Page 1¶
Product Information¶
| Product name | Product number |
|---|---|
| UNIQUE UNIQUICK SIBAS | 210872C |
| for ND-500/5000 |
Description of Product¶
Easy, interactive application generator for UNIQUE-II SIBAS.
Reason(s) for Release¶
Revision C13. Error correction and some modifications.
Revision C14. Error correction.
Minor significant changes in this PI-sheet are marked with '*'.
Table of Contents¶
| Prerequisites | 2 |
| Dependencies | 3 |
| Documentation | 4 |
| Installation procedure | 5 |
| Modifications | 9 |
| Errors corrected | 11 |
| Errors known but not corrected | 11 |
ND-895185.1B EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 2¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 89.11.14 | 2 of 11 |
Product Name: UNIQUE UNIQUICK SIBAS for ND-500/5000
Product Number: 210872C
1 Prerequisites¶
The following things are required in order to use this product.
1.1 Hardware Prerequisites¶
The following hardware must be present for this product to be used:
CPU type (any of the following):
- 500/2 (The BCD hardware must be present).
- 5000
Other hardware:
None
1.2 Software Prerequisites¶
The following software must be installed on the system for this product to be used:
Operating System:
| Name | Version/Revision |
|---|---|
| SINTRAN-III | >= I |
| >= K WM500 if new domain format |
Other Software:
| Product Name | Product Number |
|---|---|
| SIBAS-II, or SIBAS/R, Software keys | 210340F, 211212A/B*, 210507B |
| UNIQUE Software Key | |
| UNIQUE Text System, version >= C10 | 211005C |
| Linkage Loader for ND-500/5000 | 210319H |
| ND-LINKER* | 211224B |
| UE-PLIB, version >= C03*, included in: | 210518 |
| NOTIS-WP (or another editor) | 210526M/N/O* |
ND-895185.1B EN
Page 3¶
Product Information¶
| Date | 89.11.14 |
| Norsk Data | Page 3 of 11 |
| Product name | Product number |
| UNIQUE UNIQUICK SIBAS for ND-500/5000 | 210872C |
1.3 Other Prerequisites¶
The following are necessary for this product to be used.
Minimum Permanent Mass Storage:
| User | Space (pages) | Number of files |
|---|---|---|
| DIALOG-SYS | 70 | 1 |
| \<any user> | 360 | 15 |
- Requirements regarding internal devices: None
- Requirements regarding batch processors: None
2 Dependencies¶
In addition to the above listed hardware and/or software prerequisites, the following dependencies exist between this and other products. The hardware and software listed here may, for example, be necessary to use the product's full functionality.
2.1 Hardware Dependencies¶
None
2.2 Software Dependencies¶
| Product name | Product number |
|---|---|
| Unique-II SIBAS for ND-500/5000 | 210730C |
Nature of dependency
Revision C10 or later must be installed to be able to compile and run the applications generated with UNIQUICK.
ND-895185.1B EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 4¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 89.11.14 | 4 of 11 |
UNIQUE UNIQUICK SIBAS for ND-500/5000¶
| Product number |
|---|
| 210872C |
Product Details¶
User Environment¶
| Product name | Product number |
|---|---|
| User Environment | 210518 |
Nature of dependency
When User Environment is active, version CO3* or later is required.
NOTIS-WP¶
| Product name | Product number |
|---|---|
| NOTIS-WP | 210526M/N |
Nature of dependency
When using NOTIS-WP for editing UNIQUE-II applications, version M or later is required. When using version N or later, please see chapter 5.4, Other Modifications.
Documentation¶
Included (distributed free with product)
| Title | Number |
|---|---|
| DIALOGUE UNIQUICK User Guide | ND-860240.2 EN |
| DIALOGUE UNIQUICK Brukerveiledning | ND-860240.2 NO |
ND-895185.1B EN
[Scanned by Jonny Oddene for Sintran Data © 2011]
Page 5¶
Product Information¶
Date: 89.11.14
Norsk Data
Page 5 of 11
Product Name¶
UNIQUE UNIQUICK SIBAS for ND-500/5000
Product Number¶
210872C
Installation Procedure¶
4.1 Automatic Installation¶
4.1.1 Preparations¶
Prior to the installation, verify the following:
- Ensure that the user areas specified in Chapter 1.3 exist with the required number of free pages and free files. If not, find a directory with enough space to hold the user areas. The installation program will try to allocate space whenever needed, but you may need to specify on which directory to create user areas.
- The following files will be loaded/linked to UNIQUICK:
| Abbrev. | File Name | Default User Area(s) |
|---|---|---|
| SIBAS library | SIB-LIB | SIB-500 |
| UE library | UE-PLIB | USER-ENVIRONMENT |
Check where these files are installed. If not installed on the default user area, the installation program will ask where to find these files.
