Page 1¶
Product Information¶
Product Name¶
ND tpServer Upgrade C02
Product Number¶
382300C01
Description of Product¶
This Patch Kit for the ND tpServer Platform version C (upgrading from version C01 to C02) is part of the Basic System Package for the ND tpServer (211560).
The Basic System Package is a prepackaged system for the ND tpServer with menu-oriented operation routines for easy operation.
The following products are updated with this Patch Kit:
| Code | Version | Product |
|---|---|---|
| 250306 | N01 | SINTRAN III/VSX Standard Version C (patch file version 2200) |
| M05 | ND-500/5000 Swapper | |
| 211226 | B05 | Backup Manager |
| 220001 | B07 | SIBAS/R including updated SIBAS SQL Server |
| 211455 | A06 | SIBAS Manager for ND-500/5000 |
| 210794 | E04 | NOTIS-DS for ND-500/5000 |
| 210156 | A07 | Sprint Spooling System |
| 210518 | E00 | User Environment |
| 211327 | D01 | TCP/IP Basic Module III |
| 211847 | B01 | ND-5830/5850 Microprogram |
| 211276 | F01 | ND-5800 Microprogram |
| 211275 | F01 | ND-5700 Microprogram |
| 211274 | E03 | ND-5500 Microprogram |
| 211273 | E03 | ND-5400 Microprogram |
| 212036 | A02 | UPS Server |
Reason(s) for New Product or Version¶
The purpose for this product is to replace some basic products in the platform system as well as to correct the errors discovered since version C01 of the ND tpServer Platform.
Table of Contents¶
| Content | Page |
|---|---|
| 1 Read this first | 2 |
| 2 Packing List | 3 |
| 3 Manual Installation Procedure | 3 |
| 4 Errors Corrected | 11 |
| 5 Errors Known but not Corrected | 21 |
| 6 Modifications | 22 |
| 7 Installing Special Modification Patches | 23 |
| 8 General Information | 24 |
| 9 Files modified or replaced by this Patch Kit | 29 |
Page 2¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
1 Read This First¶
The following things are required in order to use this product.
- This Patch Kit requires version C01 of the Basic Software Package for ND tpServer. The Patch Kit is generated with a SINTRAN III/VSX Standard system C (250306N01) and a Patch file version 2200 (250306N01).
-
Software Keys (210507B)
After installing this Patch Kit, all previously installed software keys are lost and must be reinstalled. Ensure that the diskette(s) with all necessary software keys are available before you start installation of this Patch Kit. UNIQUE is a product which requires a software key.
-
Output to a connected printer.
By changing the variable TINFO, you can choose if you want the output to the console to be written on a printer or on the terminal.
TINFO = 0 : the output will be written on the terminal
TINFO = 20 : the output will be routed to a connected printerAfter installation of this Patch Kit, TINFO is set to 20.
If you do not have a printer connected to the console terminal, all output will disappear.To change TINFO, the following procedure should be used:
@SINTRAN-SERVICE-PROGRAM~ *CHANGE-DATAFIELD I I N Y Y~ TINFO/ nnn 0~ (or 20) *EXIT~
- Prerequisite for all ND tpServer models:
- Console terminal
- 310 Mbyte System disk divided into two directories:
- PACK-BASIC-C (DISC-2-SCSI-1,0,0)
- PACK-MAIN-SW (DISC-2-SCSI-1,0,1)
- Streamer drive (155 Mbyte)
Page 3¶
Product Information¶
| Page 3 of 35 | Product Information |
|---|---|
| Product name | Product number |
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
2 Packing List¶
- 1 Streamer Cassette including all files necessary for this upgrade. (module no. 382300C01).
3 Manual Installation Procedure¶
+--------------------------------------------------------+
| CAUTION! |
| |
| Before you start this installation procedure, ensure |
| that you have an image backup of PACK-BASIC-C and |
| PACK-MAIN-SW. |
| Set the system unavailable and get all users to stop |
| working on the machine. |
+--------------------------------------------------------+
-
Check the Size and Number of Files for Some User Areas
This is a job that must be done manually.
The directory PACK-BASIC must have at least 1200 unreserved pages.
User area Requirement PACK-BASIC-C:RT must have 1100 free pages. PACK-BASIC-C:SYSTEM must have 1100 free pages and 13 free file entries. User area PACK-MAIN-SW:RT must have no files and no space. Files on this user must either be moved to user PACK-BASIC:RT or be deleted. When all files are deleted, use the command @TAKE-USER-SPACE to remove all user space from PACK-MAIN-SW:RT.
-
Make a Note of the Password for User Area SYSTEM
You need the SINTRAN password for user area SYSTEM during the installation of this Patch kit.
-
Make a Note of the Password for User SIBAS Manager
You need the User-Environment password for user SIBAS Manager during the installation of this Patch kit.
Page 4¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
4. Log in as User System and Do a Controlled Shutdown of the Machine¶
@MODE (MODE-FILES)SYSTEM-SHUTDOWN:MODE,,,
5. Copy the First 7 Files from the Streamer Cartridge¶
Insert the streamer cartridge into the drive.
Log in on user area SYSTEM and start the BM-OPERATOR.
@BM-OPERATOR↲
BmOp: COPY
Object Copy method Incremental
SINTRAN- FILE- NO-
From Volume name Computer name Device name U S Control
VOLUME- TPSERVER-C02- STREAMER-1- 0-
To Computer name Directory name User area Mode
DIRECTORY- PACK-BASIC- SYSTEM- Of,Nc↲
Selection File name Selection date
INCLUDE-
Select execution mode (Manual/Stop-on-error/Automatic): MANUAL↲
Reel: 01 Volume: TPSERVER-C02 Directory: TP-PLATFORM.TP-C02
| Task | Status |
|---|---|
| COLD-START-SEQ:MODE | START |
| SHORT-HENT:MODE | START |
| BEFORE-COPY:MODE | START |
| BM-OPERATOR-B05:DOM | START |
| BM-OPERAT-XX-B05:SEG | START |
| LIST-IMPLEMENTED:PROG | START |
| RAM-SCRATCH:MODE | START |
| REMOVE-FILES:MODE | CANCEL |
Do you really want to ABORT the operation (Yes/No): Yes↲
The streamer will rewind and you can push the EXIT-key to exit from the BM-OPERATOR and return to SINTRAN.
This operation takes about 3 minutes.
Scanned by Jonny Oddene for Sintran Data © 2022
Page 5¶
Product Information¶
| Product name | ND tpServer Platform Upgrade version C01 to C02 |
| Product number | 382300C01 |
6. @MODE COLD-START-SEQ:MODE,,,´¶
This MODE-job will prepare the COLD-START to automatically start the file SHORT-HENT:MODE.
