Page 1¶
Product Information¶
| Product name | Product number |
|---|---|
| SIBAS/R Backend | 220004B |
Description of Product¶
The product consists of a SIBAS/R Backend Software Licence Key and a description of how to activate the Backend-module for the general purpose database management system SIBAS/R over COSMOS and/or TCP/IP communication.
See ch. "Dependencies" for a list of other parts of SIBAS/R.
Reason(s) for New Release¶
- New Software Licence Key system in SIBAS/R B
Table of Contents¶
| Page | |
|---|---|
| Prerequisites | 2 |
| Dependencies | 5 |
| Documentation | 6 |
| Installation procedure | 7 |
| Modifications (B05) | 10 |
| Errors corrected | 10 |
| Errors known but not corrected | 10 |
ND-895628.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 2¶
Product Information¶
Date: 90.10.12
Norsk Data
Page: 2 of 10
Product Name¶
SIBAS/R Backend
Product Number¶
220004B
1 Prerequisites¶
The following is required in order to use this product.
1.1 Hardware Prerequisites¶
The following hardware must be present for this product to be used:
CPU type (any of the following): - 500 - 5000
Floating format: Any
Other hardware:
| Product Name | Product Number |
|---|---|
| None | None |
1.2 Software Prerequisites¶
The following software must be available on the system before the product is installed:
Operating System:
| Name | Version/Revision |
|---|---|
| SINTRAN-III >= L Workmode 7 | >=4000 |
| Micro-code for ND-5000 | >=MICRO-xx-B30 |
ND-895628.1 EN
Page 3¶
Product Information¶
| Date | Page |
|---|---|
| 90.10.12 | 3 of 10 |
| Product name | Product number |
|---|---|
| SIBAS/R Backend | 220004B |
Other Software¶
| Product name | Product number |
|---|---|
| - On the database machine: | |
| SIBAS/R version B | ND-220001 B / |
| ND-220002 B | |
| SOFIICE, Software Key Installation | ND-211846 A |
| Program | |
| - On ND-100/500/5000 application | |
| machines: | |
| SIBAS/R Client Package | ND-220003 B |
| - On OWS's: | |
| SIBAS/R library for OWS version A | ND-230030 A |
| - On Uniline XO: | |
| SIBAS/R library for Uniline XO | ND-230164 B |
1.3 Other Prerequisites¶
Minimum Permanent Mass Storage:
| User | Space (pages) | Number of files |
|---|---|---|
| None | 0 | 0 |
Minimum
| Number of segments (ND-100) | 1 |
| Number of RT descriptions | 1 |
Space required on segment files: 128 pages
Requirements regarding internal devices:
None
Requirements regarding batch processors:
None
ND-895628.1 EN
Page 4¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.10.12 | 4 of 10 |
| Product name | Product number |
|---|---|
| SIBAS/R Backend | 220004B |
Requirements regarding Nucleus resources:¶
- The Manager Module needs:
- Message buffer space for system processes in pages: 4
- Number of descriptors for system processes: 13
- Each Controller Module needs:
- Message buffer space for system processes in pages: 125
- Number of descriptors for system processes: 275
Requirements regarding XMSG resources:¶
- The manager module needs:
- Number of task descriptors: 1
- Number of ports: 24
- Number of message elements: 24
- Buffer space: 2 kbyte * 24
ND-895628.1 EN
Page 5¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.10.12 | 5 of 10 |
| Product name | Product number |
|---|---|
| SIBAS/R Backend | 220004B |
2 Dependencies¶
In addition, the following dependencies exist between this and other products. The hardware and software listed here, may for example be necessary to make full use of the product.
2.1 Hardware Dependencies¶
| Product name | Product number |
|---|---|
| None | None |
Nature of dependency
None
2.2 Software Dependencies¶
The following products are other parts of SIBAS/R system:
| Product name | Product number |
|---|---|
| SIBAS/R for ND-500/5000 | ND-220001B |
| SIBAS/R Client Package | ND-220003B |
| -Libraries for ND-100/500/5000 | |
| for access to the database from | |
| a front end machine and | |
| Service programs. | |
| SIBAS/R Runtime | ND-220002A |
| -Runtime version for ND-500/5000 | |
| (development not allowed). | |
| SIBAS/R Library for Uniline XO | ND-230164B |
| -For access to the database from | |
| a Uniline XO | |
| SIBAS/R Library for OWS | ND-230030A |
| -For access to the database from | |
| PC applications | |
| SIBAS/R Softkey for Development Access | ND-220005B |
| -Software licence key for | |
| development access. | |
| SIBAS/R SQL-Library for ND-500/5000 | ND-211574B |
| SIBAS/R SQL-Interactive for ND-500/5000 | ND-211575B |
Nature of dependency
Other parts of SIBAS/R
ND-895628.1 EN
[Scanned by Jonny Oddene for Sintran Data © 2011]
Page 6¶
Product Information¶
| Date | 90.10.12 |
|---|---|
| Norsk Data | Page 6 of 10 |
| Product name | Product number |
|---|---|
| SIBAS/R Backend | 220004B |
2.3 Other Dependencies¶
You should also be aware of the following dependencies:
| Product name | Product number |
|---|---|
| None | None |
Nature of dependency
None
3 Documentation¶
Included with the product
| Title | Number |
|---|---|
| None |
Optional (must be purchased)
| Title | Number |
|---|---|
| OpenLAN Network Supervisor Guide | ND-830107.3 |
| Dialogue - Operation | ND-830072.2 |
ND-895628.1 EN
Page 7¶
Product Information¶
| Date | 90.10.12 |
|---|---|
| Norsk Data | Page 7 of 10 |
Product Name: SIBAS/R Backend
| Product Number |
|---|
| 220004B |
4 Installation Procedure¶
- All applications using SIBAS must be stopped. All SIBAS processes of version SIBAS-II-F, SIBAS/R-A, and SIBAS/R-B must be PASSIVE. Use SIBAS-SERVICE/STATUS/ALL DATABASES to check if there are active processes.
