Skip to content

Page 1

ND 138/892 MOS MEMORY POWER

INTRODUCTION

The MOS Memory Power unit is designed to be an integral part of a ND cabinet and will deliver all necessary power and voltages to the Norsk Data produced equipment which may typically be mounted inside such a cabinet. The power unit also has a battery back-up capability as standard.

The power unit exists in two versions where the only difference is the input line voltage and frequency that the unit will accept, i.e. 220V/50 Hz, 115V/60 Hz.

FEATURES

  • Input voltage:
    • 220V, 50 Hz (ND 138)
    • 115V, 60 Hz (ND 892)
  • Overvoltage protection
  • Output voltages for all processors, memory and Input/Output
  • Output current limitation
  • Meets the IEC 68 and the IEC 485 class 1 requirements

PRODUCT DESCRIPTION

The unit is controlled and diagnosed by means of a front panel which contains the following:

  • Power switch and Input Line Connector
  • Input Fuse
  • Status lamps and Margin controls
  • Voltage adjustable potentiometers
  • Power-on time meter

There is a remote power-on control feature that can be used when several cabinets and power units are used in one system. The unit has overvoltage and current limiting protection circuits such that no special operational precautions are necessary. However, environmental specifications must be followed.

138/892–A2–1000–0681

[Photo: Front panel of NORD POWER UNIT 10S]


Page 2

SPECIFICATIONS

Electrical Characteristics

Mains Input
220V +/- 10%, 50 Hz +/- 1%
115V +/- 10%, 47-65 Hz

Load
Max. 7A/220V
Max. 13A/115V

Instantaneous power-on surge
Max. 100A in 10 ms

AC Output

115V/230V for fans and auxiliary. Maximum 3.5A.

DC Output

  • +5V, either 100A or 150A for logic
  • +5V, 8A, stand-by for memory
  • +12V, 70mA, stand-by for memory
  • +12V, 2A, stand-by for memory
  • +24V, 5A for I/O interfaces and Floppy Disk
  • -5V, 500 mA for Floppy Disk

Environmental

Temperature
Storage: -40 to +70°C
Operating: 0 to +50°C with forced air cooling

Meets the IEC 68 (Test procedures) and the IEC 485 (Safety of data processing equipment) class 1 requirements.

MTBF
35,000 hours

MTTR
1 hour

Mechanical

Mounting
19” rack mountable on special brackets

Width 430 mm
Depth 586 mm
Height 163 mm
Weight 32 kg

[Logo: Norsk Data]

[Logo: ND COMTEC]

NOTE: NORSK DATA reserves the right to change specifications without given notice!