Basic System Package for ND EServer is a part of the Basic System Package for ND EServer (ND-211731), which is a prepackaged system for the ND EServer with menu-oriented operation routines for easy operating.
Reason(s) for New Product or Version¶
The reason for this product is to give Supervisors and other persons responsible for system operation an easy and quick way to upgrade the basic software on all ND EServer models. This product is designed to be used when a new version/revision of the basic software on the ND EServer is required. All the software on this product is pre-packed and may easily be installed. This product will be installed and prepared by ND on all deliveries of ND EServer models.
Table of Contents¶
| Page | |
|---|---|
| 1 Prerequisites | 2 |
| 2 Dependencies | 2 |
| 3 Documentation | 2 |
| 4 Packing List | 3 |
| 5 Read this first. | 3 |
| 6 Manual installation procedure. | 3 |
| 7 Errors corrected | 8 |
| 8 Errors known but not corrected | 8 |
| 9 Limitations | 9 |
| 10 Products included | 10 |
| 11 General Information | 11 |
ND-895560.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 2¶
Product Information¶
Date: 90.06.18
Norsk Data
Page: 2 of 15
| Product name | Product number |
|---|---|
| Basic System Package for ND-5000 Systems | 380799A |
1 Prerequisites¶
The following things are required in order to use this product.
- Prerequisite for all ND EServer models:
- One of the following platform kits:
- ND-110966, ND-110967, ND-111194, ND-111195, ND-111196.
- Disk Restore (ND-211187 B)
- A scratch Streamer Cassette.
- One of the following platform kits:
2 Dependencies¶
The system disk must be divided into four subunits (DISC-4-SCSI-1), each with the directory size 77 Mbyte.
Only internal updates are allowed on PACK-BASIC on the ND EServer.
3 Documentation¶
There is one manual for the ND EServer describing different operation parts supported by a menu system, and how to maintain these operation parts. Necessary documentation for the product elements is included in the total delivery of the ND EServer (ND-870027 Basic Documentation Package for ND EServer).
The most important operation documentation:
| Guide | Code |
|---|---|
| COSMOS User Guide | ND-860163.4 |
| SPRINT User Guide | ND-860252.2 EN |
| ND EServer System Administrator Guide | ND-830147.1 EN |
| Backup Manager User Guide | ND-860276.2 EN |
| COSMOS Operator Guide | ND-830025.2 EN |
| OEM User Guide | ND-830101.1 EN |
| DOMINO SCSI Operator guide | ND-814009.1 EN |
| ND-LINKER User Guide & Reference | ND-860289.2 EN |
| COSMOS Operator Card | ND-899002.2 EN |
| COSMOS User Card | ND-899001.2 EN |
ND-895560.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 3¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.06.18 | 3 of 15 |
| Product name | Product number |
|---|---|
| Basic System Package for ND-5000 Systems | 380799A |
4 Packing List¶
ND-211731 A - 1 Streamer Cassette with Basic SW Package I for ND EServer.
5 Read This First¶
Rules concerning Es platform systems.
The Es platform consists of four directories:
PACK-BASIC -----> DISC-4-SCSI-1,0,0
PACK-MAIN -----> DISC-4-SCSI-1,0,1
PACK-EXTENSION -----> DISC-4-SCSI-1,0,2
PACK-APPLICATION -----> DISC-4-SCSI-1,0,3
a) PACK-BASIC contains system files and has to remain
as it is when delivered from NORSK DATA A.S.
Some few exceptions exist.
b) PACK-MAIN contains configuration files for the
system, USER-ENVIRONMENT and customer-defined
users. Available space is free for the customer to use.
c) PACK-EXTENSION contains your additional ND applications
such as NOTIS, SIBAS, TCP-IP and so on.
d) PACK-APPLICATION is reserved for the different
business units belonging to NORSK DATA and their
application packages.
NO-895560.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 4¶
Product Information¶
| Date | Norsk Data | Page 4 of 15 |
|---|---|---|
| Product name | Product number | |
| Basic System Package for ND-5000 Systems | 380799A |
6 Manual Installation Procedure¶
This procedure should be followed when a new version of the Basic System Package is to be installed.
