Page 1

Product Information

Product name Product number
Basic System Package for ND-5000 Systems 380799A

Description of Product

Basic System Package for ND EServer is a part of the Basic System Package for ND EServer (ND-211731), which is a prepackaged system for the ND EServer with menu-oriented operation routines for easy operating.

Reason(s) for New Product or Version

The reason for this product is to give Supervisors and other persons responsible for system operation an easy and quick way to upgrade the basic software on all ND EServer models. This product is designed to be used when a new version/revision of the basic software on the ND EServer is required. All the software on this product is pre-packed and may easily be installed. This product will be installed and prepared by ND on all deliveries of ND EServer models.

Table of Contents

Page
1 Prerequisites 2
2 Dependencies 2
3 Documentation 2
4 Packing List 3
5 Read this first. 3
6 Manual installation procedure. 3
7 Errors corrected 8
8 Errors known but not corrected 8
9 Limitations 9
10 Products included 10
11 General Information 11

ND-895560.1 EN

Scanned by Jonny Oddene for Sintran Data © 2011


Page 2

Product Information

Date: 90.06.18
Norsk Data
Page: 2 of 15

Product name Product number
Basic System Package for ND-5000 Systems 380799A

1 Prerequisites

The following things are required in order to use this product.

  • Prerequisite for all ND EServer models:
    • One of the following platform kits:
      • ND-110966, ND-110967, ND-111194, ND-111195, ND-111196.
    • Disk Restore (ND-211187 B)
    • A scratch Streamer Cassette.

2 Dependencies

The system disk must be divided into four subunits (DISC-4-SCSI-1), each with the directory size 77 Mbyte.

Only internal updates are allowed on PACK-BASIC on the ND EServer.

3 Documentation

There is one manual for the ND EServer describing different operation parts supported by a menu system, and how to maintain these operation parts. Necessary documentation for the product elements is included in the total delivery of the ND EServer (ND-870027 Basic Documentation Package for ND EServer).

The most important operation documentation:

Guide Code
COSMOS User Guide ND-860163.4
SPRINT User Guide ND-860252.2 EN
ND EServer System Administrator Guide ND-830147.1 EN
Backup Manager User Guide ND-860276.2 EN
COSMOS Operator Guide ND-830025.2 EN
OEM User Guide ND-830101.1 EN
DOMINO SCSI Operator guide ND-814009.1 EN
ND-LINKER User Guide & Reference ND-860289.2 EN
COSMOS Operator Card ND-899002.2 EN
COSMOS User Card ND-899001.2 EN

ND-895560.1 EN

Scanned by Jonny Oddene for Sintran Data © 2011


Page 3

Product Information

Date Norsk Data Page
90.06.18 3 of 15
Product name Product number
Basic System Package for ND-5000 Systems 380799A

4 Packing List

ND-211731 A - 1 Streamer Cassette with Basic SW Package I for ND EServer.

5 Read This First

Rules concerning Es platform systems.

The Es platform consists of four directories:

PACK-BASIC      -----> DISC-4-SCSI-1,0,0
PACK-MAIN       -----> DISC-4-SCSI-1,0,1
PACK-EXTENSION  -----> DISC-4-SCSI-1,0,2
PACK-APPLICATION -----> DISC-4-SCSI-1,0,3

a) PACK-BASIC contains system files and has to remain
as it is when delivered from NORSK DATA A.S.
Some few exceptions exist.

b) PACK-MAIN contains configuration files for the
system, USER-ENVIRONMENT and customer-defined
users. Available space is free for the customer to use.

c) PACK-EXTENSION contains your additional ND applications
such as NOTIS, SIBAS, TCP-IP and so on.

d) PACK-APPLICATION is reserved for the different
business units belonging to NORSK DATA and their
application packages.

NO-895560.1 EN

Scanned by Jonny Oddene for Sintran Data © 2011


Page 4

Product Information

Date Norsk Data Page 4 of 15
Product name Product number
Basic System Package for ND-5000 Systems 380799A

6 Manual Installation Procedure

This procedure should be followed when a new version of the Basic System Package is to be installed.