The output from the SHORT-HENT:MODE you will find on the file HENT-OUTPUT:LIST.
This procedure takes only a few seconds.
7. PERFORM THIS STEP ONLY IF YOU ARE USING THE RAM DISK FEATURE¶
To find out if you are using this feature, you can use the command
@LIST-USER to check if user area SCRATCH-RAM exists on your system.
If you are not using the RAM disk feature, skip to step 8.
Execute the command:
@RAM-SCRATCH:MODE,,,´
This MODE-JOB will set up the memory configuration to allow part of memory to be used as a RAM disk.
8. @RESTART-SYSTEM¶
NOTE: Automatic start of the SHORT-HENT:MODE file is implemented.
Do NOT abort this job with the ESCAPE-key!
On normal termination, this sequence will finish with the message:
-- SYSTEM IS AVAILABLE, AND READY FOR PATCHING. --
If this sequence finishes with only the message: - Exit -
you should inspect the file (SYSTEM)HENT-OUTPUT:LIST to determine what went wrong and correct this.
This procedure takes about 10 minutes.
Log in as user area SYSTEM (without giving any password).
896058 EN 4
Scanned by Jonny Oddene for Sintran Data © 2022
Page 6¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
9. @MODE BEFORE-COPY:MODE,"BEFORE-COPY:LIST"¶
This MODE-job will do some preparations on different users before you start copying from the streamer cartridge. Some files are deleted and some files are renamed.
This procedure takes about 3 minutes.
10. Copy All Files from the Streamer Cartridge¶
Insert the streamer cartridge into the drive if it is not already inserted.
Check that you are on user area SYSTEM, and start the program BM-OPERATOR.
@ND ()BM-OPERATOR~
BmOp: COPY
Object Copy method Incremental
SINTRAN~ FILE~ NO~
From Volume name Computer name Device name U S Control
VOLUME~ TPSERVER-CO2~ STREAMER-1~ 0~ ~ ~
To Computer name Directory name User area Mode
DIRECTORY~ PACK-BASIC~ ~ Of,Nc,Ce~
Selection File name Selection date
EXCLUDE~ (SYSTEM)BM-OPERAT~ ~
Select execution mode (Manual/Stop-on-error/Automatic): STOP-ON-ER
The streamer will rewind and you can push the EXIT-key to exit from the BM-OPERATOR and return to SINTRAN.
This operation takes about 15 minutes.
Page 7¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
11. New Microprogram for the ND-5000 CPU¶
New microprogram for the ND-5000 CPU is copied to the user area SYSTEM:
MICRO-5850-12012:DATA for ND-5850 CPU
MICRO-5830-12012:DATA for ND-5830 CPU
MICRO-5800-B34:DATA for ND-5800 CPU
MICRO-5700-B34:DATA for ND-5700 CPU
MICRO-5500-B34:DATA for ND-5500 CPU
MICRO-5400-B34:DATA for ND-5400 CPU
Copy the appropriate file to the file CONTROL-STORE:DATA.
To get the CPU type for the machine you can do this:
@ND
ND-5000: VERSION ↵
Subsystem part:
System part...:
Swapper.......:
Micro program.:
CPU type......:
Accp version..:
Module:
ECO no:
Delete the files not needed on your system.
Page 8¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
12. Modifying for Special Modification Reports (SM Reports)¶
If you do not want to run any SM reports, verify that the file (SYSTEM)PF-MODIF-N:FADM exists and consists of only one line containing the character @.
If you want to run some Special Modification patches, you must edit the file (SYSTEM)PF-MODIF-N:FADM before you run the file (SYSTEM)AFTER-COPY:MODE.
A list of Special Modification Reports is found on page 13.
The file (SYSTEM)PF-MODIF-N:FADM must contain the library mark for the SM report(s). After editing it should look like this (7-bit format):
PN031
PN035
@
If you want to install additional SM patches at a later stage, follow the procedure described on page 23.
13. @MODE READ-SEGMENT:MODE, "READ-SEGMENT:LIST"¶
This mode file does basic patching of the platform.
This step takes about 5 minutes.
14. @MODE AFTER-COPY:MODE, "AFTER-COPY:LIST"¶
This mode file does the final patching of the platform.
- SYSTEM INST-SPEC-MODIF:MODE
S3-CONFIG GENERATE
Check the file AFTER-COPY:LIST to find out if there is any error messages from the patching.
This procedure takes about 5 minutes.
Page 9¶
Product Information¶
| Product Name | Product Number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
15. Link Applications Using SIBAS/R to the New Version of the SIBAS Library¶
All applications using SIBAS/R must be linked to the new version of the SIBAS library (SIBR-b)SIBR-LIBRARY-B07:SEG.
Use the ND-Linker (in the example below, we assume that the application is called APPLICATION:DOM):
@LINKER
NDL(ADV): LINKER-SERVICE-PROGRAM
NDL(SRV): CHANGE-FILE-REFERENCES APPLICATION:DOM
Old string name: (SIBR-B)SIBR-LIBRARY-B06:SEG
New string name: (SIBR-B)SIBR-LIBRARY-B07:SEG
xx substitutions done in domain APPLICATION:DOM
NDL(SRV) EXIT
NDL(ADV) EXIT
16. Update Definition of Network Printers, If Necessary¶
This step applies if your system includes network printers (printers defined as OpenLAN printers in Sprint) with support for SINTRAN spooling queue and you want to change the definition of such printers.
Refer to the procedure on page 27 to update the definition of the printers with the address relevant to the N-version of SINTRAN III.
17. Cold-Start¶
NOTE: Automatic start of the HENT-MODE:MODE file is implemented. Do NOT abort this job with the ESCAPE-key!
Some information will appear on the console and the console printer informing the operator that the different software products are loaded. When the cold start sequence is finished, the system is automatically restarted.
Some information will appear on the console and the console printer informing the operator that the different software products are started. The same messages will appear during a normal warm start sequence.
When the system is restarted, the following text is displayed on the console printer and on the console:
>> The ND tpServer is available
The installation is now complete and the ND tpServer is ready to run with a new version of the basic software.
Page 10¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version CO1 to CO2 | 382300C01 |
18. @MODE (SYSTEM)REMOVE-FILES:MODE,...¶
When running this mode file, the following requirements apply:
- You must be logged in as a User Environment user defined as Supervisor.
- You must be logged in as user area SYSTEM.
This mode file will remove all files used during installation.
