Page 1¶
Product Information¶
Product name
UNIQUE UNIQUICK SIBAS for ND-110
Product number
210871C
Description of Product¶
Easy, interactive application generator for UNIQUE-II SIBAS.
Reason(s) for New Product or Version¶
Revision C13. Error correction and some modifications.
Revision C14. Error correction.
Minor significant changes in this PI-sheet are marked with '**'.
Table of Contents¶
| Topic | Page |
|---|---|
| Prerequisites | 2 |
| Dependencies | 3 |
| Documentation | 4 |
| Installation procedure | 5 |
| Modifications | 8 |
| Errors corrected | 10 |
| Errors known but not corrected | 10 |
ND-895184.1B EN
[Scanned by Jonny Oddene for Sintran Data © 2011]
Page 2¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.02.09 | 2 of 10 |
| Product name | Product number |
|---|---|
| UNIQUE UNIQUICK SIBAS for ND-110 | 210871C |
1 Prerequisites¶
The following things are required in order to use this product.
1.1 Hardware Prerequisites¶
The following hardware must be present for this product to be used:
CPU type (any of the following):
- 100 Standard
- 100 CX
- 110 Standard
- 110 CX
- 120 Standard
- 120 CX
- Butterfly Teamstation
Floating format: 32/48
1.2 Software Prerequisites¶
The following software must be installed on the system for this product to be used:
Operating system:
| Name | Version/Revision |
|---|---|
| SINTRAN-III VSE/VSX | >= I |
Other software:
| Product name | Product number |
|---|---|
| SIBAS-II | 210166F |
| Software keys | 210507B |
| or UNIQUE Software Key | |
| UNIQUE Text System, version >= C10 | 211005C |
| BRF-LINKER, version >= B (but not C00) | 210721B |
| UE-PLIB, version >= C03*, included in: | 210518C |
| NOTIS-WP (or another editor) | 210079M/N* |
Note: UNIQUE SIBAS for ND-110 cannot be used together with SIBAS/R version, since there is not enough room on the program segments to load this SIBAS library.
ND-895184.1B EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 3¶
Product Information¶
Date: 90.02.09
Norsk Data
Page 3 of 10
Product name
UNIQUE UNIQUICK SIBAS for ND-110
Product number
210871C
1.3 Other Prerequisites¶
The following are necessary for this product to be used.
Minimum Permanent Mass Storage:
| User | Space (pages) | Number of files |
|---|---|---|
| DIALOG-SYS | 70 | 1 |
| 300 | 10 |
| Minimum | Maximum | |
|---|---|---|
| Number of segments (ND-100) | 2 | 3 |
Space required on segment files: 230 pages
Requirements regarding internal devices:
None
Requirements regarding batch processors:
None
2 Dependencies¶
In addition to the above listed hardware and/or software prerequisites, the following dependencies exist between this and other products. The hardware and software listed here may, for example, be necessary to use the product’s full functionality.
2.1 Hardware Dependencies¶
None
ND-895184.1B EN
Scanned by Jonny Oddene for Sintran Data © 2011
Page 4¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.02.09 | 4 of 10 |
| Product name | Product number |
|---|---|
| UNIQUE UNIQUICK SIBAS for ND-110 | 210871C |
2.2 Software Dependencies¶
| Product name | Product number |
|---|---|
| Unique-II SIBAS for ND-110 | 210729C |
Nature of dependency
Revision C10 or later must be installed to be able to compile and run the applications generated with UNIQUICK.
| Product name | Product number |
|---|---|
| User Environment | 210518 |
Nature of dependency
When User Environment is active, version C03* or later is required.
| Product name | Product number |
|---|---|
| NOTIS-WP | 210079M/N |
Nature of dependency
When using NOTIS-WP for editing UNIQUE-II applications, version M or later is required. When using version N or later, please see chapter 5.4, Other Modifications.
3 Documentation¶
Included (distributed free with product)
| Title | Number |
|---|---|
| DIALOGUE UNIQUICK User Guide | ND-860240.2 EN |
| DIALOGUE UNIQUICK Brukerveiledning | ND-860240.2 NO |
ND-895184.1B EN
Page 5¶
Product Information¶
| Date | 90.02.09 |
|---|---|
| Norsk Data | Page 5 of 10 |
Product Name¶
UNIQUE UNIQUICK SIBAS for ND-110
Product Number¶
210871C
4 Installation Procedure¶
4.1 Automatic Installation¶
4.1.1 Preparations¶
Prior to the installation, verify the following:
- Ensure that the user areas specified in Chapter 1.3 exist with the required number of free pages and free files. If not, find a directory having enough space to hold the user areas. The installation program will try to allocate space whenever needed, but you may need to specify on which directory to create user areas.