+--------------------------------------------------+
| CAUTION!                                         |
|                                                  |
| All software located on PACK-BASIC-A will be     |
| destroyed and a new version of PACK-BASIC-A will |
| be restored from the streamer. On user SYSTEM    |
| there may be files belonging to other products   |
| than those listed in chapter 10 (libraries, init |
| files etc.). Backup of these files must be taken |
| before the disk is restored.                     |
+--------------------------------------------------+
  1. Preparations before stopping the ND EServer:

    a) Check that the file (MODE-FILES)DEF-PERIPHERALS:MODE corresponds to your system before you take the system down.

    b) Save user files to a scratch streamer cassette using the Backup Manager:

    - Insert a scratch streamer cassette into the streamer drive. - Log in as user SYSTEM and start the BACKUP-MANAGER from the ND EServer System Administrator menu option 3.0 (backup) or from SINTRAN by doing the command @BM-OPERATOR-. - Use the backup set BACKUP-FILES to save not standard platform files to streamer. All files and users NOT listed in the file (PROG-FILES)EXCLUDE-FILES:SYMB will be copied to the streamer cassette.

    When the new Basic System Package is installed, these files can be copied back to user SYSTEM on PACK-BASIC-A (ref. point 1h.).


Page 5

Product Information

Date Norsk Data Page
90.06.18 5 of 15
Product name Product number
Basic System Package for ND-5000 Systems 380799A

c) Passwords

Write down the following passwords:

  • SYSTEM (sintran password)
  • MULTI-OE (user-environment password)
  • SIBAS-MANAGER (user-environment password)

d) Perform a controlled shutdown of the ND EServer:

Log in to user SYSTEM and execute the command:

@MODE·(MODE-FILES)ES-SHUTDOWN:MODE

All configuration dependent system-files located on PACK-BASIC-A will be copied to user CONFIG-FILES on PACK-MAIN-SW.

Press STOP and MACL (Master Clear) buttons from the operator panel!

ND-895560.1 EN


Page 6

Product Information

Date Norsk Data Page 6 of 15
Product name Product number
Basic System Package for ND-5000 Systems 380799A

e) Install the new platform:

Insert the ND-211731A streamer cassette in the streamer drive.
Use Disk Restore version B to copy the streamer cassette to the system disk (Device: DISC-4-SCSI-1 unit:0 subunit:0).
Ref. PI sheet for Disk Restore (ND-211187 B).

Di-Re: RESTORE-DISK

From (Directory/Volume VOLUME
Source device name STREAMER-1
Source device unit 0
Retension(Yes/No) YES
Compare (Yes/No) YES
Destination device name DISC-4-SCSI-1
Destination device unit 0
Destination device subunit 0

Retension

Mounted volume is: PACK-BASIC-A
on device: STREAMER-1,0

Give command (Continue/Retry/Cancel) : CONTINUE

Searching

-------------- Image found -------------------
Volume   : PACK-BASIC-A
Reel     : 1

Index    : 1
Computer :
Directory: PACK-BASIC-A
Device   : DISC-4-SCSI-1,0,0
Pages    : 37685
Backed up: 90-06-10
Control  : RdFc
----------------------------------------------

Confirm start of restore (Start/Next-Image/Cancel) : START

Directory: PACK-BASIC-A
detected on the device: DISC-4-SCSI-1,0,0

Give command (Retry/Overwrite/Cancel): OVERWRITE

Copying (DMA)
Rewinding
Comparing

This takes about 22 minutes with compare.

ND-895560.1 EN

[Scanned by Jonny Oddene for Sintran Data © 2011]


Page 7

Product Information

Date Norsk Data Page 7 of 15
Product name Basic System Package for ND-5000 Systems Product number
380799A

When this operation is finished continue with next point.

f) Initialising the new platform:

Press MCL (Master Clear) and the LOAD buttons on the Operator panel.

Then the following text will appear on the terminal:

------------------------------------------------------
! Please continue with next point in the installation !
! procedure in the PI sheet.                         !
------------------------------------------------------
  • Customize the new platform:

g) Platform preparations

Start the installation program
@PLATFORM-INST~
and answer the questions according to your software and hardware on the system.

********************************************************
The installation program will now prepare the system according 
to your specifications.
********************************************************

h) Reinstall the backup of the files backed up with the RESTORE-FILES job in BACKUP-MANAGER.