This file itself has to be removed with the command @DELETE-FILE REMOVE-FILES:MODE
┌─────────────────────────────┐
│ CAUTION! │
│ │
│ Remember to take a complete │
│ backup of the System disks │
│ (PACK-BASIC-C and │
│ PACK-MAIN-SW). │
│ This is for security │
│ reasons in case of disk │
│ problems later on. │
└─────────────────────────────┘
Page 11¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
4 Errors Corrected¶
All reported errors are corrected except those listed in section 5.
Errors corrected since revision C01 of the platform, are marked with a change bar.
SINTRAN III/VSX-500 Standard System C (250306N01)¶
The patch-file 2200 is included as 28 :BPUN files.
The file SM-PATCHES-2200:PATC includes all special modification patches.
- Patch-file 2200
| Report no. | Program | Subject | Symptom |
|---|---|---|---|
| 49 A | All | Stopping a terminal which has never been logged out. | Strange things may happen, for example Hang level 2, Hang level 1. |
| 48 C | Flush | Error in File-system Flush Program. | Overwriting the contents of a file-system data page in disk in special situation (Escape, disconnect in heavy compilation mode file). |
| 46 A | VSX/500 | Extended delay before accessing MF-memory needed for ND-5850/James combination. | Problems when starting ND-5850 directly from power off, multiport may be lost. |
| 45 A | File system | MON 251 - COPAG. No error code returned from routine. | Backup-System’s Destination Expansion Mode did not work. On error return from COPAG, the error code was zero, and the Backup-System command aborted. |
+-------------------------------------+
| |
| Comma |
| |
+-------------------------------------+
Page 12¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
Report: 44 A¶
- Program: A11
- Subject: Fatal error in Nucleus function NKGETINFO subfunction 5.
- Symptom: Unpredictable consequences, commands may behave strange, SINTRAN looping, stopping, etc.
Report: 43 A¶
- Program: File system
- Subject: Error in opening file with common access when it is already opened with ordinary access.
- Symptom: System loops or hangs on level 2.
Report: 41 A¶
- Program: A11
- Subject: Error in 5MTRANS monitor Call.
- Symptom: Read does not supply correct data when reading from disk.
Report: 40 A¶
- Program: A11
- Subject: STOP-TERMINAL when terminal to stop is in waiting state and the answer is Yes to remove it and to stop it.
- Symptom: The scratch file can be left opened.
Report: 39 A¶
- Program: A11
- Subject: Timing problem when restarting a process waiting for a disk transfer.
- Symptom: System hangs on level 2 with P-register in PMTRANS routine.
- Solution: Tolerance please! The process will "hang" but the system will continue running.
Report: 38 A¶
- Program: ND-500(0)
- Subject: Additional high address memory for ND-500(0).
- Symptom: Number of pages for additional high address memory is always zero (except the first time).
Report: 37 A¶
- Program: A11
- Subject: Output to MTAD when line is dead.
- Symptom: Hanging terminals and system may stop in ERRFATAL on level 12.
Page 13¶
Comma¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
Report no.: 36 A¶
Program: A11
Subject: User Environment version E automatic login and ND-500(0) stopped (or error).
Symptom: Erroneously logged in as SINTRAN user area USER-ENVIRONMENT.
Report no.: 35 A¶
Program: File system
Subject: Error in deleting large files on large directories.
Symptom: User entry showing wrong number of pages used, and bit file not properly updated.
Report no.: 34 A¶
Program: ND-500(0)
Subject: ND-500(0) lock timeout not correctly reported.
Symptom: System loops on level 2.
General Modification reports¶
Report no.: 3¶
Program: A11
Subject: UE-LOGIN fails and "NO SCRATCH FILE" is written. Same as report number 164 for SINTRAN III version M.
Special Modification reports¶
Report no.: 33 A¶
Program: A11
Subject: Removes 'END OF FILE' message after @COPY command. Same as report number 69 for SINTRAN III version M.
[Photo: Scanned by Jonny Oddene for Sintran Data © 2022]
Page 14¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
Report Details¶
Report No.: 31 A¶
- Program: File system
- Subject:
- The command LIST-ALL-OPEN-FILES gives the following error: The specified device is not a terminal (Special GTI).
Report No.: 30 A¶
- Program: FTX
- Subject:
- Special patch for FTX-system. The patch will start the RT-program FTXSK if disk transfer error occurs. Same as report number 185 for SINTRAN III version M.
Report No.: 26 A¶
- Program: All
- Subject:
- Problems with 8-bit I/O on terminals. Same as report number 78 for SINTRAN III version M.
Report No.: 25 A¶
- Program: All
- Subject:
- Make monitor call EXABS (335) available on ND-500/5000. Same as report number 67 for SINTRAN III version M.
Report No.: 23 A¶
- Program: DMA-printer
- Subject:
- Paper Instruction Command and character conversions on DMA printers. Same as report number 32 for SINTRAN III version M.
Report No.: 21 A¶
- Program: BP-2000 printer
- Subject:
- Paper Instruction Command and Character conversions on BP-2000 printer. Same as report number 35 for SINTRAN III version M.
Report No.: 20 A¶
- Program: Driver
- Subject:
- Special character in 8-bit mode will be accepted as XON character. The input character is masked with 177₈. Same as report number 152 for SINTRAN III version M.
Report No.: 19 A¶
- Program: VSX
- Subject:
- UPNOD 2000 switch, disconnect terminal when logging out. Same as report number 190 for SINTRAN III version M.
Scanned by Jonny Oddene for Sintran Data © 2022
Page 15¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
Report Details¶
Report no.: 18 A¶
- Program: VSX
- Subject: UPNOD 3000 switch, disconnect terminal when logging out. Same as report number 125 for SINTRAN III version M.
Report no.: 17 A¶
- Program: VSX
- Subject: Reduce interrupt load from HDLC connected to digital line, (for example British Telecom’s Kilostream). Same as report number 68 for SINTRAN III version M.
Report no.: 15 A¶
- Program: VSX
- Subject: Restart after buffer full on internal devices. Same as report number 43 for SINTRAN III version M.
Report no.: 14 A¶
- Program: A11
- Subject: Reduce maximum length of mail messages to 160 characters, to fit into X.29 buffer. Same as report number 83 for SINTRAN III version M.
Report no.: 13 A¶
- Program: A11
- Subject: Patch to remove the form feed after the spooling trailer. Same as report number 77 for SINTRAN III version M.
Report no.: 12 A¶
- Program: A11
- Subject: Patch to remove the form feed at the end of the spooling print if the spooling trailer is present. Same as report number 76 for SINTRAN III version M.