+--------------------------------------------------+
| CAUTION! |
| |
| All software located on PACK-BASIC-A will be |
| destroyed and a new version of PACK-BASIC-A will |
| be restored from the streamer. On user SYSTEM |
| there may be files belonging to other products |
| than those listed in chapter 10 (libraries, init |
| files etc.). Backup of these files must be taken |
| before the disk is restored. |
+--------------------------------------------------+
- Preparations before stopping the ND EServer:
a) Check that the file
(MODE-FILES)DEF-PERIPHERALS:MODEcorresponds to your system before you take the system down.b) Save user files to a scratch streamer cassette using the Backup Manager:
- Insert a scratch streamer cassette into the streamer drive. - Log in as user SYSTEM and start the BACKUP-MANAGER from the ND EServer System Administrator menu option 3.0 (backup) or from SINTRAN by doing the command
@BM-OPERATOR-. - Use the backup setBACKUP-FILESto save not standard platform files to streamer. All files and users NOT listed in the file(PROG-FILES)EXCLUDE-FILES:SYMBwill be copied to the streamer cassette.When the new Basic System Package is installed, these files can be copied back to user SYSTEM on PACK-BASIC-A (ref. point 1h.).
Page 5¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.06.18 | 5 of 15 |
| Product name | Product number |
|---|---|
| Basic System Package for ND-5000 Systems | 380799A |
c) Passwords¶
Write down the following passwords:
- SYSTEM (sintran password)
- MULTI-OE (user-environment password)
- SIBAS-MANAGER (user-environment password)
d) Perform a controlled shutdown of the ND EServer:¶
Log in to user SYSTEM and execute the command:
@MODE·(MODE-FILES)ES-SHUTDOWN:MODE
All configuration dependent system-files located on PACK-BASIC-A will be copied to user CONFIG-FILES on PACK-MAIN-SW.
Press STOP and MACL (Master Clear) buttons from the operator panel!
ND-895560.1 EN
Page 6¶
Product Information¶
| Date | Norsk Data | Page 6 of 15 |
|---|---|---|
| Product name | Product number | |
| Basic System Package for ND-5000 Systems | 380799A |
e) Install the new platform:¶
Insert the ND-211731A streamer cassette in the streamer drive.
Use Disk Restore version B to copy the streamer cassette to the system disk (Device: DISC-4-SCSI-1 unit:0 subunit:0).
Ref. PI sheet for Disk Restore (ND-211187 B).
Di-Re: RESTORE-DISK
| From (Directory/Volume | VOLUME |
| Source device name | STREAMER-1 |
| Source device unit | 0 |
| Retension(Yes/No) | YES |
| Compare (Yes/No) | YES |
| Destination device name | DISC-4-SCSI-1 |
| Destination device unit | 0 |
| Destination device subunit | 0 |
Retension
Mounted volume is: PACK-BASIC-A
on device: STREAMER-1,0
Give command (Continue/Retry/Cancel) : CONTINUE
Searching
-------------- Image found -------------------
Volume : PACK-BASIC-A
Reel : 1
Index : 1
Computer :
Directory: PACK-BASIC-A
Device : DISC-4-SCSI-1,0,0
Pages : 37685
Backed up: 90-06-10
Control : RdFc
----------------------------------------------
Confirm start of restore (Start/Next-Image/Cancel) : START
Directory: PACK-BASIC-A
detected on the device: DISC-4-SCSI-1,0,0
Give command (Retry/Overwrite/Cancel): OVERWRITE
Copying (DMA)
Rewinding
Comparing
This takes about 22 minutes with compare.
ND-895560.1 EN
[Scanned by Jonny Oddene for Sintran Data © 2011]
Page 7¶
Product Information¶
| Date | Norsk Data | Page 7 of 15 |
|---|---|---|
| Product name | Basic System Package for ND-5000 Systems | Product number |
| 380799A |
When this operation is finished continue with next point.
f) Initialising the new platform:
Press MCL (Master Clear) and the LOAD buttons on the Operator panel.
Then the following text will appear on the terminal:
------------------------------------------------------
! Please continue with next point in the installation !
! procedure in the PI sheet. !
------------------------------------------------------
- Customize the new platform:
g) Platform preparations
Start the installation program
@PLATFORM-INST~
and answer the questions according to your software and hardware on the system.
********************************************************
The installation program will now prepare the system according
to your specifications.
********************************************************
h) Reinstall the backup of the files backed up with the RESTORE-FILES job in BACKUP-MANAGER.
@BM-OPERATOR~
Files saved in point (1b) will be restored on the new PACK-BASIC-A
i) Do a COLD-START
@COLD-START~
The system is now running through a complete COLD-START and WARM-START.