@BM-OPERATOR~

Files saved in point (1b) will be restored on the new PACK-BASIC-A

i) Do a COLD-START
@COLD-START~

The system is now running through a complete COLD-START and WARM-START.
When the system is restarted the following text is displayed on the console printer and on the console:

>> The ND EServer is available

ND-895560.1 EN


Page 8

Product Information

Date Norsk Data Page
90.06.18 8 of 15
Product name Product number
Basic System Package for ND-5000 Systems 380799A

The installation of the basic platform is now complete and ready to operate with a new version of the basic software.


CAUTION!

Remember to take a complete backup of the System disk PACK-BASIC-A, PACK-MAIN-SW, PACK-EXTENSION and PACK-APPLICATION (PACK-APPLICATION is optional). This is for security reasons in case of disk problems later on.


7 Errors Corrected

All reported errors have been corrected except those listed in section 9.

8 Errors Known But Not Corrected

  • SPRINT Sintran spooling system (211056A05)

    • If on startup of Sprint, device numbers 1032-1039 (and maybe others) are being used, Sprint will not be able to stop the SPRT programs which have reserved these device numbers. Consequently, Sprint will not be able to use the associated printers.
  • BACKUP Manager (211226B04):

    • RESTART-USER in the menu is not fully corrected. It is not possible to do this against a remote server.
    • Problems with treating EOF-status as OK after 'space-EOF' function. This is a problem for non-SCSI mag-tape drives when listing volumes on more tapes.

ND-895560.1 EN


Page 9

Product Information

Date Norsk Data Page 9 of 15
Product Name Basic System Package for ND-5000 Systems Product Number
380799A

9 Limitations

  • BACKUP Manager (211226 B04):

    • Indexed files larger than 65000 pages cannot be copied by Backup Manager. (Contiguous files can be copied when logged in as user SYSTEM)
    • When performing image copying in batch mode (for example, via BM-scheduler) you cannot copy the directory where the input and device output batch files for this job are located. (Normally the directory where user area SYSTEM and ND-OPERATIONS is located).
    • You cannot copy TO a DOMINO/SCSI tape-device from a remote computer.
    • Image backup from N100 disks to tape/GTS devices connected to DSS is not possible.

ND-895560.1 EN

Scanned by Jonny Oddene for Sintran Data © 2011


Page 10

Product Information

Date Norsk Data Page 10 of 15

Product name

Basic System Package for ND-5000 Systems

Product number

380799A

10 Products Included

NDno/VERSION SOFTWARE MODULE SINTRAN USER
250304 L07 SINTRAN III/VSX-500 Standard system A SYSTEM
250360 L0D SINTRAN III/VSX Patch File 106000 SYSTEM
211024 E01 SINTRAN III Configuration program SYSTEM
210913 A00 SINTRAN III Monitor Call Package SYSTEM
211846 A01 SOFTWARE-KEYS SYSTEM
211305 B02 ND-500(0) System Package for SINTRAN III/VSX L
J05 ND-500/5000 Background Monitor PROG-FILES
K04 ND-500/5000 Swapper SYSTEM
C01 ND-500/5000 Place Library SYSTEM
210534 B00 JEC SYSTEM
210721 C01 BRF-Linker PROG-FILES
210375 C00 TELEFIX Files for User Sites PROG-FILES
210337 I05 BACKUP-SYSTEM PROG-FILES
210455 G05 VTM Tables SYSTEM
210319 H02 ND-500 Linkage-Loader BASIC-DOMAIN
210511 D02 ND-500 Exception Library SYSTEM
210080 J00 PED Eng for ND-100 SYSTEM
210532 K00 PED Eng for ND-500 BASIC-DOMAIN
211224 B01 ND Linker for ND-500/5000 BASIC-DOMAIN
211229 A03 Convert-Domain BASIC-DOMAIN
211322 C03 DOMINO Maintenance Kit DOMINO-UTILITY
211321 C03 NUCLEUS Maintenance Kit DOMINO-UTILITY
211479 A08 DSS Basic System SCSI-DOMINO
211480 A08 DSS Libraries DSS-LIBRARIES
211481 A06 DSS Test programs DOMINO-UTILITY
210335 H00 Symbolic Debugger for ND-500/5000 SYSTEM
210336 F01 Symbolic Debugger for ND-110 SYSTEM
211226 B04 Backup Manager BACKUP-MANAGER
210374 F03 COSMOS Basic module COSMOS-BASIC
210580 B03 COSMOS Ethernet option COSMOS-BASIC
211075 C03 File Manager OE-USER
211073 A04 File System Verification OE-USER
211070 A01 User Area Manager OE-USER
211078 A01 Multi-Machine Operator Environment OE-USER
211074 B01 Performance Monitor for ND-100/500(0) OE-USER
211056 A05 SPRINT Spooling System SPRINT-USER