Report no.: 11 A¶
- Program: A11
- Subject: Patch to remove form feed at the start of the spooling print if the spooling header is present. Same as report number 75 for SINTRAN III version M.
Report no.: 10 A¶
- Program: A11
- Subject: Patch to remove the form feed after the spooling header. Same as report number 74 for SINTRAN III version M.
Page 16¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
Report Summaries¶
Report no.: 9 A¶
Program: A11
Subject: Patch to treat empty spooling form as normal string.
Same as report number 73 for SINTRAN III version M.
Report no.: 8 A¶
Program: A11
Subject: Spooling header with rotating alphabetic characters (instead of *) gives more even wear on character set.
Same as report number 72 for SINTRAN III version M.
Report no.: 7 A¶
Program: A11
Subject: How to remove one line feed between each document on printer with tractor feed. Same as report number 70 for SINTRAN III version M.
Report no.: 6 A¶
Program: A11
Subject: Patch to include terminals using 3270- or VIP-emulator in @TERMINAL-STAT list, or when MON TERST is used. Same as report number 62 for SINTRAN III version M.
Report no.: 5 B¶
Program: A11
Subject: How to drop DTR (Data Terminal Ready), when logging out. This applies to special devices not supplied by ND. Same as report number 31 for SINTRAN III version M.
Report no.: 2 A¶
Program: A11
Subject: Batch output file opened for "overwrite" and not "write-append". Same as report number 115 for SINTRAN III version M.
Page 17¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
ND-500/5000 Swapper Version M05¶
All known errors in previous revisions are corrected:
| Report no. | Title |
|---|---|
| - | Error causing Swapper fatal error code 4 has been corrected. Lock/unlock sequence problem during search of index buffer chain. |
| - | Error causing Swapper fatal error code 330₈ has been corrected. Lock/unlock sequence problem in page fault handling. This is probably the reason for fatal error 40₈ as well. |
| - | Error causing Swapper fatal error code 415₈ has been corrected. Improved error handling in ForceToAbsFree. |
User Environment (210518E00)¶
All known errors in the previous revision are corrected:
| Report no. | Title |
|---|---|
| 3 | Error when using library call ueChAcc. |
| 5 | Impossible to change password in a local domain with the version E of User Environment. |
| 6 | Wrong IP addresses in UE-FUNC and Terminal-Status. |
| 7 | Problem with invalid default user area. |
Page 18¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
ND-5830/5850 Microprogram (211847B01)¶
| Report no. | Title |
|---|---|
| - | The Call instruction has been changed to handle a false cache-hit in the instruction cache. |
| - | An error in NK send is corrected. Occasionally, this previously led to error code 21328 (Lock timeout). |
ND-5000 Microprograms¶
ND-5800 Microprogram (211276F01)
ND-5700 Microprogram (211275F01)
ND-5500 Microprogram (211274E03)
ND-5400 Microprogram (211273E03)
| Report no. | Title |
|---|---|
| - | An error in the Octobus driver for Nucleus has been corrected. Previously, this led to error code 1010148 from Nucleus, and made SIBAS fail giving error code -917. |
| - | An error in NK send is corrected. Previously, this led to error code 21328 (Lock timeout). |
| - | An error in the handling of the ND-100 FIFO queue has been corrected. This previously led to overwriting of the CPU data field, which was fatal when configuring a system with less than 35 ND-5000 processes (SINTRAN III Configuration Program). |
Page 19¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
Backup Manager for ND-500/5000 (211226B05)¶
All known errors in previous revisions are corrected:
| Report no. | Title |
|---|---|
| 22 | During Database backup, only the R-log file(s) is (are) copied and not the database itself. |
| 23 | Scheduled entry (BM-Scheduler) is not executed, but entry is deleted/updated (if periodic) in scheduler queue. |
| 25 | Missing SETs when listed (BACKUP/LIST and RESTORE/LIST) |
| 26 | Objects not found when listing or restoring from volume. |
| 27 | Various problems if more than 5 files of type 'IMAGE-NO-COMPARE' are defined in the BM-PARAMETER file. The maximum number of files of type 'IMAGE-NO-COMPARE' is increased to 12. |
SIBAS/R (220001B07)¶
All known errors in previous revisions are corrected:
| Report no. | Title |
|---|---|
| 20 | Error in the SIBAS call RELDV (-2), release all SIBAS connections and communication resources. |
| 52 | Error in accessing remote databases. |
| 54 | From SIBAS-Service or new applications, the SIBAS process seems to be in the passive state. |
| 55 | Avoid SIBAS-Service to store context in the User Environment database. |
| 57 | Error in SIBAS call SUEND with rollback. |
| 58 | OS-files defined with DIRECTORY:USER or :USER was not handled correctly. |
Page 20¶
Product Information¶
Comma¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
SIBAS Manager (211455A06)¶
| Report no. | Title |
|---|---|
| 2 | Error when running Consistency check (batch) on a renamed database user and directory. |
SPRINT Spooling System (211056A07)¶
| Report no. | Title |
|---|---|
| - | The first printers in the SPRINT table did not start properly. |
| - | Queue entries in SPRINT had to be 'forced' out one by one. |
Occasionally, print jobs could be printed on the wrong printer.
When more than 56 local and/or OpenLAN printers are defined, the error message 'No more free service ports available' sometimes occurred at SPRINT start-up.
Other hints:¶
If a printer gives an error message in SPRINT, you should check the printer itself before you stop and start the printer in SPRINT. Unnecessary restarting of printers will jam SPRINT, and you may end up with the message 'Sprint is busy'.
If the error device does not work, you will also get 'Sprint is busy'.
Page 21¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
5 Errors Known but Not Corrected¶
SIBAS/R (220001B07)
| Report no. | Title |
|---|---|
| 2 | Index tables destroyed in transactions. |
| 3 | Trace information is uninitialized in scheduler. |
| 4 | Error in disk cache |
Corrections to these errors are available as patches.
SPRINT Printer Drivers¶
| Report no. | Title |
|---|---|
| Version A07 of the SPRINT Printer Drivers (delivered with version C of the platform only) occasionally gives one of the error messages 'Outside segment bounds' or 'Argument Invalid' after the first printout on OpenLAN Printers. This is avoided by inserting the protocol name (e.g.: port=telnet) after the printer name in the AIP-HOSTS:SYMB file. Then restart SPRINT. For example: 130.067.006.132 printer name port=telnet |
Page 22¶
Comma¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
6 Modifications¶
This platform upgrade includes new versions of some of the products.
This section describes the major changes, if any, in the products.