When the system is restarted the following text is displayed on the console printer and on the console:
>> The ND EServer is available
ND-895560.1 EN
Page 8¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.06.18 | 8 of 15 |
| Product name | Product number |
|---|---|
| Basic System Package for ND-5000 Systems | 380799A |
The installation of the basic platform is now complete and ready to operate with a new version of the basic software.
CAUTION!
Remember to take a complete backup of the System disk PACK-BASIC-A, PACK-MAIN-SW, PACK-EXTENSION and PACK-APPLICATION (PACK-APPLICATION is optional). This is for security reasons in case of disk problems later on.
7 Errors Corrected¶
All reported errors have been corrected except those listed in section 9.
8 Errors Known But Not Corrected¶
-
SPRINT Sintran spooling system (211056A05)
- If on startup of Sprint, device numbers 1032-1039 (and maybe others) are being used, Sprint will not be able to stop the SPRT programs which have reserved these device numbers. Consequently, Sprint will not be able to use the associated printers.
-
BACKUP Manager (211226B04):
- RESTART-USER in the menu is not fully corrected. It is not possible to do this against a remote server.
- Problems with treating EOF-status as OK after 'space-EOF' function. This is a problem for non-SCSI mag-tape drives when listing volumes on more tapes.
ND-895560.1 EN
Page 9¶
Product Information¶
| Date | Norsk Data | Page 9 of 15 |
|---|---|---|
| Product Name | Basic System Package for ND-5000 Systems | Product Number |
| 380799A |
9 Limitations¶
-
BACKUP Manager (211226 B04):
- Indexed files larger than 65000 pages cannot be copied by Backup Manager. (Contiguous files can be copied when logged in as user SYSTEM)
- When performing image copying in batch mode (for example, via BM-scheduler) you cannot copy the directory where the input and device output batch files for this job are located. (Normally the directory where user area SYSTEM and ND-OPERATIONS is located).
- You cannot copy TO a DOMINO/SCSI tape-device from a remote computer.
- Image backup from N100 disks to tape/GTS devices connected to DSS is not possible.
ND-895560.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 10¶
Product Information¶
| Date | Norsk Data | Page 10 of 15 |
|---|---|---|
Product name
Basic System Package for ND-5000 Systems
Product number
380799A
10 Products Included¶
| NDno/VERSION | SOFTWARE MODULE | SINTRAN USER |
|---|---|---|
| 250304 L07 | SINTRAN III/VSX-500 Standard system A | SYSTEM |
| 250360 L0D | SINTRAN III/VSX Patch File 106000 | SYSTEM |
| 211024 E01 | SINTRAN III Configuration program | SYSTEM |
| 210913 A00 | SINTRAN III Monitor Call Package | SYSTEM |
| 211846 A01 | SOFTWARE-KEYS | SYSTEM |
| 211305 B02 | ND-500(0) System Package for SINTRAN III/VSX L | |
| J05 ND-500/5000 Background Monitor | PROG-FILES | |
| K04 ND-500/5000 Swapper | SYSTEM | |
| C01 ND-500/5000 Place Library | SYSTEM | |
| 210534 B00 | JEC | SYSTEM |
| 210721 C01 | BRF-Linker | PROG-FILES |
| 210375 C00 | TELEFIX Files for User Sites | PROG-FILES |
| 210337 I05 | BACKUP-SYSTEM | PROG-FILES |
| 210455 G05 | VTM Tables | SYSTEM |
| 210319 H02 | ND-500 Linkage-Loader | BASIC-DOMAIN |
| 210511 D02 | ND-500 Exception Library | SYSTEM |
| 210080 J00 | PED Eng for ND-100 | SYSTEM |
| 210532 K00 | PED Eng for ND-500 | BASIC-DOMAIN |
| 211224 B01 | ND Linker for ND-500/5000 | BASIC-DOMAIN |
| 211229 A03 | Convert-Domain | BASIC-DOMAIN |
| 211322 C03 | DOMINO Maintenance Kit | DOMINO-UTILITY |
| 211321 C03 | NUCLEUS Maintenance Kit | DOMINO-UTILITY |
| 211479 A08 | DSS Basic System | SCSI-DOMINO |
| 211480 A08 | DSS Libraries | DSS-LIBRARIES |
| 211481 A06 | DSS Test programs | DOMINO-UTILITY |
| 210335 H00 | Symbolic Debugger for ND-500/5000 | SYSTEM |
| 210336 F01 | Symbolic Debugger for ND-110 | SYSTEM |
| 211226 B04 | Backup Manager | BACKUP-MANAGER |
| 210374 F03 | COSMOS Basic module | COSMOS-BASIC |
| 210580 B03 | COSMOS Ethernet option | COSMOS-BASIC |
| 211075 C03 | File Manager | OE-USER |
| 211073 A04 | File System Verification | OE-USER |
| 211070 A01 | User Area Manager | OE-USER |
| 211078 A01 | Multi-Machine Operator Environment | OE-USER |
| 211074 B01 | Performance Monitor for ND-100/500(0) | OE-USER |
| 211056 A05 | SPRINT Spooling System | SPRINT-USER |
ND-895560.1 EN
[Scanned by Jonny Oddene for Sintran Data © 2011]
Page 11¶
Product Information¶
| Date | Norsk Data | Page 11 of 15 |
|---|---|---|
| 90.06.18 | Product Information |
| Product name | Product number |
|---|---|
| Basic System Package for ND-5000 Systems | 380799A |
11 General Information¶
-
DSS Basic System (211479 A08):
- Device parameters should be set with DP-SERVICE for some devices.