ND-895560.1 EN

[Scanned by Jonny Oddene for Sintran Data © 2011]


Page 11

Product Information

Date Norsk Data Page 11 of 15
90.06.18 Product Information
Product name Product number
Basic System Package for ND-5000 Systems 380799A

11 General Information

  • DSS Basic System (211479 A08):

    • Device parameters should be set with DP-SERVICE for some devices.

    Command: CHANGE-PARAMETERS

    These are:

    CDC disks: Device settle time = 10 sec
               Device power up time = 90 sec
    GTS, STC tapes: No synchronous transfer
    GTS tapes: No. of retries on aborted command = 0
    GTS tapes: Abort command allowed = NO
    

    Remember also when defining the device GTS that the device code = 1.

  • SINTRAN III patches.

    When it is necessary to install SINTRAN from floppies.

    In addition to the patch file 106000 the file (SYSTEM)SINTRAN-PATCHES:MODE has to be run as a mode job after the standard patch file. This file includes additional patches for SINTRAN that is NOT included in the patchfile 106000.

    When a new SINTRAN with patches is installed do the following:

    @COLD-START
    

    Log in and enter the main directory by typing:

    @ENTER-DIRECTORY,,DISC-4-SCSI-1,0,0
    

    Log out and log in as user SYSTEM:

    @SINTRAN-SERVICE
    @SET-COLDSTART-MODE-FILE PACK-BASIC-A,DISC-4-SCSI-1,0,0
    @HENT-MODE:MODE
    @HENT-OUTPUT:LIST
    @EXIT
    @S3-CONFIG GENERATE
    @COLD-START
    

ND-895560.1 EN

[Scanned by Jonny Oddene for Sintran Data © 2011]


Page 12

Product Information

Date Norsk Data Page 12 of 15
90.06.18

Product Name

Basic System Package for ND-5000 Systems

Product Number
380799A

Special Modification Patches (SM-patches)

SM-patches are patches for customers with special needs (the different SM-patches for SINTRAN vers. L is described below).

How to Implement

  1. Edit in the right patch number in the file PF-MODIF-L:FADM on user SYSTEM
  2. Run the mode job (spec-modif-patc)sm-start-patch-file:mode @MODE (SPEC-MODIF-PATCH)SM-START-PATCH-FILE:MODE
  3. Run through a SHUTDOWN procedure and do a @COLD-START

Example of what a PF MODIF:FADM file looks like:

PNI19  %Here the SM-patch I19 is implemented
@

List of SM-patches available on SINTRAN L.

PN284
PN283
PN262
PN231
PN252
PN248
PN235
PN233
PN214
PN193
PN189
PN180
PN171
PN170
PN169
PN168
PN156
PN154
PN119
PN082
PN004

ND-895560.1 EN


Scanned by Jonny Oddene for Sintran Data © 2011


Page 13

Product Information

Date Norsk Data Page 13 of 15
90.06.18
Product name Product number
Basic System Package for ND-5000 Systems 380799A

SPRINT SINTRAN Spooling System (211056A05)

  • Sprint will not accept documents stored under NOTIS-DS. Such documents must be moved to SINTRAN if they are to be printed.
  • If remote printing is to be successful, the SSYOPEN routine in the SSYLIB library requires that the local system name corresponds to the first system name defined on the remote machine.

Installation of a New Printer Driver in SPRINT

The following sprint drivers could be installed from the disk:

----Not handling Open Lan----

PHILIPS-300 DP-55        EPSON-MX80  EPSON-RX80   DIABLO-1650
DIABLO-1610 DIABLO-630   TEC-F10     OLIVETTI     GEN-3024
EPSON-LX80  ELPHO-20     LINE-PRINTER           TELEX CANON-LBP8

----Handling Open Lan----

EPSON-MX80  EPSON-RX80   EPSON-LX80

ND-616cn
ND-720PP
ND-460TTP
ND-PSCRIPT
PHILIPS-300
CANON-LBP8
LINE-PRINTER
VISION SERVER

To start the installation program, log into user SYSTEM and give the command:

@(SPRINT-USER)IN-PRM

The rest of the procedure is self-explanatory.