ND-5830/5850 Microprogram¶
A separate Octobus driver is introduced in Nucleus to avoid the error code 2132₈ (Lock timeout).
Two new instructions have been implemented: - CLEDTSB (clear entry data TSB) - PCEDTSB (clear entry program TSB)
NOTIS-DS Version E04 (The Program DS-DOCREC)¶
The program DS-DOCREC, which is used to restore single documents from a tape backup of a NOTIS-DS database, is included.
User Environment Revision E00¶
The new version of the UE-RUN program (revision E01) has been adjusted for ADI (Application Development Interface).
Page 23¶
Special Modification Patches¶
Special Modification patches may now be installed while SINTRAN is running.
The installation is done as follows:
-
Edit the file
(SYSTEM)PF-MODIF-N:FADMso it contains the number(s) of the patch(es) you want to install (for example PN032). Ensure that the file is in 7-bit format. -
Run the program
(SPEC-MODIF-PATCH)SM-PATCHfrom user SYSTEM. This program will install the right patches in SINTRAN save area. During the installation you may get a warning, telling you that the patch is already installed, and a question if you want to reinstall the patch. Normally, you answer No to that question. An exception is when you are going to install a new version of a patch. -
Run a cold start to get the patches into effect.
-
The files
(SYSTEM)SM-PATCH-FILE:OUTand(SYSTEM)SM-PATCHES:OUTare the output files from the SM-PATCH program. Inspect them if something goes wrong during the installation.
| Product Name | Product Number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
Page 24¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 382300C01 |
8 General Information¶
Backup Manager Revision B05¶
The following limitation applies:
It is not possible to perform an IMAGE copy to or from a remote system.
SIBAS/R Revision B07¶
Additions/corrections to the documentation:
DIALOGUE Operations (830072.3):¶
Definition of the SQL Server:
Two new SW-CONFIG commands have been implemented to tune the performance of the SQL server. These are commands to the SQL server and must be placed in the section "SYSTEM-NAME : SQL-SERVER" in the SW-CONFIG file (refer to chapter 5.6.4 "The configuration file" in the manual).
- SYSTEM-NAME : SQL-SERVER-
- SQL-THREADS =
- SQL-PRIORITY =
<SIBAS server no.> : SIBAS process number (without leading zero).
<NThreads> : Number of SQL threads in use (1-4).
One (1) thread gives a single-thread SQL server (default).
<NRecords> : Number of records the SQL server can access before it gives up its priority and SIBAS can start another thread (default = 100 records).
Page 25¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to C02 | 38230C01 |
Work Space for the SQL Server¶
The work area (SINTRAN user area) for the SQL server must be defined in the SW-CONFIG file under the section "SYSTEM-NAME : SQL-SERVER-xxx".
DATA-FILE = (user name) file name
"file name" is used by the SQL server to generate names of the work files.
"file name" is only a prefix to the file names created by the SQL server and can be up to 13 characters long.
File type may not be given.
The SQL server will create (no. of threads * 5 + 3) work files on the SINTRAN user area defined. All files are created when the SQL server is starting, if they do not already exist. If the files already exist, all allocated file space will be released (it is quite safe to delete all the work files of a passive server).
The necessary work space on the SINTRAN user area depends on the following parameters: what kind of SQL queries to be run; the size of the returned data; if the data must be sorted; the number of active cursors; if "joins" are used; and the number of SQL threads in use (a set of work files is created for each thread).
The only way of finding the necessary work space is therefore to allocate a large amount of extra space and later release the unused space when the system has been in operation for a while (for example 5000–10000 pages).
DIALOGUE-SIBAS/R Application Development (DML) (860290.2)¶
Release Process Number, RELDV¶
The SIBAS call RELDV now has a new code for "ProcessNo":
- ProcessNo = -2
means all connections for all processes will be disconnected and all communication resources released. (ProcessNo = -1 will not release all communication resources).
If you use a program to access databases on more than one remote computer using TCP/IP communication, the program should do a RELDV(xx) on all process numbers used before terminating. A call to RELDV(-2,status) will release all resources for all process numbers.
Page 26¶
Product Information¶
| Product Name | Product Number |
|---|---|
| ND tpServer Platform Upgrade version CO1 to CO2 | 382300C01 |
Transaction Begin, STUBG:¶
The SIBAS call STUBG now has two new OptionCodes:
- OptionCode = 4
- Means that the tables listed in 'TableNames' are reserved for exclusive update for the user identified by 'UserID', until SUEND is called.
- Other users may read from these tables concurrently.
- The user identified by 'UserID' may also read from all tables not listed in 'TableNames'.
- OptionCode = 5
- Same as for 4 above, but other users are not allowed to read from the tables.
Added Function:¶
SIBAS/R B07 and QBE Vision:¶
To be able to use the new revision of QBE Vision (revision 2.06) to access a SIBAS database, using TCP/IP communication, SIBAS/R revision B07 has been modified to do "UE-login check" for QBE Vision.
This implies that a user does not need to log in to User Environment on a SINTRAN system, but QBE vision will ask for the User Environment username and password and send it to the SQL Server (part of SIBAS/R revision B07). The SQL Server will perform the UE-login check in the server system.
This means that all users of QBE Vision must have a User Environment user on the server.
The SIBAS process (SQL Server) in revision B07 has been modified to be able to log in as User Environment user SERVERS, and a new limitation has been introduced:
- The Database Administrator, which is defined in the file SW-CONFIG, must be created as user category Operator/Supervisor to be able to start a SIBAS process.
The handling of User Environment login is not default in the SIBAS process and must be specified in the file (SIBR-B)SIBRC-B07:DUMP. The procedure for activating User Environment login is described at the end of this file.
Note: Remember to set all the SIBAS processes in the passive state before the MODE file (SIBR-B)SIBRC-B07:DUMP is started.
Page 27¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version CO1 to CO2 | 382300C01 |
SPRINT OpenLAN Printers with SINTRAN Spooling Queue¶
The procedure for defining OpenLAN printers with a SINTRAN spooling queue is as follows:
-
Select a SINTRAN logical device number between 2300₈ and 2377₈ (1216 to 1279 decimal).
-
Connect the logical device number to the COSPO data field:
- Read the file SYMBOL-2-LIST:SYMB into an editor (for example PED) and find the symbol
F1731. Note the value of the symbol. - In a standard ND tpServer platform version C02 the value (data field address) is 077536.