- If you already have a version of UNIQUICK installed, make sure it is not defined as a standard domain. Delete it prior to the installation.
- Ensure that your configuration fulfills all other requirements mentioned in Chapter 1 and 2.
----------------------------------------------------------
NOTE:
TO INSTALL UNIQUICK ON AN ND-500/5000 MACHINE WITH THE NEW
ND-LINKER, THE NON-AUTOMATIC INSTALLATION PROCEDURE MUST BE USED
(SEE CHAPTER 4.2).
----------------------------------------------------------
ND-895185.1B EN
Page 6¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 89.11.14 | 6 of 11 |
| Product name | Product number |
|---|---|
| UNIQUE UNIQUICK SIBAS FOR ND-500/5000 | 210872C |
4.1.2 Installation from Floppy¶
- Put the diskette 210872C
-XX-01D into the floppy drive. - Log in to user area SYSTEM.
- Enter directory 210872C-XX-01D.
- Run the INSTALL program on the diskette.
Example: How to enter the directory and start the installation program (user input is underlined).
@ENTER-DIRECTORY 210872C-XX-01D FLOPPY-DISC-1 0_
@(210872C:FLOPPY-USER)INSTALL_
The following screen will appear:
|--------------------------------------------------|
| INSTALLATION |
| UNIQUE SIBAS ND500 VERSION Cxx |
|--------------------------------------------------|
| Unique A/S Date: 24-JUN-88 |
| --> Initialising - please wait --> |
| --> Sintran version:K Revision:3100 Generated:15-MAY-86 |
| --> Cpu number :6200 |
| |
| You may ESCAPE at any time to abort the installation procedure. |
| Choose one of the following options: |
| |
| 1 - CREATE : Create user and allocate space |
| 2 - COPY : Copy files from floppies |
| 3 - LOAD : Make and run load procedure |
| 4 - DUMP : Define system as standard domain |
| 0 - EXIT : |
| |
| Make your selection (1/2/3/4/0): |
|--------------------------------------------------|
The installation program will ask you for information (user areas, directory names etc) but will usually suggest reasonable default values. You can answer these questions by typing ↵ (the ENTER key) thus using the default value.
You may install UNIQUICK on any user area, but DIALOG-SYS is used as default in the installation program.
ND-895185.1B EN
Page 7¶
Product Information¶
| Date | Norsk Data |
|---|---|
| 89.11.14 | Page 7 of 11 |
| Product name | Product number |
|---|---|
| UNIQUE UNIQUICK SIBAS for ND-500/5000 | 210872C |
The installation program can do the following:
- CREATE: Create a new user area (or verify an existing one) for UNIQUICK.
- COPY: Copy all files from the floppy to the desired user area.
- LOAD: Write the load procedure and load the UNIQUICK ND-500 domain.
- DUMP: Dump UNIQUICK as a standard domain.
- EXIT: Leave the installation program and return to SINTRAN.
The first time, run all the tasks 1-4, one at a time, in sequence.
To reload UNIQUICK, run tasks 3 and 4. To re-dump UNIQUICK, run task 4.
When selecting the CREATE or COPY option, and an (old) version exists on this user area, you are asked if these files should be deleted. You may answer Yes, No or Manually. When answering YES, program files, domain files, .MODE and .LIST files of current and previous versions/revisions will be deleted. Afterwards the program checks if there are enough free pages on the user area.
When selecting the LOAD option, there are some questions that need an explanation:
LANGUAGE: 'Language to be used if UE is not active? /NO/'
By default UNIQUICK will use the language found in the user profile in User Environment. The answer to this question selects the language to be used if UE is NOT active on the terminal running UNIQUICK.
SW-CONFIG: 'Should it be legal for users to define their own SW-CONFIG:SYMB file? /N/'
Answer Y if you want to allow users to have a personal copy of the configuration file.
ND-895185.1B EN
Page 8¶
Product Information¶
| Date | Norsk Data | Page 8 of 11 |
|---|---|---|
| Product name | Product number | |
| UNIQUE UNIQUICK SIBAS for ND-500/5000 | 210872C |
4.1.3 Subsequent Installation¶
If at a later date you want to reload or re-dump UNIQUICK, you can use the installation program that is automatically copied from the floppy during the first installation. To re-run the installation program, log in to user area SYSTEM and type:
@(DIALOG-SYS)QUICK-IN-S5-C-
To reload UNIQUICK, run tasks 3 and 4. To re-dump UNIQUICK, run task 4.
You may of course also reuse the previously created load/dump procedures (:MODE).
4.2 Non-Automatic Installation¶
Create a user area with the number of pages mentioned before and copy all the :NRF and :MODE files from the floppy into it.
