Introduction

The ND 567 – DMA CONTROLLER – is designed to take care of all address decoding, Requests, Interrupts and acting as an interface between the standard I/O Bus and a local data bus. The module is used for all Norsk Data DMA devices as disks and MagTapes.

The module occupies only one standard I/O slot and is always used together with either the DMA Receiver 1014 or the Buffered DMA Receiver 1092 modules.

Features

  • IOX Address Decoding
  • DMA Request and Grant Control Logic
  • DMA and Error Interrupt Control
  • Control of Memory Address Register
  • Used by all standard Norsk Data DMA equipment

Product Description

The ND 567 may be put into any standard I/O position and is the only module of a DMA interface/controller which is on the I/O Bus.

The remaining part of a DMA interface/controller is normally at the end of the I/O crate.

The main functions of the ND 567 are to take care of the communication with the I/O Bus and to handle most of the control functions associated with a DMA device.

          +-----------------------------------------------+
          |                    FLAT CABLE                 |
          +-----------------------------------------------+
+----------+-------------------+-------------------+----------------+ 
| BUS      |                   |                   |                |
| RECEIVER |                   |                   |   DMA          |
| ND 163   |    STANDARD I/O   |                   |   CONTROLLER   |
|          |        BUS        |                   |                |
|          |                   |                   |                |
+----------+-------------------+-------------------+----------------+
       |                                                              
       v                                                              
   1014 or                                                           
   1096 MODULE                                                       

Page 2

ND 587 DMA CONTROLLER

Introduction

The ND 587 - DMA CONTROLLER - is designed to take advantage of modern computer design and to optimize the handling of tasks managed by the ND CPU and I/O system.

Product Description

  • [Illegible text]
  • [Illegible text]
 _______________________
|                       |
|     DMA CONTROLLER    |
|_______________________|
|                       |
|    BUS INTERFACE      |
|_______________________|

Contact Information

Company Address Telephone
NORSK DATA A.S Lindbergvn. nord 20, Box 4 - Lindeberg gård, Oslo 10, NORWAY Tel. 02-391601, Tlx. 18661 nd n
NORSK DATA ApS Øverødvej 5, 2840 Holte, DENMARK Tel. 02425055
NORSK DATA DEUTSCHLAND Abraham-Lincoln-Str. 30, 6200 Wiesbaden, WEST GERMANY Tel. 06121-764220, Tlx. 4186370 noda
ND NORSK DATA AB Kanalvägen 3, Box 2031, 194 02 Upplands Väsby, SWEDEN Tel. 076-86500, Tlx. 13528 nordata s
ND NORSK DATA AB Käringfästgatan 11, Box 9052, 421 09 Västra Frölunda, SWEDEN Tel. 031-299350
NORSK DATA FRANCE "Le Brevent", Avenue du Jura, 01210 Ferney-Voltaire, FRANCE Tel. 050-408576, Tlx. 385653 nordata ferny
NORSK DATA FRANCE 120 Bureau de la Colline, 92213 Saint Cloud, FRANCE Tel. 01-6023367, Tlx. 201108 nd paris
NORSK DATA N.A., Inc. 65 William Street, Wellesley, Mass. 02181, USA Tel. 0617-237.7945
RICHARD NORTON (NORD) Ltd. NORD House, 17 Balfe Street, King's Cross, London N1 9EB, ENGLAND Tel. 01-2785501, Tlx. 299537

Note: Norsk Data reserves the right to change specifications at any time without given notice!