Skip to content

Page 1

Product Information

Product name Product number
Y for ND-500/5000 300001A

Description of Product

Y is a powerful screen utility program which will clear your screen and move the cursor to its HOME position.

Reason(s) for New Product or Version

New product.

Table of Contents

No Content Page
1 List of files 2
2 Prerequisites 3
3 Dependencies 5
4 Documentation 5
5 Installation procedure 6
6 Information 7
7 Limitations 7
8 Modifications 7
9 Errors corrected 7
10 Errors known but not corrected 7

Page 2

Norsk Data

Product Information

Product name Product number
Y for ND-500/5000 300001A

1 List of files

Directory name: 300001A00-XX-01D
User name: FLOPPY-USER

No. File name Type T Public Friend Own Pages Bytes
0 Y-XX-A00 DOM I R R RWACD 5 8192

1 file using 5 pages. 610 pages reserved out of 616.


Norsk Data A/S - Software Library

Scanned by Jonny Oddene for Sintran Data © 2011


Page 3

Norsk Data Product Information

Product name Product number
Y for ND-500/5000 300001A

2 Prerequisites

The following are required in order to use this product.

2.1 Hardware prerequisites

The following hardware must be present in the computer for this product to be used:

CPU type Std/CE/CX Floating format
ND-500 All All
or ND-5000 All All

Other hardware: Number/Print/ECO

None

2.2 Software prerequisites

The following software must be installed on the computer for this product to be used:

Operating system Version/Revision
SINTRAN III VSX/500 >= K workmode 500

Other software: Number/Version/Rev.

None


Norsk Data A/S - Software Library

Scanned by Jonny Oddene for Sintran Data © 2011


Page 4

Norsk Data

Product Information

Product name Product number
Y for ND-500/5000 300001A

2.3 Other prerequisites

The following are necessary for this product to be used:

Minimum permanent mass storage required

SINTRAN user Space (pages) Number of files
DOMAIN-USER 5 1

Temporary mass storage required for installation

SINTRAN user Space (pages) Number of files
None
Minimum Maximum
Number of segments (ND-100) 0 0
Number of RT descriptions 0 0

Space required on segment files: 0 pages

Norsk Data A/S - Software Library

Scanned by Jonny Oddene for Sintran Data © 2011


Page 5

Product Information

Product name Product number
Y for ND-500/5000 300001A

3 Dependencies

In addition to the above listed hardware and/or software prerequisites, the following dependencies exist between this and other products. The hardware and software listed here may, for example, be necessary to use the product's full functionality.

3.1 Hardware dependencies

Product name Number/Print/ECO
None

3.2 Software dependencies

Product name Number/Version/Rev.
None

3.3 Other dependencies

None

4 Documentation

One copy included (distributed free with product).

Title Number
Y - Reference Manual 880001.02 EN

Norsk Data A/S - Software Library

Scanned by Jonny Oddene for Sintran Data © 2011


Page 6

Product Information

Product name Product number
Y for ND-500/5000 300001A

5 Installation procedure

5.1 Automatic installation

None

5.2 Non-automatic installation

  • Check prerequisites listed in chapter 2.
  • Log in as user DOMAIN-USER.
  • Insert the floppy 300001A00-XX-01D into a vacant floppy unit.
  • Enter the directory and do as follows:
@COPY-FILE
DESTINATION FILE: "Y-XX-A00:DOM"
SOURCE FILE: (300001A00-XX-01D:FLOPPY-USER)Y-XX-A00:DOM
  • Release the directory and remove the floppy.
  • Log in as user SYSTEM and do as follows:
@ND-500-MONITOR
N500: DEFINE-STANDARD-DOMAIN
Standard domain name: Y-XX-A00
Domain name: (DOMAIN-USER)Y-XX-A00
N500: EXIT

5.3 Updates to the system operation files

  • Remember to update the (SYSTEM)ND500-HENT-MODE:MODE file (or corresponding) with the following commands:
@ND-500-MONITOR
DELETE-STANDARD-DOMAIN Y-XX-A00
DEFINE-STANDARD-DOMAIN Y-XX-A00 (DOMAIN-USER)Y-XX-A00
EXIT

••• Norsk Data A/S - Software Library •••

Scanned by Jonny Oddene for Sintran Data © 2011


Page 7

Norsk Data

Product Information

Product name Product number
Y for ND-500/5000 300001A

6 Information

Y will clear the screen on the following terminals (and all terminals that use CTRL-Y as "clear screen").

  • TDV-21xx
  • TDV-22xx
  • TDV-12xx (in 2115 mode only)

7 Limitations

Y does not work on TDV-1200 terminals if the terminal is in Native mode.

8 Modifications

None

9 Errors corrected

None

10 Errors known but not corrected

None


Norsk Data A/S - Software Library

Scanned by Jonny Oddene for Sintran Data © 2011