- The following files will be loaded with UNIQUICK:
| Abbrev. | File Name | Default User Area(s) |
|---|---|---|
| SIBAS libary | SIB-LIB | SIB-500 |
| UE library | UE-PLIB | USER-ENVIRONMENT |
Check where these files are installed. If not installed on the default user area, the installation program will ask where to find these files.
- Ensure that your configuration fulfills all other requirements mentioned in Chapter 1 and 2.
4.1.2 Installation from Floppy¶
- Put the diskette 210871C
-XX-01D into the floppy drive. - Log in to user area SYSTEM.
- Enter directory 210871C-XX-01D.
- Run the INSTALL program on the diskette.
Example: How to enter the directory and start the installation program (user input is underlined).
@ENTER-DIRECTORY 210871C-XX-01D FLOPPY-DISC-1 0↵
@(210871C:FLOPPY-USER)INSTALL↵
ND-895184.1B EN
Page 6¶
Product Information¶
| Date | Page |
|---|---|
| 90.02.09 | 6 of 10 |
| Norsk Data |
|---|
| PRODUCT INFORMATION |
| Product Name | Product Number |
|---|---|
| UNIQUE UNIQUICK SIBAS for ND-110 | 210871C |
The following screen will appear:
---------------------------------------------
| |
| I N S T A L L A T I O N |
| U N I Q U I C K S I B A S |
| N D 1 0 0 V E R S I O N C x x |
| |
| Unique A/S Date: 24-JUN-88|
| |
| --> Initialising - please wait --> |
| --> Sintran version:K Revision:3100 |
| Generated:15-MAY-86 |
| --> Cpu number :456 |
| |
| You may ESCAPE at any time to abort the |
| installation procedure. |
| Choose one of the following options: |
| |
| 1 - CREATE : Create user and allocate space |
| 2 - COPY : Copy files from floppies |
| 3 - LOAD : Make and run load procedure |
| 4 - DUMP : Define system reentrant |
| 0 - EXIT : |
| |
| Make your selection (1/2/3/4/0): |
| |
----------------------------------------------
The installation program will ask you for information (user areas, directory names, etc.) but will usually suggest reasonable default values. You can answer these questions by typing ↵ (the ENTER key) thus using the default value.
You may install UNIQUICK on any user area, but DIALOG-SYS is used as default in the installation program.
The installation program can do the following:
- CREATE: Create a new user area (or verify an existing one) for UNIQUICK.
- COPY: Copy all files from the floppy to the desired user area.
- LOAD: Write the load procedure and load the UNIQUICK program files.
- DUMP: Dump UNIQUICK as a reentrant program.
- EXIT: Leave the installation program and return to SINTRAN.
The first time, run all the tasks 1-4, one at a time, in sequence. To reload UNIQUICK, run tasks 3 and 4. To re-dump UNIQUICK, run task 4.
When selecting the CREATE or COPY option, and an (old) version exists on this user area, you are asked if these files should be deleted.
ND-895184.1B EN
Page 7¶
Product Information¶
| Date 90.02.09 | Norsk Data |
| Page 7 of 10 |
| Product name | Product number |
|---|---|
| UNIQUE UNIQUICK SIBAS for ND-110 | 210871C |
You may answer Yes, No or Manually. When answering YES, program files, domain files, .MODE and .LIST files of current and previous versions/revisions will be deleted. Afterwards the program checks if there are enough free pages on the user area.
When selecting the LOAD option, there are some questions that need an explanation:
LANGUAGE: 'Language to be used if UE is not active? /NO/'
By default UNIQUICK will use the language found in the user profile in User Environment. The answer to this question selects the language to be used if UE is NOT active on the terminal running UNIQUICK.
SW-CONFIG: 'Should it be legal for users to define their own SW-CONFIG:SYMB file? /N/'
Answer Y if you want to allow users to have a personal copy of the configuration file.
After a successful installation of UNIQUICK, you must update the system startup file (HENT-MODE:MODE) with the following command:
@MODE (<user>)QUIC-DUMP-S1-C:MODE (<user>)QUIC-DUMP-S1-C:LIST
where
4.1.3 Subsequent Installation¶
If at a later date you want to reload or re-dump UNIQUICK, you can use the installation program that is automatically copied from the floppy during the first installation. To re-run the installation program, log in to user area SYSTEM and type:
@(DIALOG-SYS)QUICK-IN-S1-C-
To reload UNIQUICK, run tasks 3 and 4. To re-dump UNIQUICK, run task 4.