If a printer driver is going to be installed from a diskette, the installation program has to be started from the diskette containing the printer driver and the installation program. When you are asked where to put the new printer driver(s), the user name must be SPRINT-USER (default answer is nd-operations).


ND-895560.1 EN

[Scanned by Jonny Oddene for Sintran Data © 2011]


Page 14

Product Information

Date Norsk Data Page 14 of 15
Product name Product number
Basic System Package for ND-5000 Systems 380799A

Redefining of OL-printers When You Have Installed a New Platform on Your System

  1. From user area SYSTEM use an editor to read the file
    SYMBOL-2-LIST:SYMB.

    • Find the text string F1731.
    • Write down the value corresponding to F1731 (on most systems the address will be 070322).
  2. @ABORT COSPO

  3. Exit the editor and type the following underlined text after the Sintran prompt:

SINTRAN-SERVICE-PROGRAM↔
*INSERT-IN-LOGICAL-UNIT-TABLE↔
LOGICAL UNIT NUMBER (OCT):23xx↔
    (23xx is the sintran logical device
    number in octal from S3-CONFIG)
INPUT OR OUTPUT? OUT↔
DATAFIELD ADDRESS (OCT):ffffff↔
    (ffffff is the data field address from
    step 1. above)
MEMORY? YES↔
IMAGE? YES↔
SAVE-AREA? YES↔
*EXIT↔
  1. Type the following underlined text:
@SET-PERIPHERAL-FILE "OL-<name>" <23xx>↔
    (OL-name is the printer’s OpenLan name)
@SET-FILE-ACCESS OL-<name> WA RWA RWA↔

@CREATE-NEW-VERSION OL-<name>:;x,0↔
    (x is the number of spooling files)
@SET-FILE-ACCESS OL-<name>:1,1,,,rwacd↔
  1. Step 3. and 4. have to be done for each OL-printer on your system.

  2. @SPRINT /START-SPRINT

  3. @START-SPOOLING COSMOS-SPOOLING

ND-895560.1 EN

[Scanned by Jonny Oddene for Sintran Data © 2011]


Page 15

Product Information

Date Norsk Data Page 15 of 15
Product name Product number
Basic System Package for ND-5000 Systems 380799A

EServer System Administration Menu

On this platform (A01) you have the possibility to have the EServer administration menu in two languages, English or Norwegian. To change from Norwegian to English or the other way around you have to do the following:

  • Log into UE-user SYSTEM
  • Call the User Environment profile manager by typing @UE-PMAN
  • Then you get into a menu where you are asked for user name, and there you put in SYSTEM.
  • Further down in the menu you are asked for language and here you have to put in the wanted language (Norwegian or English).
  • The menu system name is (SYSTEM)ES-MENU
  • To get out of the menu, press the EXIT button.

Defining of Extra Swap- and Segment-Files

If you need more swap- or segment-files you have to update two different files:

  • (ND-OPERATIONS)BM-PARAMETER-B:DATA
  • (MODE-FILES)USER-DISKS:MODE
  1. @PED (ND-OPERATIONS)BM-PARAMETER-B:DATA

    Here you put in the following:

    IMAGE-NO-COMPARE-FILE = (SWAP-USER)SWAP-FILE-<X>:SWAP
    for extra swap file, or
    IMAGE-NO-COMPARE-FILE = (SWAP-USER)SEGFIL<X>:DATA
    for extra segment file.
    (SWAP-USER) = Name of the user containing the
       SWAP or SEGMENT file
    <X> = SWAP or SEGMENT file number
    

  2. @PED (MODE-FILES)USER-DISKS:MODE

    At the end of this file you put in the following:

    @ND
    DELETE-SWAP-FILE (SWAP-USER)SWAP-FILE-<X>:SWAP
    DEFINE-SWAP-FILE (SWAP-USER)SWAP-FILE-<X>:SWAP
    EXIT
    

ND-895560.1 EN