4.1 Automatic Installation¶
- Log in as user SYSTEM
- Use the utility program SOFTICE (ND-211846A) to install the Backend Software Licence Key on the database machine. The Software Licence Key is delivered on a Software Licence Key Certificate following this product.
@ND SOFTICE
STORE-SOFTWARE-KEY 220004 <software key> <SIBAS/R Backend>
EXIT
4.2 Completing the Installation¶
When the Software Licence Key has been installed:
-
How to run SIBAS Backend:
It may be necessary to increase the following parameters for the XMSG, (by using XMSG-IN), on the application machine:
X5PRT (number of ports) : one for each application X4MES (number of message elements) : one for each application X4BPG (buffer space in pages) : max. one page per active application.The SIBAS Backend name of the database machine should be defined in XMSG, for both the application machine and the database machine. This is done by the use of the following commands:
@XMSG-COMMAND- DEFINE-REMOTE-NAME,-*SIBn,<Database-machine-system-number>- EXIT-where "n" should be an integer value between 1 and 326. This means that it is possible to communicate with up to 326 database machines from one application machine.
<Database-machine-system-number>is the CPU-number of the database machine.
Read the rest of this section if you are going to use your SIBAS/R Backend over TCP/IP, in addition to COSMOS.
ND-895628.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 8¶
Product Information¶
| Date | Page |
|---|---|
| 90.10.12 | 8 of 10 |
| Product name | Product number |
|---|---|
| SIBAS/R Backend | 220004B |
- Fetch the AIP-HOSTS:SYMB file in your OpenLAN network used for manual updating. Update the file with information concerning the computer where the SIBAS Backend has been installed, as follows:
-
Isolate all records concerning the Ethernet III controllers where the TCP/IP Basic Module/III is installed. (If you don't know the addresses of these controllers, you can find them by reading the file AIP-CONFIG:SYMB which contains information on all the local Ethernet-controllers running TCP/IP. All controllers with TCP-device number >= 4 are running the TCP/IP Basic Module/III)
- Remove the service SIB=551 if defined for any of the controllers.
- Define the service SIBRCOM-561 (in the comment-field) for ALL the controllers.
-
Isolate all records concerning the Ethernet III controller where the TCP/IP Basic Module/III is installed as TCP-device number 4. (If you don't know the address of this controller, you can find it by reading the file AIP-CONFIG:SYMB which contains information on all the local Ethernet-controllers running TCP/IP).
- Define the SIBAS Backend name ('**sibN') of the computer as Alias name for the controller. See the DIALOGUE Operations (830072.2 EN for information on the name).
- Define the service SIB=560 (in the comment-field).
Example:
130.067.006.009 dbmachine *sibl # SIB=560 SIBRCOM=561
Be sure to distribute the updated file to all computers concerned.
See the OpenLAN Network Supervisor Guide (830107.3 EN) for more information.
Scanned by Jonny Oddene for Sintran Data © 2011
ND-895628.1 EN
Page 9¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.10.12 | Product Name | 9 of 10 |
| Product Name | Product Number |
|---|---|
| SIBAS/R Backend | 220004B |
-
Fetch the AIP-SERVICES:SYMB file in your OpenLAN network used for manual updating, and update the file as follows:
- Include the service SIB-560/TCP if not already defined.
- Include the service SIBRCOM-561/TCP if not already defined.
Be sure to distribute the updated file to all computers concerned.
See the OpenLAN Network Supervisor Guide for more information.
-
Update the mode file that is run after a cold start (usually called HENT-MODE:MODE) by including the following line:
@MODE (SIBR-B)SIBCOM-LOAD-B:MODE,,,
-
Update the mode file that is run after a warm start (usually called LOAD-MODE:MODE) by including the following line after starting the TCP/IP Basic Module/III:
@MODE (SIBR-B)SIBCOM-START-B:MODE,,,
4.2 Non-Automatic Installation¶
None
ND-895628.1 EN
[Scanned by Jonny Oddene for Sintran Data © 2011]
Page 10¶
Product Information¶
| Date | 90.10.12 |
|---|---|
| Company | Norsk Data |
| Page | 10 of 10 |
| Product name | SIBAS/R Backend |
| Product number | 220004B |
5 Modifications¶
5.1 New Functions/Commands¶
None
5.2 Changed Functions/Commands¶
None
5.3 Removed Functions/Commands¶
None
5.4 Other Modifications¶
New Software Licence Key system implemented in SIBAS/R B.
6 Errors Corrected¶
None
7 Errors Known But Not Corrected¶
None
ND-895628.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011