Command: CHANGE-PARAMETERS
These are:
CDC disks: Device settle time = 10 sec Device power up time = 90 sec GTS, STC tapes: No synchronous transfer GTS tapes: No. of retries on aborted command = 0 GTS tapes: Abort command allowed = NORemember also when defining the device GTS that the device code = 1.
-
SINTRAN III patches.
When it is necessary to install SINTRAN from floppies.
In addition to the patch file
106000the file(SYSTEM)SINTRAN-PATCHES:MODEhas to be run as a mode job after the standard patch file. This file includes additional patches for SINTRAN that is NOT included in the patchfile106000.When a new SINTRAN with patches is installed do the following:
@COLD-STARTLog in and enter the main directory by typing:
@ENTER-DIRECTORY,,DISC-4-SCSI-1,0,0Log out and log in as user SYSTEM:
@SINTRAN-SERVICE @SET-COLDSTART-MODE-FILE PACK-BASIC-A,DISC-4-SCSI-1,0,0 @HENT-MODE:MODE @HENT-OUTPUT:LIST @EXIT @S3-CONFIG GENERATE @COLD-START
ND-895560.1 EN
[Scanned by Jonny Oddene for Sintran Data © 2011]
Page 12¶
Product Information¶
| Date | Norsk Data | Page 12 of 15 |
|---|---|---|
| 90.06.18 |
Product Name¶
Basic System Package for ND-5000 Systems
| Product Number |
|---|
| 380799A |
Special Modification Patches (SM-patches)¶
SM-patches are patches for customers with special needs (the different SM-patches for SINTRAN vers. L is described below).
How to Implement¶
- Edit in the right patch number in the file
PF-MODIF-L:FADMon user SYSTEM - Run the mode job
(spec-modif-patc)sm-start-patch-file:mode @MODE (SPEC-MODIF-PATCH)SM-START-PATCH-FILE:MODE - Run through a SHUTDOWN procedure and do a
@COLD-START
Example of what a PF MODIF:FADM file looks like:¶
PNI19 %Here the SM-patch I19 is implemented
@
List of SM-patches available on SINTRAN L.¶
PN284
PN283
PN262
PN231
PN252
PN248
PN235
PN233
PN214
PN193
PN189
PN180
PN171
PN170
PN169
PN168
PN156
PN154
PN119
PN082
PN004
ND-895560.1 EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 13¶
Product Information¶
| Date | Norsk Data | Page 13 of 15 |
|---|---|---|
| 90.06.18 |
| Product name | Product number |
|---|---|
| Basic System Package for ND-5000 Systems | 380799A |
SPRINT SINTRAN Spooling System (211056A05)¶
- Sprint will not accept documents stored under NOTIS-DS. Such documents must be moved to SINTRAN if they are to be printed.
- If remote printing is to be successful, the SSYOPEN routine in the SSYLIB library requires that the local system name corresponds to the first system name defined on the remote machine.
