ND164 BUS BRANCHER

INTRODUCTION

The ND164 — BUS BRANCHER — is designed to be a high performance data channel which is connected to an independent memory port on the ND140 — MULTIPORT MEMORY SYSTEM. The BUS BRANCHER provides high speed data transfers to take place to memory — independently of the CPU.

FEATURES

  • Separate high speed, 18 bit data channel with 256K words address space
  • No cycle steal from CPU
  • The BUS BRANCHER may be installed in any BUS RECEIVER (ND163) to provide a separate high speed data channel
  • Parity checked transfers

PRODUCT DESCRIPTION

Prerequisites for the BUS BRANCHER (ND164) are the ND163 — Bus Receiver, the ND174 — 16 Memory Address Registers, and a separate memory port — ND141 — in the Multiport Memory System.

When the BUS BRANCHER is installed in the available slot in the BUS RECEIVER, 18 bit data lines, 18 bit address lines and 3 control lines are available on separate connectors constituting the high speed data channel. The only cabling required are the two channel cables going to the separate memory port in the Multiport Memory System.

All transfers on the high speed data channel are parity checked. In event of parity error, the processor will be notified and two parity error indicators on the BUS BRANCHER (for least and most significant byte) will be activated.

Diagram

    +----------------+
    |      Bank X    |
    | +----+----+    |
    | |ND141|ND141|  |
    +----------------+
         |     |
         |     | ND140
         |     |
    +------------+
    |   NORD-10/S |
    +------------+
         |     |
     +---+     +---+
     |             |  
  +--v--+       +--v--+
  | BR  |       | BR  |
  | ND174|      | ND174|
  | ND164|      | ND164|
  +------|      +------|
  | Local|      | Local|
  | I/O  |      | I/O  |
  | Bus  |      | Bus  |
  +------+      +------+

164–B1–1800–0179

Scanned by Jonny Oddene for Sintran Data © 2010


Page 2

Diagram

flowchart TB
    io_main[MAIN I/O BUS]
    io_main -->|Address| io_main_end1[ ]
    io_main -->|Data| io_main_end2[ ]
    io_main -->|Control| io_main_end3[ ]

    subgraph modules
        ND174[ND174<br>Address<br>Register]
        ND174 -->|Driver| control[Control]

        ND163[ND163<br>Bus<br>Receiver]
        ND163 --> MPM[MPM<br>Enable]

        ND164[ND164<br>Bus Brancher]

        MPM -->|Driver| modules_end

        control --> modules_end
    end

    hDMA[High speed<br>DMA Channel]

    hDMA -->|Write| io_main_end1
    hDMA -->|Request| io_main_end1
    hDMA -->|Address| ND174
    hDMA -->|Data| io_main_end2
    hDMA -->|Data ready| io_main_end2

    io_main_end1 --> ND164
    io_main_end2 --> ND164
    io_main_end3 --> ND164

Specifications

Specification Details
Channel transfer rate 1.6 Mbytes /second
Parity Parity per byte — odd parity
Channel address space 256 Kwords (16 bit words)

Contact Information

Company Address Telephone
NORSK DATA A.S Lindebergvn, road 20, Box 4 - Lindeberg gård
Oslo 10, NORWAY
Tel. 02-391601, Tlx. 18661 nd n
NORSK DATA ApS Øverødvej 5
2840 Holte, DENMARK
Tel. 02425055
NORSK DATA DEUTSCHLAND Abraham-Lincoln-Str. 30
6200 Wiesbaden, WEST GERMANY
Tel. 06121-764220, Tlx. 4186370 noda
ND NORSK DATA AB Kanalvägen 3, Box 2031
194 02 Upplands Väsby, SWEDEN
Tel. 076-86500, Tlx. 13528 nordata s
NORSK DATA FRANCE "Le Brevent", Avenue du Jura
01210 Ferney-Voltaire, FRANCE
Tel. 050-408576, Tlx. 385653 nordata fernv
NORSK DATA N.A., Inc. 65, William Street
Wellesley, Mass. 02181, USA
Tel. 0617-237.7945
ND NORSK DATA AB Klangfärgsgatan 11, Box 9052
421 09 Västra Frölunda, SWEDEN
Tel. 031-299350
NORSK DATA FRANCE 120 Bureau de la Colline
92213 Saint Cloud, FRANCE
Tel. 01-6023367, Tlx. 201108 nd paris
RICHARD NORTON (NORD) Ltd. NORD House, 17 Balfe Street, King's Cross
London N1 9EB, ENGLAND
Tel. 01-2785501, Tlx. 299537

NOTE: Norsk Data reserves the right to change specifications at any time without given notice!