Loading with Linkage Loader:¶
Log in to the user area containing the :NRF files. Edit the file QUIC-LOAD-S5-C:MODE to suit your installation and run it by typing:
@MODE QUIC-LOAD-S5-C:MODE "QUIC-LOAD-S5-C:LIST"↩
Loading with ND Linker:¶
Log in to the user area containing the :NRF files. Edit the file QUIC-DOM-C:MODE to suit your installation and run it by typing:
@MODE QUIC-DOM-C:MODE "QUIC-DOM-C:LIST"↩
Define Standard Domain:¶
Update the file QUIC-DUMP-S5-C:MODE and run it from user SYSTEM. Update the system startup file (HENT-MODE:MODE) if you want UNIQUICK to be defined as standard domain after a cold-start.
ND-895185.1B EN
[Scanned by Jonny Oddene for Sintran Data © 2011]
Page 9¶
Product Information¶
| Date | Norsk Data | Page 9 of 11 |
|---|---|---|
| Product Name | [blank] | Product Number |
| UNIQUE UNIQUICK SIBAS for ND-500/5000 | [blank] | 210872C |
5 Modifications¶
5.1 New Functions/Commands¶
Revision C10
- UNIQUICK has been rewritten with a new user interface and new application generating routines.
- Advanced applications can be made using many tables (owner-member structures and join structures) and most UNIQUE-II field functions are available.
- The word "Letter" (language dependent) is displayed in the status line if you have some unread electronic mail (NOTIS-ID).
- New terminology has been introduced in the DIALOGUE family. UNIQUICK uses the new terminology.
- UNIQUICK now reads the parameter 'prefix-source=' from the SW-CONFIG file, under 'system-name:
' or 'system-name:@'. 'System name:@' denotes parameters valid for all UNIQUE systems.
- There is an additional configuration parameter, 'UNIQUE-ON-LINE=', which is not documented in the manual. This is used to tell UNIQUICK the name of UNIQUE-II if the standard name is not used.
Example of use:
SYSTEM-NAME: @
UNIQUE-ON-LINE : UNIQ-II-SIBAS
- If the file (J)UNIQUICK-C-HEAD:INCL can be opened it is used to make a heading for the application. In addition, for each ^ character found, the application name is inserted.
Example of UNIQUICK-C-HEAD:INCL:
+----------+---+
| Unique-II | ^ |
+----------+---+
ND-895185.1B EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 10¶
Product Information¶
| Date 89.11.14 | Norsk Data | Page 10 of 11 |
|---|---|---|
| Product name | UNIQUE UNIQUICK SIBAS for ND-500/5000 | |
| Product number | 210872C |
5.2 Changed Functions/Commands¶
Revision C13
- The question on whether to create a
:UCOMfile has been removed. UNIQUE-II handles:UCOMfile creation automatically. - The UNIQUE-II password tables are now only available if running from Sintran user area SYSTEM.
5.3 Removed Functions/Commands¶
None
5.4 Other Modifications¶
Revision C13
-
Due to changes in the S-format required in different versions of the NOTIS products, a new file must be present on user DIALOG-SYS. This file is named
UQ-ND-S:INIand must have public read access.All S-format files produced by UNIQUE products will have the same S-format header as the file
(DIALOG-SYS)UQ-ND-S:INI.UQ-ND-S:INIis an 'empty' file containing only an S-Format header matching the version of NOTIS-WP you are using on your machine. By storing the S-Format header in a file, it is possible for you to define the default settings and rulers. UNIQUE will read the default header from this user defined file, if it exists.If you start using a version of NOTIS-WP with a new S-Format, e.g. going from WP version M to N, just repeat the procedure described below and UNIQUE will produce documents readable by the new WP version.
You have to install/create this file manually:
1. Log in on user area DIALOG-SYS. 2. Start NOTIS-WP. 3. Use the internal menus in WP to set the wanted default values. 4. Make sure you define it to be an S-Format document. 5. Type some blanks so WP will store it as a document. 6. Save this 'empty' document to the file "UQ-ND-S:INI". 7. Set public access to READ: @set-file-access UQ-ND-S:INI R R,,
ND-895185.1B EN
Scanned by Jonny Oddene for Sintran DATA © 2011
Page 11¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 89.11.14 | Page 11 of 11 |
| Product name | Product number |
|---|---|
| UNIQUE UNIQUICK SIBAS for ND-500/5000 | 210872C |
6 Errors Corrected¶
The product diskette contains a list of the errors corrected in the current and previous revisions (filename QUICK-ERRLOG-
7 Errors Known But Not Corrected¶
Revision C13/C14¶
- The LEGAL-VALUES() function is written out before the KEY() function.
- Two joins from the same column will fail, only one will be included in the :UNIQ file.
ND-895185.1B EN
Scanned by Jonny Oddene for Sintran Data © 2011