You may of course also reuse the previously created load/dump procedures (:MODE).
ND-895184.1B Eiw
Page 8¶
Product Information¶
| Product name | UNIQUE UNIQUICK SIBAS for ND-110 |
| Product number | 210871C |
4.2 Non-Automatic Installation¶
Create a user area with the number of pages mentioned before and copy all the :BRF and :MODE files from the floppy into it.
Log in to the user area containing the :BRF files. Edit the file QUIC-LOAD-S1-C:MODE to suit your configuration and run it by typing:
@MODE QUIC-LOAD-S1-C:MODE "QUIC-LOAD-S1-C:LIST"
Update the file QUIC-DUMP-S1-C:MODE in the same way and run it from user SYSTEM. Remember to update the system startup file (see also section 4.1.2).
5 Modifications¶
5.1 New Functions/Commands¶
Revision C10¶
- UNIQUICK has been rewritten with a new user interface and new application generating routines.
- Advanced applications can be made using many tables (owner-member structures and join structures) and most UNIQUE-II field functions are available.
- The word "Letter" (language dependant) is displayed in the status line if you have some unread electronic mail (NOTIS-ID).
- New terminology has been introduced in the DIALOGUE family. UNIQUICK uses the new terminology.
- UNIQUICK now reads the parameter
prefix-source=from the SW-CONFIG file, undersystem-name:<domain-name>orsystem-name:0.system name:0denotes parameters valid for all UNIQUE systems.
- There is an additional configuration parameter,
UNIQUE-ON-LINE=, which is not documented in the manual. This is used to tell UNIQUICK the name of UNIQUE-II if the standard name is not used.
ND-895184.1B EN
Page 9¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.02.09 | 9 of 10 |
| Product name | Product number |
|---|---|
| UNIQUE UNIQUICK SIBAS for ND-110 | 210871C |
Example of use:¶
SYSTEM-NAME: @
UNIQUE-ON-LINE : UNIQ-II-SIBAS
- If the file ()UNIQUICK-C-HEAD:INCL can be opened it is used to make a heading for the application. In addition, for each ^ character found, the application name is inserted.
Example of UNIQUICK-C-HEAD:INCL:
+-----------+
| Unique-II |
| ^ |
+-----------+
5.2 Changed Functions/Commands¶
Revision C13¶
- The question on whether to create a :UCOM file has been removed. UNIQUE-II handles :UCOM file creation automatically.
- The UNIQUE-II password tables are now only available if running from Sintran user area SYSTEM.
5.3 Removed Functions/Commands¶
None
5.4 Other Modifications¶
Revision C13¶
- Due to changes in the S-format required in different versions of the NOTIS products, a new file must be present on user DIALOG-SYS. This file is named UQ-ND-S:INI and must have public read access.
All S-format files produced by UNIQUE products will have the same S-format header as the file (DIALOG-SYS)UQ-ND-S:INI.
ND-895184.1B EN
Page 10¶
Product Information¶
| Date | Norsk Data | Page |
|---|---|---|
| 90.02.09 | Norsk Data | 10 of 10 |
Product Name¶
UNIQUE UNIQUICK SIBAS for ND-110
Product Number¶
210871C
UQ-ND-S:INI is an 'empty' file containing only an S-Format header matching the version of NOTIS-WP you are using on your machine. By storing the S-Format header in a file, it is possible for you to define the default settings and rulers. UNIQUE will read the default header from this user-defined file, if it exists.
If you start using a version of NOTIS-WP with a new S-Format, e.g. going from WP version M to N, just repeat the procedure described below and UNIQUE will produce documents readable by the new WP version.
You have to install/create this file manually:
1. Log in on user area DIALOG-SYS.
2. Start NOTIS-WP.
3. Use the internal menus in WP to set the wanted default values.
4. Make sure you define it to be an S-Format document.
5. Type some blanks so WP will store it as a document.
6. Save this 'empty' document to the file "UQ-ND-S:INI".
7. Set public access to READ: @set-file-access UQ-ND-S:INI R R,,,
6 Errors Corrected¶
The product diskette contains a list of the errors corrected in the current and previous revisions (filename QUICK-ERRLOG-
7 Errors Known But Not Corrected¶
Revision C13/C14
- The LEGAL-VALUES() function is written out before the KEY() function.
- Two joins from the same column will fail, only one will be included in the :UNIQ file.
ND-895184.1B EN