Skip to content

Page 1

I/O LINE SWITCH

ND 9101/9102/9103/9104

   _______________________________________________________
  |                                                       |
  |                    I/O Line Switch                     |
  |_______________________________________________________|
  |                                                       |
  |                                                     o |
  |                                                    T  |
  |                                                    E  |
  |                                                    L  |
  |                                                    E  |
  |             ______________________________________    |
  |            |          DUAL POWER SUPPLY            |  |
  |            |______________________________________ |  |
  |                                                       |
  |            ______________________________________     |
  |           |        SWITCH MODULE CRATE 1         |    |
  |           |______________________________________|    |
  |                                                       |
  |           |                                         | |
  |          S|                                      T  | |
  |          W|                                      E  | |
  |          I|                                      L  | |
  |          T|                                      E  | |
  |          C|                                      C  | |
  |          H|             SWITCH MODULES 1-16       | |
  |           |_______________________________________| |
  |                                                       |
  |            ________________________________________   |
  |           |               PLUG PANEL ADAPTORS     .|  |
  |           |______________________________________  |  |
  |                                                       |
  |            ______________________________________     |
  |           |        SWITCH MODULE CRATE 2         |    |
  |           |______________________________________|    |
  |                                                       |
  |           |                                         | |
  |          S| DUAL                                   C | |
  |          W|                                          | |
  |          I|         SWITCH MODULES 1-16             | |
  |          T|_________________________________________| |
  |          C|                                           |
  |          H|                                          T|
  |           |___________________________________________|
  |________________________________[R|U|M_________________|

ND Norsk Data


Scanned by Jonny Oddene for Sintran Data © 2010


Page 2

I/O LINE SWITCH

INTRODUCTION

Norsk Data's I/O Line Switch is a two-way switch for RS-232, current-loop or parallel interfaces. This means that in case of computer failure, or if necessary for other reasons, the peripherals and communication lines can be switched from the failing machine to the active one. Switching may be either manual or automatic (software controlled).

  A     B
  |     |
  +-----+
        |
  Terminal, printer or communication line

FEATURES

  • Direct connection to two separate computers
  • Possibility for switching the devices individually or in combination
  • High availability
  • High MTBF
  • Dual power supply

PRODUCT DESCRIPTION

The I/O Line Switch system consists both of hardware and of a software module, the Line Switch manager.

The Line Switch manager is the operator's command interface to the I/O Line Switch, and allows for automatic switching of the I/O lines.

The I/O Line Switch takes care of the physical switching, and consists of several switching devices, known as switch modules.

There are three types of switch modules:

  1. Switch module for current-loop lines.

    • Up to four current-loop lines (e.g. terminals or printers) per module can be connected.
  2. Switch module for RS-232 lines.

    • Up to two RS-232 lines (e.g. terminals, printers or PCs) per module can be connected.
  3. Switch module for HDLC or parallel lines.

    • One HDLC or megalink communication line, or one parallel line (e.g. high-speed printer) per module can be connected.

The I/O line switch consists of one or two cabinets containing switch modules that are mounted on one or two crates. There can be a maximum of two switch crates per cabinet. Each crate has room for up to 16 switch modules. This means that the total number of lines per cabinet is maximum:

Type Calculation Lines
For only current-loop 4 x 16 x 2 128
For only RS-232 2 x 16 x 2 64
For only HDLC or parallel 1 x 16 x 2 32

Any combination of these lines is allowed.


Page 3

I/O LINE SWITCH

 ________________________________________
|                                        |
|               Power supply             |
|________________________________________|
|                                        |
|                                        |
|[Maximum]                               |
| [two]    |---------------------|       |
| [switch] |                     |       |
| [crates] |                     |       |
|          |                     |       |
|          |                     |       |
|          |                     | [Maximum  |
|          |                     |  16       |
|          |                     |  switch   |
|          |                     |  modules] |
|          |                     |           |
|__________|_____________________|__________|
|                                        |
|            Power supply                |
|________________________________________|
|                                        |
|            Plug panels                 |
|________________________________________|

CONFIGURATIONS

Model Description
ND-9101 I/O line switch, 1 crate, 1 cabinet
(Up to 16 switch modules.)
ND-9102 I/O line switch, 2 crates, 1 cabinet
(Up to 32 switch modules.)
ND-9103 I/O line switch, 3 crates, 2 cabinets
(Up to 48 switch modules.)
ND-9104 I/O line switch, 4 crates, 2 cabinets
(Up to 64 switch modules.)
ND-210873 I/O line switch manager SW
ND-106900 Switch module for current loop lines
(Up to 4 lines per module.)
ND-106930 Switch module for RS-232 lines
(Up to 2 lines per module.)
ND-106940 Switch module for HDLC or parallel lines
(1 line per module.)

UPGRADING

  • ND-9105 Upgrade from 9101/9102 to 9103/9104.
  • ND-9106 Upgrade from 9102 to 9103.