Note:
This address may be different in later version. You should therefore always verify the value of this address, because patching in the wrong address may cause serious damage to your system. - Read the file SYMBOL-2-LIST:SYMB into an editor (for example PED) and find the symbol
-
Then execute the following commands:
@SINTRAN-SERVICE INSERT-IN-LOGICAL-UNIT-TABLE LOGICAL UNIT NUMBER (OCT): 23xx (use the device number you selected) INPUT OR OUTPUT? OUT DATAFIELD ADDRESS (OCT): 077536 (use the address you noted above) MEMORY? YES IMAGE? YES SAVE-AREA? YES EXIT -
Define the device number in the S3-CONFIG program and then perform a cold start or use the command
SET-SPOOLING-DEVICEin the SINTRAN Service Program. -
Define a peripheral file and spooling files in the usual way.
-
Stop COSMOS spooling by executing the command
@ABORT COSPO
(Otherwise you will get the error messageDevice already definedwhen defining the printer in SPRINT). -
Define the printer in AIP-HOST:SYMB and SPRINT.
-
Start COSMOS spooling:
@START-SPOOLING COSMOS-SPOOLING -
Stop and start SPRINT.
Otherwise you will get the error messageNot opened for sequential readwhen printing via SINTRAN III.
If the printer is only to be used from NOTIS-WP version N or later or other applications with a direct SPRINT interface, you should skip all steps above except 7 and 9.
Page 28¶
UPS Server for SINTRAN Version A¶
The server RT-program PFTCON will be started during a SINTRAN start-up, when running SINTRAN version N or later. The RT-program is an integrated part of SINTRAN N.
The PFTCON server will check if the UPS Power Supply is present by sending Octobus messages to the Octobus station of the UPS power supply. If no answer is returned from the UPS then the UPS power-server PFTCON will enter the passive state, otherwise it will reserve a TAD logical device and start the communication with the UPS Octobus station.
If a power is lost for more than ten seconds, the UPS power server will detect this, and the TAD device already reserved will execute the command:
MODE SHUT-POWERFAIL:MODE SHUT-POWERFAIL:OUT
When the mode file is finished, the UPS power server will take over and send an Octobus message to the UPS power to turn off the power to avoid battery drainage.
The SHUT-POWERFAIL:MODE is included in the platform software. For a non-platform system, this mode file should be modified according to the customer needs.
Note:
The files must not be deleted nor renamed!
A monitor program for display and adjustments can be used with the UPS Power Server. This program is called PS-MONITOR, and it uses Nucleus for communication with the power supply (requires that the command @START-SERVERS has been executed, and that your system is an ND-5000).
| Product Name | Product Number |
|---|---|
| ND tpServer Platform Upgrade version CO1 to CO2 | 382300C01 |
Scanned by Jonny Oddene for Sintran Data © 2022
Page 28 of 35 – Product Information
Page 29¶
Product Information¶
Product Name¶
ND tpServer Platform Upgrade version C01 to C02
Product Number¶
382300C01
9 Files Replaced by this Patch Kit¶
SINTRAN III/VSX-500 Standard System C (250306N01)
The file(s) have to be copied to user area SYSTEM:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| * COLD-START-SEQ:MODE | 3 | R | R | RWACD |
| * SHORT-HENT:MODE | 3 | R | R | RWACD |
| * BEFORE-COPY:MODE | 23 | R | RWA | RWACD |
| * BM-OPERATOR-B05:DOM | 673 | R | RWA | RWACD |
| * BM-OPERAT-XX-B05:SEG | 156 | R | RWA | RWACD |
| LIST-IMPLEMENTED:PROG | 12 | R | R | RWACD |
| RAM-SCRATCH:MODE | 1 | R | RWA | RWACD |
| + REMOVE-FILES:MODE | 2 | R | R | RWACD |
| PATCH-VERSION:MODE | 1 | R | R | RWACD |
| AFTER-COPY:MODE | 2 | R | RWA | RWACD |
| SW-VERSION:INFO | 2 | R | RWA | RWACD |
| * READ-SEGMENT:MODE | .2 | R | RWA | RWACD |
| SWAPPER-M05:PSEG | 33 | R | R | RWACD |
| SWAPPER-M05:DSEG | 51 | R | R | RWACD |
| FILSYS-SYMBOLS:SYMB | 31 | N | RWACD | RWACD |
| RTLO-SYMBOLS:SYMB | 28 | N | RWACD | RWACD |
| XMSG-SYMBOL-LIST:SYMB | 18 | N | RWACD | RWACD |
| N500-SYMBOLS:SYMB | 61 | N | RWACD | RWACD |
| ER-S3WD-DESC-D24:EDAT | 42 | N | RWACD | RWACD |
| ER-S3WD-LOG-D:PROG | 43 | N | RWACD | RWACD |
| ER-S3WD-MANA-D:PROG | 13 | N | RWACD | RWACD |
| SYMBOL-1-LIST:SYMB | 52 | N | RWACD | RWACD |
| SYMBOL-2-LIST:SYMB | 35 | N | RWACD | RWACD |
| LIBRARY-MARKS:SYMB | 8 | N | RWACD | RWACD |
| SINTRAN:DATA | 63 | N | N | RWACD |
| MACM-AREA:DATA | 64 | N | N | RWACD |
| PATCHES:OUT | 7 | N | RWACD | |
| PATCH-FILE:OUT | 7 | N | RWACD | RWACD |
| SHUT-POWERFAIL:MODE | 2 | R | RWA | RWACD |
| KERMIT:DOM | 107 | R | RWA | RWACD |
| SHUT-POWERFAIL:OUT | 0 | R | RWA | RWACD |
Files marked with an asterisk (*) will be deleted after installation.
Files marked with a plus sign (+) must be deleted manually with the command @DELETE-FILE.