Installation of a New Printer Driver in SPRINT¶
The following sprint drivers could be installed from the disk:
----Not handling Open Lan----
PHILIPS-300 DP-55 EPSON-MX80 EPSON-RX80 DIABLO-1650
DIABLO-1610 DIABLO-630 TEC-F10 OLIVETTI GEN-3024
EPSON-LX80 ELPHO-20 LINE-PRINTER TELEX CANON-LBP8
----Handling Open Lan----
EPSON-MX80 EPSON-RX80 EPSON-LX80
ND-616cn
ND-720PP
ND-460TTP
ND-PSCRIPT
PHILIPS-300
CANON-LBP8
LINE-PRINTER
VISION SERVER
To start the installation program, log into user SYSTEM and give the command:
@(SPRINT-USER)IN-PRM
The rest of the procedure is self-explanatory.
If a printer driver is going to be installed from a diskette, the installation program has to be started from the diskette containing the printer driver and the installation program. When you are asked where to put the new printer driver(s), the user name must be SPRINT-USER (default answer is nd-operations).
ND-895560.1 EN
[Scanned by Jonny Oddene for Sintran Data © 2011]
Page 14¶
Product Information¶
| Date | Norsk Data | Page 14 of 15 |
|---|---|---|
| Product name | Product number | |
| Basic System Package for ND-5000 Systems | 380799A |
Redefining of OL-printers When You Have Installed a New Platform on Your System¶
-
From user area SYSTEM use an editor to read the file
SYMBOL-2-LIST:SYMB.- Find the text string F1731.
- Write down the value corresponding to F1731 (on most systems the address will be 070322).
-
@ABORT COSPO -
Exit the editor and type the following underlined text after the Sintran prompt:
SINTRAN-SERVICE-PROGRAM↔
*INSERT-IN-LOGICAL-UNIT-TABLE↔
LOGICAL UNIT NUMBER (OCT):23xx↔
(23xx is the sintran logical device
number in octal from S3-CONFIG)
INPUT OR OUTPUT? OUT↔
DATAFIELD ADDRESS (OCT):ffffff↔
(ffffff is the data field address from
step 1. above)
MEMORY? YES↔
IMAGE? YES↔
SAVE-AREA? YES↔
*EXIT↔
- Type the following underlined text:
@SET-PERIPHERAL-FILE "OL-<name>" <23xx>↔
(OL-name is the printer’s OpenLan name)
@SET-FILE-ACCESS OL-<name> WA RWA RWA↔
@CREATE-NEW-VERSION OL-<name>:;x,0↔
(x is the number of spooling files)
@SET-FILE-ACCESS OL-<name>:1,1,,,rwacd↔
-
Step 3. and 4. have to be done for each OL-printer on your system.
-
@SPRINT /START-SPRINT -
@START-SPOOLING COSMOS-SPOOLING
ND-895560.1 EN
[Scanned by Jonny Oddene for Sintran Data © 2011]
Page 15¶
Product Information¶
| Date | Norsk Data | Page 15 of 15 |
|---|---|---|
| Product name | Product number | |
| Basic System Package for ND-5000 Systems | 380799A |
EServer System Administration Menu¶
On this platform (A01) you have the possibility to have the EServer administration menu in two languages, English or Norwegian. To change from Norwegian to English or the other way around you have to do the following:
- Log into UE-user SYSTEM
- Call the User Environment profile manager by typing
@UE-PMAN - Then you get into a menu where you are asked for user name, and there you put in SYSTEM.
- Further down in the menu you are asked for language and here you have to put in the wanted language (Norwegian or English).
- The menu system name is
(SYSTEM)ES-MENU - To get out of the menu, press the EXIT button.
Defining of Extra Swap- and Segment-Files¶
If you need more swap- or segment-files you have to update two different files:
(ND-OPERATIONS)BM-PARAMETER-B:DATA(MODE-FILES)USER-DISKS:MODE
-
@PED (ND-OPERATIONS)BM-PARAMETER-B:DATAHere you put in the following:
IMAGE-NO-COMPARE-FILE = (SWAP-USER)SWAP-FILE-<X>:SWAP for extra swap file, or IMAGE-NO-COMPARE-FILE = (SWAP-USER)SEGFIL<X>:DATA for extra segment file. (SWAP-USER) = Name of the user containing the SWAP or SEGMENT file <X> = SWAP or SEGMENT file number -
@PED (MODE-FILES)USER-DISKS:MODEAt the end of this file you put in the following:
@ND DELETE-SWAP-FILE (SWAP-USER)SWAP-FILE-<X>:SWAP DEFINE-SWAP-FILE (SWAP-USER)SWAP-FILE-<X>:SWAP EXIT
ND-895560.1 EN