REQUIREMENTS

  • One RS-232 line from each computer is used to control the switch.

TECHNICAL SPECIFICATIONS

Power Requirements:

  • Voltage: 220-240V Nominal
  • Frequency: 50 ± 5 Hz
  • Power Input: 100W
  • Operating Temperature: +10°C to +30°C
  • Operating Humidity: 20% - 80%
  • Weight (approximately): 80 kg

DOCUMENTATION

  • FTX Operator Manual ............................. ND-30.051 EN
  • Dynatech Manual - "DPS" Multifunctional
  • Patchswitch Manual ............................. GML 1000006

Scanned by Jonny Oddene for Sintran Data © 2010


Page 4

Norsk Data

Corporate Headquarters

Olaf Helsets vei 5
P.O. Box 25, Bogerud
0617 Oslo 6
Norway
Tel.: +47-2-620000
Telex: 738-2477572
Telefax: +47-2-282946 (A)

Norway

Oslo: Tel. +47-2-390200
Bergen: Tel. +47-5-965100
Sandnes: Tel. +47-2-817600
Trones: Tel. +47-7-397786
Trondheim: Tel. +47-9-161262

ND Comtec Head Office

Olaf Helsets vei 5
P.O. Box 25, Bogerud
0217 Oslo 6
Norway
Tel.: +47-2-620000
Telex: 14446 nd n
Telefax: +47-2-267496 (A)

Sweden

ND Norsk Data AB
Kanalvägen 3
P.O. Box 21
191 27 Upplands Väsby
Sweden
Tel.: +46-8-980400
Telex: 15575 ndaba s
Telefax: +46-780-2587 (A)

Gothenburg: Tel. +46-31-693670
Malmö: Tel. +46-40-76010

ND-Silvidata Sweden

881 88 Sundsvall
Sweden
Tel.: +46-60-151450
Vaxjo: Tel. +46-470-49200
Stockholm: Tel. +46-708-52000

Denmark

Norsk Data A S
Lautrupv B 1-3
P.O. Box 230
2750 Ballerup
Denmark
Tel.: +45-42-686555
Telex: 47266 nd d
Telefax: +45-1-88-7264 (A)

Copenhagen: Tel. +45-1-888864
Arhus: Tel. +45-6-122505

Finland

ND Norsk Data Ab
Vapaalantie 8 (Vanda)
01300 Helsinki
Tel.: 360-98-556-022
Telex: 0057-12132 ppafy sf

West Germany

Norsk Data GmbH
Thomastraße 10-12
6304
Bad Homburg v.d.H.
West Germany
Tel.: +49 6172-48000
Telex: 04 11-75558 nd d
Telefax: 49172-2290 (A)

West Berlin: Tel. +30-213-9306
Hamburg: Tel. +49-40-823082
Hannover: Tel. +49-511-411121
Mühlheim: Tel. +49-208-131625
Stuttgart: Tel. +49-711-393100

The Netherlands

Norsk Data Nederland B.V
Brugwal 5
P.O. Box 50
3430 AM Nieuwegein
The Netherlands
Tel.: +31-340-72411
Telex: 49030 and nd nl

France

Norsk Data S.a r.l
25 Rue d’Ida
Avenue De Jura
01170 Cessy-Village
France
Tel.: +33-50-40258
Telex: 330652 norkom f
Telefax: +33-50-438643 (A)

United Kingdom

Norsk Data Ltd.
Neneh Way
Newbury V C
Berkshire RG16 6UB
United Kingdom
Tel.: +44-6-35544
Telex: 844192 ndsd g
Telefax: +44-635-3367 (A)

London: Tel. +44-586-9955
Manchester: Tel. +44-61-681-5787
Edinburgh: Tel. +44-031-668-1681

USA

Norsk Data N.A., Inc.
56 Williams Street
Wellesley Street 02181
USA
Tel.: +1-617-237-1395
Telex: 921307 ndcs well
Telefax: +1-617-237-9135 (A)

Los Angeles: Tel. +1-714-752-5081

Hong Kong

Norsk Data Hong Kong Ltd.
1101 Wing On Centre
111 Connaught Road
Central Hong Kong
Tel.: 8520-5112819/5110253
Telex: 63508 ndh g
Telefax: 8520-5112101

Represented by Agent In:

  • India: Norsk Data (India), Ltd. Tel.: 91-44-491717/491713, 85 A. 17/200 Canton S
  • Thailand: Norsk Data (Thai), Ltd. Tel.: +62-2-253-4880, Nokdee 2081 and Nonthaburi c nd
  • France and Italy:
    • S.A. Paris: Tel.: 33-950602, Ski Lyon: +33-4841300, Tel. +33-904539 nd alpha
    • Madrid: Tel.: 33-953050, 6-3513220 mdafat ch, Tel. +33-348477037 md lyon
    • Toulouse: Tel.: +33-61-342400, bb 530290