Page 30¶
Product Information¶
ND tpServer Platform Upgrade version C01 to C02¶
Product number: 382300C01
SIBAS/R Version B (220001B07)¶
The file(s) have to be copied to user area SIBR-B:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| SM-SERVER-A062:DOM | 288 | R | RWACD | RWACD |
| SIBRP-B07:DOM | 2 | R | RWACD | RWACD |
| SIBR-LIBRARY-B07:ENTR | 10 | R | RWACD | RWACD |
| SIBR-FAST-B07:SEG | 133 | R | RWACD | RWACD |
| SIBLIB-B07:IMPT | 17 | R | RWACD | RWACD |
| SIBR-LIB-1B-B07:BRF | 31 | R | RWACD | RWACD |
| SIBR-LIB-2B-B07:BRF | 31 | R | RWACD | RWACD |
| SIBR-LIB-N-B07:NRF | 440 | R | RWACD | RWACD |
| SW-CONFIG:SYMB | 23 | R | RWACD | RWACD |
| SIBRC-B07:OUT | 0 | R/WACD | RWACD | RWACD |
| SIBRC-B07:ENTR | 3 | R | RWACD | RWACD |
| SIBRC-B07:PROG | 112 | R | RWACD | RWACD |
| SIBRC-UTIL-B07:PROG | 52 | R | RWACD | RWACD |
| SIBRC-B07:DUMP | 1 | R | RWACD | RWACD |
| SIBCOM-MONIT-B07:DOM | 95 | R | RWACD | RWACD |
| SIBR-MNT-EN-B07:ERR | 9 | R | RWACD | RWACD |
| SIBR-M-SERV-B07:PROG | 74 | R | RWACD | RWACD |
| SIBR-LIBRARY-B07:SEG | 98 | R | RWACD | RWACD |
| SIBR-INTER-B07:DOM | 178 | R | RWACD | RWACD |
| NEW-USER-104:PROG | 71 | R | RWACD | RWACD |
| JEC-B00:PROG | 43 | R | RWACD | RWACD |
| SIBLIB-MSG-GEN:DOM | 49 | R . | RWACD | RWACD |
| SIBAS:DUMP | 0 | R/WACD | RWACD | RWACD |
| CREATE-SERVERS:MODE | 1 | R | RWACD | RWACD |
| SIBR-DBM-OUT:DUMP | 0 | R/WACD | RWACD | RWACD |
| SIBRP-B07:SEG | 355 | R | RWACD | RWACD |
| SIBRP-USTAB-B07:SEG | 3 | R | RWACD | RWACD |
| SIBRP-COMMON-B07:SEG | 17 | R | RWACD | RWACD |
| SIBRP-500-B07:ENTR | 25 | R | RWACD | RWACD |
| SIBRP-CURBL-B07:SEG | 3 | R | RWACD | RWACD |
| SIBRP-DUMMY-B07:SEG | 3 | R | RWACD | RWACD |
| SIBRP-IOBUF-B07:SEG | 3 | R | RWACD | RWACD |
| SIBRP-SIFT-C:SEG | 4 | R | RWACD | RWACD |
| SIBR-DBM-COM-B07:SEG | 9 | R | RWACD | RWACD |
| SIBRP-NUCL:NRF | 3 | R | RWACD | RWACD |
| SIBR-DBM-B07:DOM | 665 | R | RWACD | RWACD |
| SIBRS-B07:ENTR | 6 | R | RWACD | RWACD |
| SIBR-DRL-COM-B07:SEG | 8 | R | RWACD | RWACD |
| SIBR-DRL-B07:DOM | 258 | R | RWACD | RWACD |
| SIBR-DBM-SYN-B07:OBJ | 37 | R | RWACD | RWACD |
| SIBR-DBM-B07:ENTR | 35 | R | RWACD | RWACD |
| DRL-SORTAB-B07:DOM | 15 | R | RWACD | RWACD |
| SIBR-SERVICE-B07:ENTR | 18 | R | RWACD | RWACD |
| SIBR-DBC-B07:SEG | 8 | R | RWACD | RWACD |
Page 31¶
Product Information¶
Product Name
ND tpServer, Platform Upgrade version CO1 to CO2
Product Number
382300C01
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| SIBR-FAST-B07:DOM | 17 | R | RWACD | RWACD |
| SIBR-DRL-B07:ENTR | 21 | R | RWACD | RWACD |
| SIBR-LOOKLOG-B07:PROG | 71 | R | RWACD | RWACD |
| SIBR-DPA-B07:PROG | 44 | R | RWACD | RWACD |
| SIBR-DBC-B07:DOM | 138 | R | RWACD | RWACD |
| SIBR-SERVICE-B07:DOM | 262 | R | RWACD | RWACD |
| SIBR-DBC-A07:PROG | 113 | R | RWACD | RWACD |
| SIBR-SQL-B07:SEG | 671 | R | RWACD | RWACD |
| SIBR-DEBUG-00:SYMB | 2 | R | RWACD | RWACD |
| SIBR-B07:PROG | 86 | R | RWACD | RWACD |
| SIBCOM-START-B07:MODE | 1 | R | RWACD | RWACD |
| SIBCOM-LOAD-B07:MODE | 1 | R | RWACD | RWACD |
| SEXMC-LOAD:MODE | 1 | R | RWACD | RWACD |
| SIBRS-B07:DOM | 96 | R | RWACD | RWACD |
| SM-TRMH-A06:DOM | 36 | R | R | RWACD |
| UPS-DBSTOP:DOM | 36 | N | RWACD | RWACD |
NOTIS-DS for ND-500/5000 Version E (210794E04)¶
The file(s) have to be copied to user area OPENLAN:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| DUMMY-DS-LIB-F:SEG | 271 | R | RWA | RWACD |
| DSOWS-LIBRARY-F:SEG | 486 | R | RWA | RWACD |
UPS Server Version A (212036A02)¶
The file(s) have to be copied to user area TEST-USER:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| PS-MONITOR:PROG | 80 | R | R | RWACD |
Page 32¶
Product Information¶
Product name: ND tpServer Platform Upgrade version C01 to C02
Product number: 382300C01
User Environment Version E (210518E00)¶
The file(s) have to be copied to user area USER-ENVIRONMENT:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| UE-RUN-E01:PROG | 127 | R | RWAC | RWACD |
| UE-500-E00:DOM | 337 | R | RWAC | RWACD |
| UE-PMAN-DA-E00:NDPF | 39 | R | RWAC | RWACD |
| UE-PMAN-DA-E00:CONF | 32 | R | RWAC | RWACD |
Every terminal using the menu system uses one System LAMU.
Special Modification Patches¶
The file(s) have to be copied to user area SPEC-MODIF-PATCH:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| SM-PATCHES-2200:SEL | 4 | R | R | RWACD |
| SM-SYMBOLS-2200:FADM | 1 | R | R | RWACD |
| SM-REFEREN-2200:FADM | 1 | R | R | RWACD |
| SM-PATCHES-2200:PATC | 8 | R | R | RWACD |
| SM-PATCH:PROG | 21 | R | R | RWACD |
| SM-START-PA-FILE:MODE | 1 | R | RWACD | RWACD |
| SM-PATCH-FILE:MODE | 3 | R | RWA | RWACD |
| SM-PF-LIBR-2200:FADM | 1 | R | R | RWACD |
OWS Access Server for ND-5000 Version B (211325B04)¶
The file(s) have to be copied to user area OPENLAN:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| OWSSPOOL5-C01:PROG | 47 | R | RWA | RWACD |
| OWSRT5-C01:PROG | 21 | R | RWA | RWACD |
| OWSAS-SERVI5-C01:PROG | 41 | R | RWA | RWACD |
| OWS-DISTIME5-C01:PROG | 10 | R | RWA | RWACD |
| OWSACCSERV-C01:DOM | 132 | R | RWA | RWACD |
896058 EN 4
Scanned by Jonny Oddene for Sintran Data © 2022
Page 33¶
Product Information¶
| Product name | Product number |
|---|---|
| ND tpServer Platform Upgrade version C01 to CO2 | 382300C01 |
SPRINT Spooling System Version A (211056A07)¶
The file(s) have to be copied to user area SPRINT-USER:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| SSY-SERVER-A07:PROG | 112 | R | RWA | RWACD |
Note: Do NOT restart a printer from SPRINT (without investigating first). If a printer gives an error message in SPRINT, check the printer itself. If no reason for the problem is evident, you may restart the printer.
