oddene for Sintran Data © 2011