Page 1¶
ND163 BUS RECEIVER¶
Introduction¶
The ND163 – BUS RECEIVER – controls the use of the standard I/O Bus for CPU controlled interfaces and DMA controllers. The ND163 also serves as a branch point and a buffer/driver for the interfaces/controllers in the BUS RECEIVERS' associated LOCAL I/O BUS.
ND174 – 16 MEMORY ADDRESS REGISTERS – contain 16 16 bit Memory Address Registers which are used by the DMA devices communicating on the LOCAL I/O BUS.
Features¶
- Simple interfacing to LOCAL I/O BUS
- 3-state LOCAL I/O BUS for increased speed
- 4 layer printed circuit back-plane for increased noise immunity
- LOCAL I/O BUS provides separate bidirectional 16 bit data and 18 bit address lines for increased performance
- 4 classes of vectored I/O interrupts and one level of DMA interrupt
Diagram¶
graph TB
A(MAIN I/O BUS from CPU/previous ND163)
classDef default className fill:#fff,stroke:#333,stroke-width:1px;
subgraph "BUFFER/DRIVERS"
direction LR
B[Data 16]
C[Addr 18]
D[Contr. 13]
end
E[16 LOCAL I/O BUS]
F[18]
G[16]
A --> B --> E
A --> C --> F
A --> D --> G
class B,C,D fill:#eee,stroke:#333;
class E,F,G fill:#eee,stroke:#333;
H(ND 163 - BUS Receiver)
E --> H
F --> H
G --> H
subgraph "LOGICAL CONFIGURATION"
direction TB
I(MAIN I/O BUS to next ND163)
end
163–B1–1800–0179
Scanned by Jonny Oddene for Sintran Data © 2010
Page 2¶
Product Description¶
Physically, the ND163 — BUS RECEIVER — consists of a 19" rack with a printed circuit back-plane to accommodate the BUS RECEIVER, the ND174 – 16 Memory Address Registers, the ND164 – Bus Brancher and 8 I/O slots. By adding a ND169 — Bus Extender, 8 additional I/O slots are available.
The BUS RECEIVER may drive up to 16 I/O interfaces/ DMA controllers and 8 positions are always reserved for a DMA controller. The BUS RECEIVER can control both CPU controlled and DMA transfers.
Specifications¶
| Specification | Details |
|---|---|
| Maximum number of I/O slots | 16 (requires an additional ND169) |
| Main I/O Bus | Differential lines |
| Local I/O Bus | - 3-state - 18 address lines - 16 data lines - 16 control lines (includes 5 interrupt lines) |
Main I/O Bus to/from CPU or Bus Receiver (Differential lines)
|
|
+--------------------------|---------------------------------------------------
| |
| |
⇓ | Local I/O Bus
Add Data Contr. |
+---+---+---+---+---+---+-----------|----+---+---+---+---+---+---+---+---+---+---+---+---
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | | 9 |10 |11 |12 |13 |14 |15 |16 |17 |18 |19 |20 |21 |22 |23 |24 |
+---+---+---+---+---+---+---+---+---|----+---+---+---+---+---+---+---+---+---+---+---+---+
| | | | | | | |
| | | | | | *---------|----------------------------------------------+
| | | | | *-------------|------------------------------------------+ |
| | | | *-----------------|-------------------------------------+ | |
| | | *---------------------|------------------------------+ | | |
| | *-------------------------|-------------------------+ | | | |
| *-----------------------------|--------------------+ | | | | |
*---------------------------------|-------------+ | | | | | |
DMA Data | | | | |
Addr. ⇓ | | | | |
**ND174: ┌----┐ | | | | |
M. Addr** | | | | | | |
Reg | | | ⇓ | | |
| | +----^. | | |
| | | | | | |
└----┘ | | | | |
*--*| | | |
| | | |
+---+------|----+---+---+
ND164: Bus Brancher Data - 1093
ND174: 16 Memory Address Registers 1096
8 I/O Slots
ND169 Bus Extender
- Reserved for any Data
Channel Controller
Contact Information¶
| Company | Address/Contact Info |
|---|---|
| NORSK DATA A.S | Lindebergsvn. nord 20, Box 4 - Lindeberg gård Oslo 10, NORWAY Tel. 02-391601, Tlx. 18661 nd n |
| NORSK DATA A/S | Øverødvej 5 2840 Holte, DENMARK Tel. 02-425055 |
| NORSK DATA DEUTSCHLAND | Abraham-Lincoln-Str. 30 6200 Wiesbaden, WEST GERMANY Tel. 06121-764220, Tlx. 4186370 noda |
| ND NORSK DATA AB | Kanalvagen 3, Box 2031 194 02 Upplands Väsby, SWEDEN Tel. 076-86500, Tlx. 13528 nordata s |
| NORSK DATA FRANCE | "Le Brevent", Avenue du Jura 1210 Ferney-Voltaire, FRANCE Tel. 050-408576, Tlx. 385653 nordata fernv |
| ND NORSK DATA AB | Klangfärgsgatan 11, Box 9052 421 09 Västra Frölunda, SWEDEN Tel. 031-299350 |
| NORSK DATA FRANCE | 120 Bureau de la Colline 92213 Saint Cloud, FRANCE Tel. 01-6023367, Tlx. 210108 nd paris |
| NORSK DATA N.A., Inc. | 65, William Street Wellesley, Mass. 02181, USA Tel. 0617-237-7945 |
| RICHARD NORTON (NORD) Ltd. | NORD House, 17 Balfre Street, King's Cross London N1 9EB, ENGLAND Tel. 01-2785501, Tlx. 299537 |
NOTE: Norsk Data reserves the right to change specifications at any time without given notice!