Unnecessary starting of printers will 'jam' SPRINT, and you may end up with the message 'Sprint is busy'.
Note that OpenLAN printers may sometimes give 'misleading' error messages. If a printer stops due to paper crash or empty input bin during a printout, the connection will stay open and give one of the messages 'Printer is occupied. Waiting for access' or 'Impossible to send data to printer' when printing from another system. These messages may then also mean paper crash if they do not disappear within reasonable time.
Always check the printer itself before you do anything else.
Backup Manager for ND-500/5000 Version B (211226B05)¶
The file(s) have to be copied to user area BACKUP-MANAGER:
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| BM-OPERATOR-B05:DOM | 702 | R | RWACD | RWACD |
| BM-FILERESTO-B05:DOM | 517 | R | RWACD | RWACD |
| BM-SCHEDULER-B05:DOM | 177 | R | RWACD | RWACD |
| BM-DEFINITO-B05:DOM | 342 | R | RWACD | RWACD |
| BM-SERVER-B05:MODE | 1 | N | RWACD | RWACD |
| BM-DUMP-B05:MODE | 1 | N | RWACD | RWACD |
| BM-START-B05:MODE | 1 | N | RWACD | RWACD |
| BM-SERVER-B05:PROG | 105 | N | RWACD | RWACD |
| BM-DEFINI-XX-B05:SEG | 108 | R | RWACD | RWACD |
| BM-OPERAT-XX-B05:SEG | 156 | R | RWACD | RWACD |
| BM-FILERE-XX-B05:SEG | 68 | R | RWACD | RWACD |
| BM-SCHED-XX-B05:SEG | 108 | R | RWACD | RWACD |
896058 EN 4
Scanned by Jonny Odden for Sintran Data © 2022
Page 34¶
Product Information¶
Product name
ND tpServer Platform Upgrade version C01 to C02
Product number
382300C01
Microprograms¶
Microprogram for ND-5830/5850 version B (211847B01)
- ND-5800 Microprogram (211276F01)
- ND-5700 Microprogram (211275F01)
- ND-5500 Microprogram (211274E03)
- ND-5400 Microprogram (211273E03)
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| MICRO-5800-B34:DATA | 128 | R | R | RWACD |
| MICRO-5700-B34:DATA | 128 | R | R | RWACD |
| MICRO-5500-B34:DATA | 128 | R | N | RWACD |
| MICRO-5400-B34:DATA | 128 | R | N | RWACD |
| MICRO-5850-12012:DATA | 144 | N | RWAC | RWACD |
| MICRO-5830-12012:DATA | 144 | R | RWA | RWACD |
One of these files must be copied to the file (SYSTEM)CONTROL-STORE:DATA.
Multi-Machine Operator Environment (211078A01)¶
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| OEM-SERVE-A03:PROG | 106 | N | RWACD | RWACD |
| CHANGE-DOM:PROG | 27 | R | RWACD | RWACD |
TCP/IP Basic Module III Version D (211327D01)¶
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| TCP-BA-LOAD-D01:MODE | 1 | N | RWACD | RWACD |
Page 35¶
Product Information¶
Product Name¶
ND tpServer Platform Upgrade version C01 to C02
Product Number¶
382300C01
SINTRAN III Version N, Revision 2200 (250306N01 + 250360N01)¶
The file(s) have to be copied to user area RT:¶
| File name | File size | Public access | Friend access | Own access |
|---|---|---|---|---|
| S3SFSSGMENT:BPUN | 54 | R | R | RWACD |
| S3SCPSGMENT:BPUN | 54 | R | R | RWACD |
| S3SRPITSGEMENT:BPUN | 52 | R | R | RWACD |
| S3SMPITSGEMENT:BPUN | 52 | R | R | RWACD |
| S3SSGTSGEMENT:BPUN | 17 | R | R | RWACD |
| S3SSPDSGEMENT:BPUN | 2 | R | R | RWACD |
| S3SJPIITSGEMENT:BPUN | 6 | R | R | RWACD |
| S3SDPITSGEMENT:BPUN | 46 | R | R | RWACD |
| S3SYSSGEMENT:BPUN | 4 | R | R | RWACD |
| S3SECOMSGEMENT:BPUN | 3 | R | R | RWACD |
| S3SMSFSGEMENT:BPUN | 49 | R | R | RWACD |
| S3SIPITSGEMENT:BPUN | 52 | R | R | RWACD |
| S3SSMSGEMENT:BPUN | 37 | R | R | RWACD |
| S3SDMSDSGEMENT:BPUN | 5 | R | R | RWACD |
| S3SXWKESGEMENT:BPUN | 32 | R | R | RWACD |
| S3SXROUSGEMENT:BPUN | 34 | R | R | RWACD |
| S3SDNAMESGEMENT:BPUN | 7 | R | R | RWACD |
| S3SXMFIISGEMENT:BPUN | 55 | R | R | RWACD |
| S3SNKSESGEMENT:BPUN | 53 | R | R | RWACD |
| S3SNKASESGEMENT:BPUN | 65 | R | R | RWACD |
| S3SUI1OSEGMENT:BPUN | 33 | R | R | RWACD |
| S3SUI2OSEGMENT:BPUN | 33 | R | R | RWACD |
| S3SERWCSGEMENT:BPUN | 53 | R | R | RWACD |
| S3SERWDSGEMENT:BPUN | 57 | R | R | RWACD |
| S3SPRMASEGMENT:BPUN | 53 | R | R | RWACD |
| S3SPWRSSGEMENT:BPUN | 53 | R | R | RWACD |
| S3SBOPCSEGMENT:BPUN | 53 | R | R | RWACD |
| S3SMTSESGEMENT:BPUN | 5 | R | R | RWACD |
These files will be deleted after installation.