Page 1¶
¼" Cartridge Streaming Tape Drive¶
ND 106270
[Photo: Tape drive image]
.---.
/ \
| |
| |
\ /
`---`
ND Norsk Data
[Scanned by Jonny Oddene for Sintran Data © 2021]
Page 2¶
1/4" Cartridge Streaming Tape Drive¶
INTRODUCTION¶
The ND 106270 is an 5 1/4" form factor, high-quality, cost-effective, cartridge streaming tape drive. Streaming is the technique of writing to and reading from a magnetic tape without making frequent stops. High capacity, compact size, and the ability to record data on industry standard 1/4" cartridge media are basic attributes of the ND 106270. Large scale integration (LSI) employed extensively in the ND 106270 electronics is designed to produce superior reliability.
FEATURES¶
- High-capacity/low-cost media.
- High data-transfer rate.
- Multifunction capability.
- Intelligent control.
- Standard interface (CIQ-02).
- Data integrity.
TRACKS
5
┌───────────┐
│ 1 │
│ ┌─────────┘
│ │ 7
│ └───────┐
│ │
└── 3 │
┌──────┘
│ 4
└─────┐
│
0 ─────┘
┌────────┐
│ 6 │
│ ┌──────┘
│ │ 2
│ └────┐
│ │
└──────┘
8
B.O.T. (PHYSICAL) E.O.T. (PHYSICAL)
E.O.M. (LOGICAL)
Nine-track recording
Serpentine Recording
Page 3¶
1/4" Cartridge Streaming Tape Drive¶
PRODUCT DESCRIPTION¶
- The ND 16072 Cartridge Streaming Tape Drives uses an ANSI Standard X3.55-1977 1/4" tape cartridge which is 600' or 450' long.
- The Read/Write head assembly consists of two Read and Write heads with an Erase bar for full tape erase prior to recording. This allows the tape unit to perform a read-after-write check during a Write operation.
- A 4 to 5 run-length limited code is used because every four bits of data are translated to a corresponding five-bit code. Using this code will prevent the recording of three consecutive zeros in the data stream, thus allowing for efficient NRZI recording onto the tape.
- The 4 to 5 code also permits unique bit patterns for GAP, SYNC, and FILEMARK, which will never appear in the users' data field.
TECHNICAL SPECIFICATIONS¶
| Data handling: | |
|---|---|
| Recording Track/Format | 9-track serpentine |
| No. of Channels | 2 |
| Formatted Capacity | Up to 60 MB |
| Backup Time | 12 min. (without compare) |
| Recording Mode | NRZI |
| Recording Density | 8000 BPI |
| Recording Code | (0,2) Run-Length Limited |
| Flux Density | 10,000 frpi |
| Track Capacity | Up to 6.5 MB |
| Data Transfer Rate | 86.7 Bytes/sec. |
| Tape Speed | 90 IPS |
| Start/Stop Time | 300 msec |
| Media | ANSI Standard X3.55-1977 certified for 10,000 frpi |
| Device Reliability: | |
|---|---|
| Recoverable Error Rate | No more than 1 in 10^8 bits |
| Non-recoverable Error Rate | No more than 1 in 10^10 bits |
Power Requirements for basic drive and formatter:¶
-
- 12 V ± 10 % 1.0A nom. 3.0A max.
-
- 5V ± 5 % 3.1A max.
- Typical Dissipation 21.5 Watts
Physical Dimensions for basic drive:¶
- Height 44 mm
- Width 150 mm
- Depth 218 mm
- Weight basic drive and formatter 1.9 kg
DOCUMENTATION:¶
Tandberg Reference Manual TDC 3319