Skip to content

Page 1

ND Computer Systems

ND810 Input Configuration

                     External
                    Equipment
                       |       
                       |       
                       |          
                       V         
                     +--+   
          Vi         |Dx|        
 ---------------->---|  |--------+              
             RE      |  |        |       
             Limiting+--+        |        
             Resistor            |        
               |                 |        
               |                 |        
               V                 V        
             +--+     VARISTOR  +-+       
             |Dx|<--------------|Z|       
             |  |     3.3V      +-+       
             |  |                                  
             +--+                  +----------+---+  
               |     Opto         |Opto Coupler|   
               +----|De|---------| HP 5082-4360|   
                       |          +----------+|     
                       |                       +---      
                       |                           |   
                       |------Dix0                 |   
                      5V                           | 
                                                   V     
                                          Computer Ground

ND811 Output Configuration

               5V                          
               |    
               +-----+-->
               |     |  From output latch      
           +---+----+---+   
           | Photo-    |   
           | Darlington| 
           | Relay     |   
         +-+  MCA2-55  +--+         I0    
         | +-----------+   |      +-----+    
         |                 |      |     |   
         V                 \      /     |
      +--+                  \680k /     |
      |D1|                   \   /      |
      +--+                    \_/-------+    Vc
         |         
         |                    RE
         |                 External
      +--+---+            Equipment         
      | D0   |
      +------+

ND810 Process Digital Input

ND811 Process Digital Output

Introduction

The ND810 and ND811 optically coupled digital input/output modules are designed for industrial and marine applications for interfacing ND computers to relays, lamps, and on/off contacts. Each module occupies one standard I/O slot.

Features

  • 12 bits in — 16 bits out
  • All lines optically coupled
  • Internal programmable Compare Register
  • Contact debounce logic
  • Input signal conditioning

Product Description

The ND810 Input Module contains a programmable 12-bit Compare Register. If the input data pattern and the Compare Register differ, an interrupt will be generated.

The ND811 Output Module does not generate any interrupts. 16 bits of data are simply loaded into a holding register and will immediately be available at the output terminals.

810/811–A3–1500–0681
Scanned by Jonny Oddene for Sintran Data © 2010

Page 2

SPECIFICATIONS

ND810 Input Module

  • Number of digital inputs: 12
  • Operating temperature: 0 - 55°C
  • Operating relative humidity: 0 - 90% no condensation

Electrical Characteristics

Min. Typ. Max.
VIT = Transition Voltage 5.5V
VIH = High level input voltage 7.8V
VIC = Low level input voltage 1.7V
IIH = High level input current, @VI = 12V 9.3mA
IIL = Low level input current, @VI = 1.5V 0.25mA
@VI = -15V -10mA

For VI > 12V, a limiting resistor — RE — must be included in external equipment.

Absolute Maximum Ratings

Voltage between corresponding input terminals: -15V, +13.5V.

NOTE: DXo, DX1
- D = Data
- X = Data bit #
- Index 0 = -terminal
- Index 1 = +terminal

Continuous Common Mode voltage between computer ground and input terminals: ± 30V.

Switching Characteristics

Delay from any change in input to interrupt: 4 ms ± 20%. A change in any input line must exceed the 4 ms in order to generate the interrupt. This constitutes the contact debounce logic.

ND811 Output Module

  • Number of digital outputs: 16
  • Operating temperature: 0 - 55°C
  • Operating relative humidity: 0 - 90% no condensation

Electrical Characteristics

Min. Typ. Max.
VOL = Low level output voltage, @IOL = 30mA 0.9V 1V
IOL = Low level output current 30mA 80mA
IOH = High level output current, @VOH = 30V 1µA

Absolute Maximum Ratings

  • Voltage at terminal DXi relative DXo: -5V, +30V.
  • Continuous common mode voltage between computer ground and output terminals DXo or DXi: ± 30V.
  • Maximum continuous output current: 100 mA. Inductive load should be properly bypassed by a diode.

Switching Characteristics

Switching time depends upon load resistance — RE — and pullup voltage VC. Typical ON and OFF switching times for RE: 1kΩ and VC: 30V are less than 30 µs.

The following table defines plug connection/Data line definition for both ND810 and ND811:

Data bit DXi/DXo Burndy plug pins
D0/D0o A/C
D1/D1o B/D
D2/D2o E/H
D3/D3o F/J
D4/D4o K/M ND810
D5/D5o L/N and
D6/D6o P/S ND811
D7/D7o R/T
D8/D8o U/W
D9/D9o V/X
D10/D10o Y/AA
D11/D11o Z/BB
D12/D12o ZZ/EE
D13/D13o DD/FF ND811 only
D14/D14o HH/KK
D15/D15o JJ/LL
      +---------------------------------+
      |                                 |
  ND  |     Bergen, tel. 05-292290      |    ND 
      |     Sandnes, tel. 06-541564     |    COMTEC
  Da  |     Tromso, tel. 083-71716      |
      |     Stockholm, tel. 08-235065   |    Jerikoveien 20    
      |       tix. 13528 nordata s      |    Boks 4 Lindeberg gard
  Tele|     Goteborg, tel. 031-259554   |    Oslo 10    
      |     Malmo, tel. 040-191250      |    Tel: 02-39030     
  kern|     Copenhagen, tel. 01-259055  |    Tlx: 18664 nd n   
      |       tix. 37725 nd dk          |
      |     Wedschweid, tel. 06151-7541 |    Trondheim, tel. 075-16250, tix. 55580 comtec n
      |       tix 415570 nd ga          |    Stockholm (Upplands Vasby), tel. 08-25030, tix. 13528 nordata s
      |     Paris, tel. 01-234566       |    Stockholm (Solna), tel. 08-275855, tix. 13700 swecom s
      |     Lyon, tel. 78-632347        |    Odense, tel. 09-157044, tix. 65868 comtec dk
      |     Newberry (Norfolk), tel. 0635-31465 |    Ballerup (Copenhaven), tel. 02-678100
  Bosto|     Boston, tel. 061-2377945,  |    Dusseldorf, tel. 0211-663638, tix. 8557277 comt d
      |       tix 921750 norsk weil     |
      |                                 |
      +---------------------------------+

Note: NORSK DATA reserves the right to change specifications without given notice!