Skip to content

Page 1

ND 10195 Data Entry System II

INTRODUCTION

The ND Data Entry System II consists of a set of software modules offering a flexible and easy way of entering and validating data in an ND-100/SINTRAN III/VS computer system.

One big advantage of ND Data Entry System II is that it can provide extensive checking of input so that only proper data are accepted for further processing, avoiding unnecessary additional entering, dominating expensive error-correction procedures and the nuisance of inaccurate reports.

FEATURES

  • For multi-terminal heavyweight data entry.
  • Based on SIBAS and NSHS (ND Screen Handling System).
  • Advanced screen handling operations using asynchronous display terminals with cursor control.
  • Immediate reaction to errors both at the character entry level and at the data field entry level, such that when all data fields have been entered, they are correct as far as the system can judge. One does not wait until the screen is full before checking what has been typed in.
  • Built-in field editing of numeric, decimal, alphabetic, alphanumeric fields, bank account and social security number, various data formats.
  • Field control by content checking defined as a part of picture definition:
    • default value
    • check digit verification
    • data-controls
    • field accumulation
  • End-user oriented
    • Help function
    • Defaults provided
  • Easy corrections when altering field values, including copy of previous value, inserting or deleting characters, all by simple keystrokes.
  • Records may be deleted.
  • Duplicate function sets fields in a schema whose values are duplicated from transaction to transaction
    • remembers which fields
    • values set from session to session
    • new values can be given
  • Verification — checking for correct registration.
  • Routing — the definition of a path for the order in which the fields in a schema are to be input. Can be:
    • fixed
    • dynamic
    • overruled
    • this together with Duplicate gives a very useful skip and duplicate facility.
  • Searching for a registered transaction.
  • Total batch sums may be obtained for up to 5 fields within the same job.

PRODUCT DESCRIPTION

The ND Data Entry System II makes use of a SIBAS database to administer registered data. It consists of three subsystems:

  • DAD: Data Entry Administrator
  • DED: Data Entry Editor
  • DWF: Work File Handler

The Data Entry Administrator is used to define the operators, i.e., persons allowed to register and modify data in the Data Entry Editor and the jobs to be executed. A job is a sequence of data to be registered or modified. Schemas (screen pictures) are used for this registration. They are made by the aid of ND Screen Handling System (NSHS). DAD also maintains the names of schema files and system parameters.

The Data Entry Editor is used by the operator that actually keys in the required data.

The Data Entry Editor presents a picture of the required schema on a display terminal and allows the operator to fill in various fields from the original to the corresponding fields on the screen. The operator does not need to consider actual column positions, the editor automatically moves from one field to the next in any predefined order (see routing above), or can be positioned to a desired field by the operator.

Thus the operator may easily go back and modify any field that has been entered.

The registered data are stored in the data realm in the data base. They are accessible by way of the Data Work File Handler (DWF). In DWF data records may be inspected, printed, deleted or output to a SINTRAN file.

REFERENCES

Reference Description
ND 60.125 SINTRAN III INTRODUCTION
ND 60.050 SINTRAN III User's Guide
ND 60.132 SINTRAN III Time-Sharing/Batch Guide
ND 60.128 SINTRAN III Reference Manual
ND 60.088 The Nord Screen-Handling System
ND 60.127 The Data Base System SIBAS II User's Manual
ND 60.154 ND Multiuser Data Entry System

Page 2

      .o88o.               o8o               o8o                .o88o.               
       888 `"               `"'               `"'                888 `"              
      o888oo oooo   ooo.  oooo   .ooooo.   oooo   .ooooo.       o888oo  ooo. .oo.   
       888   `888   `888  `888  d88' `88b  `888  d88' `88b       888   `888P"Y88b  
       888    888    888   888  888ooo888   888  888ooo888       888    888   888  
       888    888    888   888  888    .o   888  888    .o       888    888   888  
      o888o  o888o  o888o o888o `Y8bod8P'  o888o `Y8bod8P'      o888o  o888o o888o 

Contact Information

City Address Telephone Telefax
Oslo Olav Helsets vei 5, Boks 5 Bogerud 02-995400 02-295617
Bergen 05-202590
Sandnes 04-665254
Tromsø 83-77766
Stockholm Box 610, 19000 lx, 15255 nordata s 08-706-09000
Gothenburg Tel. 031-497660
Malmø Tel. 040-75120
Copenhagen Gl. Kongeve j - Suoveits, 37265 nd dk
Wiesbaden Tel. 06124-761, 11x 41876370 noda n
Femy-Voltaire Tel. 063-407656, tk: 385653 nordata fermv
Paris Tel. 1-39793267, tex 301100 paris
Lyon Tel. 1-837 43117, tk 837 55981
Newbury Tel. 0635-316545, tk 83419 norsk g
Utrecht Tel. 03048-36743
Boston Tel. (617) 237-7945, tk. 921740 norsk welt

COMTEC Division of Norsk Data

Location Address Telephone Telefax
Trondheim Tel. 075-16520, tlx. 55580 comtec n
Stockholm Tel. 0760-84100, tlx. 15255 nordata s
Odense Tel. 09-517440, tk 59860 comtec dk
Düsseldorf Tel. 0211-666388, tk. 825727 comnt d
Jerikoveien 20 Boks 4 Linderbergård Oslo 10 Tel.: 02-99300
      ____  ____  _________    ____  _____
     /    \/    \/   \     \  /    \/     \
    /          /\            \/             \
    \       __/  _HOVING PLANT SYSTEM      |
    /      / \/      DES-GROUP97p           |
    \     / /        TEST EQUIPMENT         |
    /    /\/                                |
    \  _/ |\_____/                          |
     \/ \_|_                               |
       \___/                               /

NOTE: NORSK DATA reserves the right to change specifications without notice